TOF MLEM Adaptation for the Total-Body J-PET With a Realistic Analytical System Response Matrix

被引:2
|
作者
Shopa, R. Y. [1 ]
Baran, J. [2 ,3 ,4 ]
Klimaszewski, K. [1 ]
Krzemien, W. [3 ,5 ,6 ]
Raczynski, L. [1 ]
Wislicki, W. [1 ]
Brzezinski, K. [7 ]
Chug, N. [2 ,3 ,4 ]
Coussat, A. [2 ,3 ,4 ]
Curceanu, C. [8 ]
Czerwinski, E. [2 ,3 ,4 ]
Dadgar, M. [2 ,3 ,4 ]
Dulski, K. [2 ,3 ,4 ]
Gajewski, J. [7 ]
Gajos, A. [2 ,3 ,4 ]
Hiesmayr, B. C. [9 ]
Valsan, E. Kavya [2 ,3 ,4 ]
Korcyl, G. [2 ,3 ,4 ]
Kozik, T. [2 ,3 ,4 ]
Kumar, D. [2 ,3 ,4 ]
Kaplon, L. [2 ,3 ,4 ]
Moskal, G. [3 ,4 ,10 ]
Niedzwiecki, S. [2 ,3 ,4 ]
Panek, D. [2 ,3 ,4 ]
Parzych, S. [2 ,3 ,4 ]
Rio, E. Perez del [2 ,3 ,4 ]
Rucinski, A. [7 ]
Sharma, S. [2 ,3 ,4 ]
Shivani, S. [2 ,3 ,4 ]
Silarski, M. [2 ,3 ,4 ]
Skurzok, M. [2 ,3 ,4 ]
Stepien, E. [2 ,3 ,4 ]
Ardebili, F. Tayefi [2 ,3 ,4 ]
Ardebili, K. Tayefi [2 ,3 ,4 ]
Moskal, P. [2 ,3 ,4 ]
机构
[1] Natl Ctr Nucl Res, Dept Complex Syst, PL-05400 Otwock, Poland
[2] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, PL-31007 Krakow, Poland
[3] Jagiellonian Univ, Total Body Jagiellonian PET Lab, PL-31007 Krakow, Poland
[4] Jagiellonian Univ, Ctr Theranost, PL-31007 Krakow, Poland
[5] Jagiellonian Univ, Ctr Theranost, PL-31007 Krakow, Poland
[6] Natl Ctr Nucl Res, Div High Energy Phys, PL-05400 Otwock, Poland
[7] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[8] INFN, Lab Nazl Frascati, I-00044 Frascati, Italy
[9] Univ Vienna, Fac Phys, A-1090 Vienna, Austria
[10] Jagiellonian Univ, Fac Chem, PL-31007 Krakow, Poland
关键词
Positron emission tomography; Detectors; Photonics; Sensitivity; Scintillators; Cathode ray tubes; Strips; Jagiellonian positron emission tomography (PET); maximum-likelihood expectation-maximization (MLEM); medical imaging; nuclear medicine; PET; system response matrix (SRM); total-body (TB) PET; IMAGE-RECONSTRUCTION; PLASTIC SCINTILLATOR; SIMULATION; RESOLUTION; EMISSION;
D O I
10.1109/TRPMS.2023.3243735
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum-likelihood expectation-maximization (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multilayer layouts and is extendable to multiphoton imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for time-of-flight (TOF), parallax effect, and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static extended cardiac-torso phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images, and ground-truth metrics. We also reconstructed the data with additive contributions, prefiltered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalize on the realistic RM with better edge preservation and superior ground-truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multiphoton imaging and further upgrade to account for the noncollinearity, positron range, and other factors.
引用
收藏
页码:509 / 520
页数:12
相关论文
共 32 条
  • [21] Performance of a new preclinical PET/CT system for quantitative total-body dynamic imaging with low tracer doses
    Molinos, Cesar
    Eigner, Sebastian
    Sasser, Todd
    Viertl, David
    Berr, Stuart
    Kundu, Bijoy
    Gsell, Willy
    Bahadur, Ali
    Stark, Simon
    Correcher, Carlos
    van Wyk, Susanna
    Prior, John
    Himmelreich, Uwe
    Heidenreich, Michael
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2019, 62 : S425 - S426
  • [22] The perfusion response to adenosine in the brain, liver, spleen, kidneys, skeletal muscles, and pancreas as measured using total-body PET
    Karpijoki, H.
    Tuisku, J.
    Palonen, S.
    Nesterov, S.
    Maaniitty, T.
    Saraste, A.
    Nummenmaa, L.
    Knuuti, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S416 - S417
  • [23] Nasopharyngeal Carcinoma Tumor Segmentation with Multimodal Cross-Attention Transformer on Total-Body uEXPLORER PET/CT System
    Zhao, Wenjie
    Huang, Zhenxing
    Tang, Si
    Hu, Ying-ying
    Fan, Wei
    Li, Wenbo
    Gao, Yunlong
    Yang, Yongfeng
    Liang, Dong
    Hu, Zhanli
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [24] Total-body 18F-FDG PET/CT in patients with inflammatory arthritis: initial findings using the uEXPLORER system
    Abdelhafez, Yasser
    Sarkar, Soumajyoti
    Hunt, Heather
    Mike Nguyen
    Caudle, Denise
    Nardo, Lorenzo
    Cherry, Simon
    Badawi, Ramsey
    Raychaudhuri, Siba
    Chaudhari, Abhijit
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [25] MMCA-NET: A Multimodal Cross Attention Transformer Network for Nasopharyngeal Carcinoma Tumor Segmentation Based on a Total-Body PET/CT System
    Zhao, Wenjie
    Huang, Zhenxing
    Tang, Si
    Li, Wenbo
    Gao, Yunlong
    Hu, Yingying
    Fan, Wei
    Cheng, Chuanli
    Yang, Yongfeng
    Zheng, Hairong
    Liang, Dong
    Hu, Zhanli
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (09) : 5447 - 5458
  • [26] Adequacy of whole-body parametric imaging of regional tissue perfusion using the recent total-body PET system and i.v. 15O-water
    Iida, H.
    Merisaari, H.
    Ono, N.
    Kudomi, N.
    Tolvanen, T.
    Saunavaara, V.
    Sari, H.
    Knuuti, J.
    Nummenmaa, L.
    Nuutila, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S110 - S110
  • [27] Partial volume effect and voxel noise along the one meter axial field-of-view of a total-body PET/CT system for multiple isotopes
    Mannheim, J. G.
    Schmidt, F. P.
    Rausch, I.
    Kupferschlaeger, J.
    La Fougere, C.
    Pichler, B. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S343 - S343
  • [28] Characterization of the partial volume effect along the axial field-of-view of the Biograph Vision Quadra total-body PET/CT system for multiple isotopes
    Julia G. Mannheim
    Ivo Rausch
    Maurizio Conti
    Christian la Fougère
    Fabian P. Schmidt
    EJNMMI Physics, 10
  • [29] Characterization of the partial volume effect along the axial field-of-view of the Biograph Vision Quadra total-body PET/CT system for multiple isotopes
    Mannheim, Julia G.
    Rausch, Ivo
    Conti, Maurizio
    la Fougere, Christian
    Schmidt, Fabian P.
    EJNMMI PHYSICS, 2023, 10 (01)
  • [30] Image quality assessment along the one meter axial field-of-view of the total-body Biograph Vision Quadra PET/CT system for 18F
    Rausch, I.
    Mannheim, J. G.
    Kupferschlaeger, J.
    la Fougere, C.
    Schmidt, F. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S189 - S189