Physical and digital phantoms for 2D and 3D x-ray breast imaging: Review on the state-of-the-art and future prospects

被引:17
作者
Sarno, Antonio [1 ,2 ]
Valero, Chiara [3 ]
Tucciariello, Raffaele M. [4 ]
Dukov, Nikolay [5 ]
Costa, Paulo R. [6 ]
Tomal, Alessandra [7 ]
机构
[1] Univ Napoli Federico II, Dept Phys E Pancini, Naples, Italy
[2] Univ Napoli Federico II, INFN Sez Napoli, Naples, Italy
[3] Azienda Osped Ordine Mauriziano, Med Phys Dept, Turin, Italy
[4] Ctr Riferimento Oncol Basilicata IRCCS CROB, Fis Sanit, Rionero In Vulture, Potenza, Italy
[5] Med Univ Varna, Dept Med Equipment Elect & Informat Technol Health, Varna, Bulgaria
[6] Univ Sao Paulo, Inst Fis, Sao Paulo, Brazil
[7] Univ Estadual Campinas, Inst Fis Gleb Wataghin, Campinas, SP, Brazil
关键词
Breast phantoms; Mammography; DBT; BCT; Additive manufacturing; Virtual clinical trials; MONTE-CARLO; COMPUTED-TOMOGRAPHY; SOFTWARE PHANTOM; TOMOSYNTHESIS; MAMMOGRAPHY; PERFORMANCE; CT; SIMULATION; DOSIMETRY; SYSTEMS;
D O I
10.1016/j.radphyschem.2022.110715
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Breast phantoms are a fundamental asset both in routine quality assurance programs and for comparing scanner performance in 2D and 3D x-ray breast imaging. They also play an essential role in the optimization of imaging systems and for testing new technologies before their introduction in the clinical practice. The ideal phantom must reflect and mimic the organ anatomy and pathologies, including details such as simulated tumor masses or microcalcifications. They can also be designed to evaluate a particular technical specification of the detector or of the imaging setup, such as noise or spatial resolution. The introduction of digital breast tomosynthesis (DBT) and computed tomography dedicated to the breast (BCT) in the clinical practice allowed to acquire 3D breast images with relatively high contrast and spatial resolution. The introduction of these innovative technologies encouraged the development of new phantoms for quality assurance and systems comparisons; on the other hand, 3D images of the breasts acquired with DBT and BCT apparatuses along with innovative and low-cost additive manufacturing technologies have been the basis for the development of a new class of digital and physical anthropomorphic breast phantoms. In these cases, the realism has been demonstrated to be fundamental in overtaking the limits of conventional phantoms used in digital mammography (DM) quality assurance programs. This work aims at reviewing the conventional phantoms adopted for testing and optimizing DM, DBT and BCT systems and to furnish a critical insight in emerging physical and digital breast phantoms. The limitations of conventional phantoms will be outlined, also regarding the needs of comparing apparatuses which adopt a compressed breast geometry to modern BCT ones, with pendant uncompressed breast geometry.
引用
收藏
页数:17
相关论文
共 165 条
[41]   Comparative power law analysis of structured breast phantom and patient images in digital mammography and breast tomosynthesis [J].
Cockmartin, L. ;
Bosmans, H. ;
Marshall, N. W. .
MEDICAL PHYSICS, 2013, 40 (08)
[42]   Comparison of digital breast tomosynthesis and 2D digital mammography using a hybrid performance test [J].
Cockmartin, Lesley ;
Marshall, Nicholas W. ;
Van Ongeval, Chantal ;
Aerts, Gwen ;
Stalmans, Davina ;
Zanca, Federica ;
Shaheen, Eman ;
De Keyzer, Frederik ;
Dance, David R. ;
Young, Kenneth C. ;
Bosmans, Hilde .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10) :3939-3958
[43]   Characterization of paraffin based breast tissue equivalent phantom using a CdTe detector pulse height analysis [J].
Cubukcu, Solen ;
Yucel, Haluk .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) :877-884
[44]   Stable gelatin-based phantom materials with tunable x-ray attenuation properties and 3D printability for x-ray imaging [J].
Dahal, Eshan ;
Badal, Andreu ;
Zidan, Ahmed ;
Alayoubi, Alaadin ;
Hagio, Tomoe ;
Glick, Stephen ;
Badano, Aldo ;
Ghammraoui, Bahaa .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09)
[45]   Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols [J].
Dance, D. R. ;
Young, K. C. ;
van Engen, R. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02) :453-471
[46]   Dosimetry in x-ray-based breast imaging [J].
Dance, David R. ;
Sechopoulos, Ioannis .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19) :R271-R304
[47]   Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol [J].
Dance, DR ;
Skinner, CL ;
Young, KC ;
Beckett, JR ;
Kotre, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3225-3240
[48]   Anthropomorphic Physical Breast Phantom Based on Patient Breast CT Data: Preliminary Results [J].
Daskalov, Sivo ;
Okkalidis, Nikiforos ;
Boone, John M. ;
Marinov, Stoyko ;
Bliznakov, Zhivko ;
Mettivier, Giovanni ;
Bosmans, Hilde ;
Russo, Paolo ;
Bliznakova, Kristina .
XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 :367-374
[49]   GEANT4 Monte Carlo simulations for virtual clinical trials in breast X-ray imaging: Proof of concept [J].
di Franco, F. ;
Sarno, A. ;
Mettivier, G. ;
Hernandez, A. M. ;
Bliznakova, K. ;
Boone, J. M. ;
Russo, P. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 :133-142
[50]  
di Franco F., 2019, 2019 IEEE NUCL SCI S, P1