Physical and digital phantoms for 2D and 3D x-ray breast imaging: Review on the state-of-the-art and future prospects

被引:14
作者
Sarno, Antonio [1 ,2 ]
Valero, Chiara [3 ]
Tucciariello, Raffaele M. [4 ]
Dukov, Nikolay [5 ]
Costa, Paulo R. [6 ]
Tomal, Alessandra [7 ]
机构
[1] Univ Napoli Federico II, Dept Phys E Pancini, Naples, Italy
[2] Univ Napoli Federico II, INFN Sez Napoli, Naples, Italy
[3] Azienda Osped Ordine Mauriziano, Med Phys Dept, Turin, Italy
[4] Ctr Riferimento Oncol Basilicata IRCCS CROB, Fis Sanit, Rionero In Vulture, Potenza, Italy
[5] Med Univ Varna, Dept Med Equipment Elect & Informat Technol Health, Varna, Bulgaria
[6] Univ Sao Paulo, Inst Fis, Sao Paulo, Brazil
[7] Univ Estadual Campinas, Inst Fis Gleb Wataghin, Campinas, SP, Brazil
关键词
Breast phantoms; Mammography; DBT; BCT; Additive manufacturing; Virtual clinical trials; MONTE-CARLO; COMPUTED-TOMOGRAPHY; SOFTWARE PHANTOM; TOMOSYNTHESIS; MAMMOGRAPHY; PERFORMANCE; CT; SIMULATION; DOSIMETRY; SYSTEMS;
D O I
10.1016/j.radphyschem.2022.110715
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Breast phantoms are a fundamental asset both in routine quality assurance programs and for comparing scanner performance in 2D and 3D x-ray breast imaging. They also play an essential role in the optimization of imaging systems and for testing new technologies before their introduction in the clinical practice. The ideal phantom must reflect and mimic the organ anatomy and pathologies, including details such as simulated tumor masses or microcalcifications. They can also be designed to evaluate a particular technical specification of the detector or of the imaging setup, such as noise or spatial resolution. The introduction of digital breast tomosynthesis (DBT) and computed tomography dedicated to the breast (BCT) in the clinical practice allowed to acquire 3D breast images with relatively high contrast and spatial resolution. The introduction of these innovative technologies encouraged the development of new phantoms for quality assurance and systems comparisons; on the other hand, 3D images of the breasts acquired with DBT and BCT apparatuses along with innovative and low-cost additive manufacturing technologies have been the basis for the development of a new class of digital and physical anthropomorphic breast phantoms. In these cases, the realism has been demonstrated to be fundamental in overtaking the limits of conventional phantoms used in digital mammography (DM) quality assurance programs. This work aims at reviewing the conventional phantoms adopted for testing and optimizing DM, DBT and BCT systems and to furnish a critical insight in emerging physical and digital breast phantoms. The limitations of conventional phantoms will be outlined, also regarding the needs of comparing apparatuses which adopt a compressed breast geometry to modern BCT ones, with pendant uncompressed breast geometry.
引用
收藏
页数:17
相关论文
共 165 条
  • [21] Bliznakova K., 2012, J BIOMED GRAPH COMPU, V2, P1, DOI [DOI 10.5430/JBGC.V2N1P1, 10.5430/jbgc.v2n1p1]
  • [22] Bliznakova K, 2016, SCRIPTA SCIENTIFICA, V2, P23
  • [23] Bliznakova K., 2020, 2020 INT C E HLTH BI, P1
  • [24] The advent of anthropomorphic three-dimensional breast phantoms for X-ray imaging
    Bliznakova, Kristina
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 145 - 161
  • [25] Development of breast lesions models database
    Bliznakova, Kristina
    Dukov, Nikolay
    Feradov, Firgan
    Gospodinova, Galja
    Bliznakov, Zhivko
    Russo, Paolo
    Mettivier, Giovanni
    Bosmans, Hilde
    Cockmartin, Lesley
    Sarno, Antonio
    Kostova-Lefterova, Desislava
    Encheva, Elitsa
    Tsapaki, Virginia
    Bulyashki, Daniel
    Buliev, Ivan
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 293 - 303
  • [26] Validation of a mammographic image quality modification algorithm using 3D-printed breast phantoms
    Boita, Joana
    Mackenzie, Alistair
    van Engen, Ruben E.
    Broeders, Mireille
    Sechopoulos, Ioannis
    [J]. JOURNAL OF MEDICAL IMAGING, 2021, 8 (03)
  • [27] Two-dimensional breast dosimetry improved using three-dimensional breast image data
    Boone J.M.
    Hernandez A.M.
    Seibert J.A.
    [J]. Radiological Physics and Technology, 2017, 10 (2) : 129 - 141
  • [28] Technical Note: Noise models for virtual clinical trials of digital breast tomosynthesis
    Borges, Lucas R.
    Barufaldi, Bruno
    Caron, Renato F.
    Bakic, Predrag R.
    Foi, Alessandro
    Maidment, Andrew D. A.
    Vieira, Marcelo A. C.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : 2683 - 2689
  • [29] Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data
    Bouwman, R. W.
    van Engen, R. E.
    Young, K. C.
    den Heeten, G. J.
    Broeders, M. J. M.
    Schopphoven, S.
    Jeukens, C. R. L. P. N.
    Veldkamp, W. J. H.
    Dance, D. R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 7893 - 7907
  • [30] Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study
    Brombal, Luca
    Arfelli, Fulvia
    Delogu, Pasquale
    Donato, Sandro
    Mettivier, Giovanni
    Michielsen, Koen
    Oliva, Piernicola
    Taibi, Angelo
    Sechopoulos, Ioannis
    Longo, Renata
    Fedon, Christian