Left Atrial Appendage Analysis from Echocardiographic Images: Relevance in Left Atrial Appendage Occlusion

被引:0
作者
Sarapardeh, Haniyeh Samareh Hemmati [1 ]
Fayazi, Ali [1 ]
Zadeh, Hossein Ghayoumi [1 ]
Rezaee, Khosro [2 ]
机构
[1] Vali E Asr Univ Rafsanjan, Dept Elect Engn, 22 Bahman Sq, Rafsanjan 7718897111, Iran
[2] Meybod Univ, Dept Biomed Engn, Meybod 8961699557, Iran
关键词
left atrial appendage; neural network; Watchman; echocardiography; segmentation; SEGMENTATION; FIBRILLATION; FUSION;
D O I
10.1520/JTE20230425
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Atrial fibrillation, a prevalent cardiac arrhythmia, disrupts the normal path of electrical signals within the heart. To address this issue, the left atrial appendage closure is often considered. This involves using a closure instrument named the Watchman to obstruct the left atrial appendage (LAA) ostium. The wide variety of LAA shapes, sizes, and forms in individuals makes selecting the correct Watchman size crucial. This study first isolates the LAA from echocardiographic images and then recommends the appropriate Watchman size. The 3-D echocardiographic images used in this study are from 32 male and female patients who underwent successful LAA closure at Kings College Hospital London over two years. For each patient, there are 208 cardiac echo slices in the imaging mode. This study presents an image processing -based model to separate LAA regions and extract relevant features. These features are then inputted into a classification platform in which a neural network determines the suitable Watchman size. The average and mode Hausdorff distances, calculated between the proposed method and the traditional manual calculation for the 501 analyzed LAA images, are approximately 0.2467 and 0.0587, respectively. Because of limited data, a 10 -fold cross -validation was used to assess the classifier, yielding an accuracy of 74.07 %. The proposed model effectively isolated the LAA from the corresponding slices of the 3-D echocardiographic images. However, the classifier's accuracy is not ideal because of insufficient data, which could be improved by expanding the database. This research's outcomes could aid physicians in selecting the proper Watchman size.
引用
收藏
页码:2175 / 2192
页数:18
相关论文
共 30 条
[1]   A Hybrid Algorithm to Enhance Colour Retinal Fundus Images Using a Wiener Filter and CLAHE [J].
Alwazzan, Mohammed J. ;
Ismael, Mohammed A. ;
Ahmed, Asmaa N. .
JOURNAL OF DIGITAL IMAGING, 2021, 34 (03) :750-759
[2]  
Banaeyan M., 2021, 2021 5 INT C PATTERN, P1, DOI [10.1109/IPRIA53572.2021.9483533, DOI 10.1109/IPRIA53572.2021.9483533]
[3]   Left Atrial Appendage Segmentation Using Fully Convolutional Neural Networks and Modified Three-Dimensional Conditional Random Fields [J].
Jin, Cheng ;
Feng, Jianjiang ;
Wang, Lei ;
Yu, Heng ;
Liu, Jiang ;
Lu, Jiwen ;
Zhou, Jie .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (06) :1906-1916
[4]  
Daoudi Abdelaziz, 2014, Statistical Atlases and Computational Models of the Heart. Imaging and Modelling Challenges. 4th International Workshop, STACOM 2013, Held in Conjunction with MICCAI 2013. Revised Selected Papers: LNCS 8330, P14, DOI 10.1007/978-3-642-54268-8_2
[5]   Inflow Typology and Ventricular Geometry Determine Efficiency of Filling in the Hypoplastic Left Heart [J].
de Vecchi, Adelaide ;
Nordsletten, David A. ;
Remme, Espen W. ;
Bellsham-Revell, Hannah ;
Greil, Gerald ;
Simpson, John M. ;
Razavi, Reza ;
Smith, Nicolas P. .
ANNALS OF THORACIC SURGERY, 2012, 94 (05) :1562-1569
[6]   Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation [J].
Duarte, Rui ;
Stainthorpe, Angela ;
Mahon, James ;
Greenhalgh, Janette ;
Richardson, Marty ;
Nevitt, Sarah ;
Kotas, Eleanor ;
Boland, Angela ;
Thom, Howard ;
Marshall, Tom ;
Hall, Mark ;
Takwoingi, Yemisi .
PLOS ONE, 2019, 14 (12)
[7]   Atrial fibrillation and stroke: A review and new insights [J].
Escudero-Martinez, Irene ;
Morales-Caba, Lluis ;
Segura, Tomas .
TRENDS IN CARDIOVASCULAR MEDICINE, 2023, 33 (01) :23-29
[8]  
Ghayoumi Zadeh H., 2021, Iranian Journal of Medical Physics, V18, P123, DOI [10.22038/ijmp.2020.43736.1663, DOI 10.22038/IJMP.2020.43736.1663]
[9]   EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion - an update [J].
Glikson, Michael ;
Wolff, Rafael ;
Hindricks, Gerhard ;
Mandrola, John ;
Camm, A. John ;
Lip, Gregory Y. H. ;
Fauchier, Laurent ;
Betts, Tim R. ;
Lewalter, Thorsten ;
Saw, Jacqueline ;
Tzikas, Apostolos ;
Sternik, Leonid ;
Nietlispach, Fabian ;
Berti, Sergio ;
Sievert, Horst ;
Bertog, Stefan ;
Meier, Bernhard .
EUROPACE, 2020, 22 (02) :184
[10]   Automated left atrial time-resolved segmentation in MRI long-axis cine images using active contours [J].
Gonzales, Ricardo A. ;
Seemann, Felicia ;
Lamy, Jerome ;
Arvidsson, Per M. ;
Heiberg, Einar ;
Murray, Victor ;
Peters, Dana C. .
BMC MEDICAL IMAGING, 2021, 21 (01)