Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac

被引:12
作者
Nguyen, Daniel [1 ]
Reinoso, Rebeca [1 ]
Farah, Jad [2 ]
Yossi, Sena [1 ]
Lorchel, Fabrice [1 ]
Passerat, Victor [1 ]
Louet, Estelle [1 ]
Pouchard, Isabelle [1 ]
Khodri, Mustapha [1 ]
Barbet, Nicolas [1 ]
机构
[1] ORLAMs Grp, Dept Radiat Oncol, Lyon, France
[2] Vis RT Ltd, Dove House,Arcadia Ave, London N3 2JU, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 26卷
关键词
Deep-inspiration breath-hold; Lung stereotactic body radiotherapy; Ring-mounted SGRT system; Intra-fraction control; TUMOR MOTION; SYSTEM; EXPERIENCE; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.phro.2023.100448
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a +/- 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1 degrees (range: 0.6 degrees-1.1 degrees) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Clinical Evaluation of X-Ray Voxel Monte Carlo Versus Pencil Beam-Based Dose Calculation in Stereotactic Body Radiotherapy of Lung Cancer Under Normal and Deep Inspiration Breath Hold
    Landoni, V.
    Borzi, G. R.
    Strolin, S.
    Bruzzaniti, V.
    Soriani, A.
    D'Alessio, D.
    Ambesi, F.
    Di Grazia, A. M.
    Strigari, L.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (03) : 334 - 342
  • [42] Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer
    Han-Oh, Sarah
    Hill, Colin
    Wang, Ken Kang-Hsin
    Ding, Kai
    Wright, Jean L.
    Alcorn, Sara
    Meyer, Jeffrey
    Herman, Joseph
    Narang, Amol
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (02)
  • [43] Protocol of a phase II study to evaluate the efficacy and safety of deep-inspiration breath-hold daily online adaptive radiotherapy for centrally located lung tumours (PUDDING study)
    Noriko Kishi
    Masahiro Yoneyama
    Hiroyuki Inoo
    Minoru Inoue
    Hiraku Iramina
    Akiyoshi Nakakura
    Tomohiro Ono
    Hideaki Hirashima
    Takanori Adachi
    Norimasa Matsushita
    Makoto Sasaki
    Takahiro Fujimoto
    Mitsuhiro Nakamura
    Yukinori Matsuo
    Takashi Mizowaki
    Radiation Oncology, 19
  • [44] A uniform and versatile surface-guided radiotherapy procedure and workflow for high-quality breast deep-inspiration breath-hold treatment in a multi-center institution
    Li, Guang
    Lu, Wei
    O'Grady, Kyle
    Yan, Iris
    Yorke, Ellen
    Arriba, Laura I. Cervino
    Powell, Simon
    Hong, Linda
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [45] Deep inspiration breath hold real-time tumor-tracking radiation therapy (DBRT) as a novel stereotactic body radiation therapy approach for lung tumors
    Tanaka, Hidekazu
    Ono, Taiki
    Ueda, Kazushi
    Karita, Masako
    Manabe, Yuki
    Kajima, Miki
    Sera, Tatsuhiro
    Fujimoto, Koya
    Yuasa, Yuki
    Shiinoki, Takehiro
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [46] Postoperative radiotherapy for right breast cancer with regional nodal irradiation utilizing the surface-guided radiotherapy based deep inspiration breath hold technique on a TrueBeam HD linear accelerator: A case report
    Li, Chao
    Wu, Dang
    Guo, Siyu
    Zhang, Bicheng
    Wei, Qichun
    Zhang, Ting
    MEDICAL DOSIMETRY, 2025, 50 (01) : 13 - 18
  • [47] Application and limitation of radiomics approach to prognostic prediction for lung stereotactic body radiotherapy using breath-hold CT images with random survival forest: A multi-institutional study
    Kakino, Ryo
    Nakamura, Mitsuhiro
    Mitsuyoshi, Takamasa
    Shintani, Takashi
    Kokubo, Masaki
    Negoro, Yoshiharu
    Fushiki, Masato
    Ogura, Masakazu
    Itasaka, Satoshi
    Yamauchi, Chikako
    Otsu, Shuji
    Sakamoto, Takashi
    Sakamoto, Masato
    Araki, Norio
    Hirashima, Hideaki
    Adachi, Takanori
    Matsuo, Yukinori
    Mizowaki, Takashi
    MEDICAL PHYSICS, 2020, 47 (09) : 4634 - 4643
  • [48] Comparison of cone beam computed tomography (CBCT)-based image guided radiotherapy approaches in the reduction of setup uncertainties during deep inspiration breath-hold radiotherapy (DIBH-RT) for left breast cancer
    Abubakar, Auwal
    Shaukat, Shazril Imran
    Karim, Noor Khairiah A.
    Kassim, Mohammed Zakir
    Appalanaido, Gokula Kumar
    Zin, Hafiz Mohd
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [49] Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
    Miura, Hideharu
    Ozawa, Shuichi
    Doi, Yoshiko
    Nakao, Minoru
    Kubo, Katsumaro
    Kenjo, Masahiko
    Nagata, Yasushi
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (04) : 575 - 585
  • [50] Novel Use of Continuous Positive Airway Pressure Permits Heart- and Lung-Sparing Mediastinal Involved-Site Radiation Therapy for Patient With Hodgkin Lymphoma in Community Clinic When Deep Inspiration Breath-Hold Technique Is Not Available
    Kil, Whoon Jong
    PRACTICAL RADIATION ONCOLOGY, 2019, 9 (03) : 142 - 146