Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac

被引:12
作者
Nguyen, Daniel [1 ]
Reinoso, Rebeca [1 ]
Farah, Jad [2 ]
Yossi, Sena [1 ]
Lorchel, Fabrice [1 ]
Passerat, Victor [1 ]
Louet, Estelle [1 ]
Pouchard, Isabelle [1 ]
Khodri, Mustapha [1 ]
Barbet, Nicolas [1 ]
机构
[1] ORLAMs Grp, Dept Radiat Oncol, Lyon, France
[2] Vis RT Ltd, Dove House,Arcadia Ave, London N3 2JU, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 26卷
关键词
Deep-inspiration breath-hold; Lung stereotactic body radiotherapy; Ring-mounted SGRT system; Intra-fraction control; TUMOR MOTION; SYSTEM; EXPERIENCE; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.phro.2023.100448
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a +/- 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1 degrees (range: 0.6 degrees-1.1 degrees) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Evaluation of active breathing control-moderate deep inspiration breath-hold in definitive non-small cell lung cancer radiotherapy
    Sager, O.
    Beyzadeoglu, M.
    Dincoglan, F.
    Oysul, K.
    Kahya, Y. Elcim
    Gamsiz, H.
    Uysal, B.
    Demiral, S.
    Dirican, B.
    Surenkok, S.
    NEOPLASMA, 2012, 59 (03) : 333 - 340
  • [32] Real-time monitoring and control on deep inspiration breath-hold for lung cancer radiotherapy-Combination of ABC and external marker tracking
    Wong, Victy Y. W.
    Tung, Stewart Y.
    Ng, Alice W. Y.
    Li, Francis A. S.
    Leung, Joyce O. Y.
    MEDICAL PHYSICS, 2010, 37 (09) : 4673 - 4683
  • [33] Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapy
    Cervino, Laura I.
    Gupta, Sonia
    Rose, Mary A.
    Yashar, Catheryn
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22) : 6853 - 6865
  • [34] Protocol of a phase II study to evaluate the efficacy and safety of deep-inspiration breath-hold daily online adaptive radiotherapy for centrally located lung tumours (PUDDING study)
    Kishi, Noriko
    Yoneyama, Masahiro
    Inoo, Hiroyuki
    Inoue, Minoru
    Iramina, Hiraku
    Nakakura, Akiyoshi
    Ono, Tomohiro
    Hirashima, Hideaki
    Adachi, Takanori
    Matsushita, Norimasa
    Sasaki, Makoto
    Fujimoto, Takahiro
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Mizowaki, Takashi
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [35] Deep-learning based surface region selection for deep inspiration breath hold (DIBH) monitoring in left breast cancer radiotherapy
    Chen, Haibin
    Chen, Mingli
    Lu, Weiguo
    Zhao, Bo
    Jiang, Steve
    Zhou, Linghong
    Kim, Nathan
    Spangler, Ann
    Rahimi, Asal
    Zhen, Xin
    Gu, Xuejun
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (24)
  • [36] Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience
    Penninkhof, Joan
    Fremeijer, Kimm
    Harten, Kirsten Offereins-van
    van Wanrooij, Cynthia
    Quint, Sandra
    Kunnen, Britt
    Hoffmans-Holtzer, Nienke
    Swaak, Annemarie
    Baaijens, Margreet
    Dirkx, Maarten
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 21 : 51 - 57
  • [37] Single-institution report of setup margins of voluntary deep-inspiration breath-hold (DIBH) whole breast radiotherapy implemented with real-time surface imaging
    Xiao, Annie
    Crosby, Jennie
    Malin, Martha
    Kang, Hyejoo
    Washington, Maxine
    Hasan, Yasmin
    Chmura, Steven J.
    Al-Hallaq, Hania A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 205 - 213
  • [38] Dosimetric analysis of tangent-based volumetric modulated arc therapy with deep inspiration breath-hold technique for left breast cancer patients
    Yu, Pei-Chieh
    Wu, Ching-Jung
    Tsai, Yu-Lun
    Shaw, Suzun
    Sung, Shih-Yu
    Lui, Louis Tak
    Nien, Hsin-Hua
    RADIATION ONCOLOGY, 2018, 13
  • [39] Surface guidance compared with ultrasound-based monitoring and diaphragm position in cone-beam computed tomography during abdominal stereotactic radiotherapy in breath-hold
    Kaestner, Lena
    Streb, Lara
    Hetjens, Svetlana
    Buergy, Daniel
    Sihono, Dwi S. K.
    Fleckenstein, Jens
    Kalisch, Iris
    Eckl, Miriam
    Giordano, Frank A.
    Lohr, Frank
    Stieler, Florian
    Boda-Heggemann, Judit
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [40] Dosimetric analysis of tangent-based volumetric modulated arc therapy with deep inspiration breath-hold technique for left breast cancer patients
    Pei-Chieh Yu
    Ching-Jung Wu
    Yu-Lun Tsai
    Suzun Shaw
    Shih-Yu Sung
    Louis Tak Lui
    Hsin-Hua Nien
    Radiation Oncology, 13