Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac

被引:12
|
作者
Nguyen, Daniel [1 ]
Reinoso, Rebeca [1 ]
Farah, Jad [2 ]
Yossi, Sena [1 ]
Lorchel, Fabrice [1 ]
Passerat, Victor [1 ]
Louet, Estelle [1 ]
Pouchard, Isabelle [1 ]
Khodri, Mustapha [1 ]
Barbet, Nicolas [1 ]
机构
[1] ORLAMs Grp, Dept Radiat Oncol, Lyon, France
[2] Vis RT Ltd, Dove House,Arcadia Ave, London N3 2JU, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 26卷
关键词
Deep-inspiration breath-hold; Lung stereotactic body radiotherapy; Ring-mounted SGRT system; Intra-fraction control; TUMOR MOTION; SYSTEM; EXPERIENCE; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.phro.2023.100448
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a +/- 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1 degrees (range: 0.6 degrees-1.1 degrees) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Clinical implementation and evaluation of stereotactic liver radiotherapy in inspiration breath-hold using nasal high-flow therapy and surface guidance
    Hazelaar, Colien
    Canters, Richard
    Kremer, Kirsten
    Lubken, Indra
    Vaassen, Femke
    Buijsen, Jeroen
    Berbee, Maaike
    van Elmpt, Wouter
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1164) : 1950 - 1958
  • [22] Artificial Intelligence-Based Patient Selection for Deep Inspiration Breath-Hold Breast Radiotherapy from Respiratory Signals
    Vendrame, Alessandra
    Cappelletto, Cristina
    Chiovati, Paola
    Vinante, Lorenzo
    Parvej, Masud
    Caroli, Angela
    Pirrone, Giovanni
    Barresi, Loredana
    Drigo, Annalisa
    Avanzo, Michele
    APPLIED SCIENCES-BASEL, 2023, 13 (08):
  • [23] Target position reproducibility in left-breast irradiation with deep inspiration breath-hold using multiple optical surface control points
    Fassi, Aurora
    Ivaldi, Giovanni B.
    de Fatis, Paola Tabarelli
    Liotta, Marco
    Meaglia, Ilaria
    Porcu, Patrizia
    Regolo, Lea
    Riboldi, Marco
    Baroni, Guido
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 35 - 43
  • [24] Deep inspiratory breath hold assisted by continuous positive airway pressure ventilation for lung stereotactic body radiotherapy
    Appel, S.
    Lawrence, Y. R.
    Bar, J.
    Jacobson, G.
    Marom, E. M.
    Katzman, T.
    Ben-Ayun, M.
    Dubinski, S.
    Haisraely, O.
    Weizman, N.
    Davidson, T.
    Weiss, I.
    Mansano, A.
    Goldstein, J. D.
    Symon, Z.
    CANCER RADIOTHERAPIE, 2023, 27 (01): : 23 - 30
  • [25] Preoperative spirometry and BMI in deep inspiration breath-hold radiotherapy: the early detection of cardiac and lung dose predictors without radiation exposure
    Yutaro Koide
    Hidetoshi Shimizu
    Takahiro Aoyama
    Tomoki Kitagawa
    Risei Miyauchi
    Yui Watanabe
    Hiroyuki Tachibana
    Takeshi Kodaira
    Radiation Oncology, 17
  • [26] Preoperative spirometry and BMI in deep inspiration breath-hold radiotherapy: the early detection of cardiac and lung dose predictors without radiation exposure
    Koide, Yutaro
    Shimizu, Hidetoshi
    Aoyama, Takahiro
    Kitagawa, Tomoki
    Miyauchi, Risei
    Watanabe, Yui
    Tachibana, Hiroyuki
    Kodaira, Takeshi
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [27] Setup margins based on the inter- and intrafractional setup error of left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT)
    Rudat, Volker
    Shi, Yanyan
    Zhao, Ruping
    Yu, Wei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [28] The impact of modern radiotherapy on long-term cardiac sequelae in breast cancer survivor: a focus on deep inspiration breath-hold (DIBH) technique
    Salvestrini, V
    Iorio, G. C.
    Borghetti, P.
    De Felice, F.
    Greco, C.
    Nardone, V
    Fiorentino, A.
    Gregucci, F.
    Desideri, I
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2022, 148 (02) : 409 - 417
  • [29] The reproducibility of deep-inspiration breath-hold 18F-FDG PET/CT technique in diagnosing various cancers affected by respiratory motion
    Shigeki Nagamachi
    Hideyuki Wakamatsu
    Shogo Kiyohara
    Seigo Fujita
    Shigemi Futami
    Hideo Arita
    Shozo Tamura
    Keiichi Kawai
    Annals of Nuclear Medicine, 2010, 24 : 171 - 178
  • [30] Evaluation of active breathing control-moderate deep inspiration breath-hold in definitive non-small cell lung cancer radiotherapy
    Sager, O.
    Beyzadeoglu, M.
    Dincoglan, F.
    Oysul, K.
    Kahya, Y. Elcim
    Gamsiz, H.
    Uysal, B.
    Demiral, S.
    Dirican, B.
    Surenkok, S.
    NEOPLASMA, 2012, 59 (03) : 333 - 340