Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac

被引:12
|
作者
Nguyen, Daniel [1 ]
Reinoso, Rebeca [1 ]
Farah, Jad [2 ]
Yossi, Sena [1 ]
Lorchel, Fabrice [1 ]
Passerat, Victor [1 ]
Louet, Estelle [1 ]
Pouchard, Isabelle [1 ]
Khodri, Mustapha [1 ]
Barbet, Nicolas [1 ]
机构
[1] ORLAMs Grp, Dept Radiat Oncol, Lyon, France
[2] Vis RT Ltd, Dove House,Arcadia Ave, London N3 2JU, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 26卷
关键词
Deep-inspiration breath-hold; Lung stereotactic body radiotherapy; Ring-mounted SGRT system; Intra-fraction control; TUMOR MOTION; SYSTEM; EXPERIENCE; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.phro.2023.100448
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a +/- 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1 degrees (range: 0.6 degrees-1.1 degrees) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Application and dosimetric comparison of surface-guided deep inspiration breath-hold for lung stereotactic body radiotherapy
    Wang, Jiaxin
    Dong, Tingting
    Meng, Xiangyin
    Li, Wenbo
    Li, Nan
    Wang, Yijun
    Yang, Bo
    Qiu, Jie
    MEDICAL DOSIMETRY, 2024, 49 (04) : 372 - 379
  • [2] Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold
    Naumann, Patrick
    Batista, Vania
    Farnia, Benjamin
    Fischer, Jann
    Liermann, Jakob
    Tonndorf-Martini, Eric
    Rhein, Bernhard
    Debus, Juergen
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [3] Evaluating intra-fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath-hold
    Fu, Weihua
    Zhang, Yongqian
    Mehta, Kiran
    Chen, Alex
    Musunuru, Hima Bindu
    Pucci, Pietro
    Kubis, Jason
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [4] Tailored stereotactic radiotherapy technique using deep inspiration breath-hold to reduce stomach dose for cardiac radioablation
    Cha, Myung-Jin
    Cuculich, Phillip S.
    Robinson, Clifford G.
    Chang, Ji Hyun
    RADIATION ONCOLOGY JOURNAL, 2021, 39 (03): : 167 - 173
  • [5] Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy
    Turna, Menekse
    Kucukmorkoc, Esra
    Rzazade, Rashad
    Canoglu, Mehmet Dogu
    Kucuk, Nadir
    Caglar, Hale Basak
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2023, 28
  • [6] Deep inspiration breath-hold technique guided by an opto-electronic system for extracranial stereotactic treatments
    Garibaldi, Cristina
    Catalano, Gianpiero
    Baroni, Guido
    Tagaste, Barbara
    Riboldi, Marco
    Spadea, Maria Francesca
    Ciocca, Mario
    Cambria, Raffaella
    Serafini, Flavia
    Orecchia, Roberto
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 14 - 25
  • [7] Intrafractional fiducial marker position variations in stereotactic liver radiotherapy during voluntary deep inspiration breath-hold
    Stick, Line Bjerregaard
    Vogelius, Ivan Richter
    Risum, Signe
    Josipovic, Mirjana
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1116)
  • [8] Fast 3D Imaging via Deep learning for Deep Inspiration Breath-hold Lung Radiotherapy
    Lei, Yang
    Tian, Zhen
    Wang, Tonghe
    Axente, Marian
    Roper, Justin
    Higgins, Kristin
    Bradley, Jeffrey D.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [9] A Prospective Study on the Use of Deep Inspiration Breath-Hold Technique in External Beam Radiotherapy for Breast Cancer
    Jose, Nijo
    Jayashree, N. P.
    Lewis, Shirley
    Sharan, Krishna
    Velu, Umesh
    Reddy, Anusha
    Singh, Anshul
    Rao, Shreekripa
    Shambhavi, C.
    Nisha, Rachel
    Nair, Sarath
    Nagesh, Jyothi
    Chandraguthi, Srinidhi
    SOUTH ASIAN JOURNAL OF CANCER, 2024,
  • [10] The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer
    Rosenzweig, KE
    Hanley, J
    Mah, D
    Mageras, G
    Hunt, M
    Toner, S
    Burman, C
    Ling, CC
    Mychalczak, B
    Fuks, Z
    Leibel, SA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01): : 81 - 87