Considerable inter-individual variability of tibial geometric ratios renders bone-implant mismatch unavoidable using off-the-shelf total knee arthroplasty: a systematic review and meta-analysis

被引:20
作者
Beckers, Lucas [1 ]
Muller, Jacobus H. [2 ]
Daxhelet, Jeremy [1 ]
Ratano, Salvatore [1 ]
Saffarini, Mo [2 ]
Ait-Si-Selmi, Tarik [1 ]
Bonnin, Michel P. [1 ]
机构
[1] Hop Prive Jean Mermoz, Ramsay Sante, Ctr Orthoped Santy, Lyon, France
[2] ReSurg SA, Rue St Jean 22, CH-1260 Nyon, Switzerland
关键词
Knee; Tibia; Total knee arthroplasty; Total knee replacement; Off-the-shelf; Morphology; Morphometry; Geometry; ANTHROPOMETRIC MEASUREMENTS; PROXIMAL TIBIA; ROTATIONAL ALIGNMENT; GENDER-DIFFERENCES; MORPHOLOGY; COMPONENT; DESIGN; MORPHOMETRY; RESECTION; PLATEAU;
D O I
10.1007/s00167-021-06623-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this systematic review and meta-analysis was to investigate the variability in tibial geometric ratios among knees of different sexes and races to determine whether commercially-available tibial baseplates accommodate the morphologic diversity. The hypothesis was that anthropometric studies report considerable variability of tibial geometric ratios among sexes and races. Methods This systematic review and meta-analysis was performed according to the preferred reporting items for systematic reviews and meta-analyses (PRISMA) criteria. Two authors independently conducted an electronic search using MEDLINE(R) and Embase(R) on 28 January 2021 for clinical studies reporting on tibial geometric ratios. Tibial geometric ratios, as reported by the clinical studies, were represented by plotting their means and two standard deviations for comparison to two symmetric and two asymmetric commercially-available tibial baseplates. Results A total of 27 articles that reported on a combined total of 20,944 knees were eligible for data extraction. Variation in tibial aspect ratios was equal among sexes. The greatest variation in aspect ratio was observed among East Asians, followed by Caucasians, African-Americans, Indian and Middle Easterns. The variation in tibial asymmetry ratio was larger among men compared to women. The greatest variation in asymmetry ratio was observed among African-Americans, followed by Caucasians, East Asians, Indian and Middle Easterns. Bone-implant mismatch of > 3 mm overhang or > 4 mm under-coverage with four commercially-available tibial baseplates occurred in large proportions of knees due to variations in aspect ratio (in 17-100% of knees) and asymmetry ratio (in 7-100% of knees). Conclusion Anthropometric studies reported considerable inter-individual variability of tibial geometric ratios, which exceeded effects of sexual dimorphism and racial diversity. Bone-implant mismatch may be unavoidable in a large proportion of knees, when considering that a surgeon generally only uses one or a few TKA brands. These findings support the drive towards patient-specific implants to potentially achieve accurate bone-implant fit by implant customisation.
引用
收藏
页码:1284 / 1298
页数:15
相关论文
共 54 条
[41]  
Reddy A V Gurava, 2020, J Clin Orthop Trauma, V11, pS228, DOI 10.1016/j.jcot.2019.04.015
[42]   The original Akagi line is the most reliable: a systematic review of landmarks for rotational alignment of the tibial component in TKA [J].
Saffarini, Mo ;
Nover, Luca ;
Tandogan, Reha ;
Becker, Roland ;
Moser, Lukas B. ;
Hirschmann, Michael T. ;
Indelli, Pier F. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) :1018-1027
[43]  
Shah D., 2013, Open J Rheumatol Autoimmune Dis, V3, P263, DOI [10.4236/ojra.2013.34041, DOI 10.4236/OJRA.2013.34041]
[44]   Intraoperative physiological lateral laxity in extension and flexion for varus knees did not affect short-term clinical outcomes and patient satisfaction [J].
Tanaka, Yoshihisa ;
Nakamura, Shinichiro ;
Kuriyama, Shinichi ;
Nishitani, Kohei ;
Ito, Hiromu ;
Lyman, Stephen ;
Matsuda, Shuichi .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (12) :3888-3898
[45]   Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis [J].
Tandogan, Reha N. ;
Kort, Nanne P. ;
Ercin, Ersin ;
van Rooij, Floris ;
Nover, Luca ;
Saffarini, Mo ;
Hirschmann, Michael T. ;
Becker, Roland ;
Dejour, David .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (08) :2654-2665
[46]  
Westrich G H, 1995, J Arthroplasty, V10, P47
[47]   IMPROVED FIT BY ASYMMETRIC TIBIAL PROSTHESIS FOR TOTAL KNEE ARTHROPLASTY [J].
WEVERS, HW ;
SIMURDA, M ;
GRIFFIN, M ;
TARREL, J .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (04) :297-300
[48]   Intraoperative anthropometric measurements of tibial morphology: comparisons with the dimensions of current tibial implants [J].
Yang, Bo ;
Song, Chang-hui ;
Yu, Jia-kuo ;
Yang, Yong-qiang ;
Gong, Xi ;
Chen, Lian-xu ;
Wang, Yong-jian ;
Wang, Jian .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) :2924-2930
[49]   Intraoperative study on anthropometry and gender differences of the proximal tibial plateau at the arthroplasty resection surface [J].
Yang Bo ;
Yu Jiakuo ;
Gong Xi ;
Chen Lianxu ;
Wang Yongjian ;
Wang Jian ;
Wang Haijun ;
Zhang Jiying .
CHINESE MEDICAL JOURNAL, 2014, 127 (01) :92-95
[50]   Computed Tomography Morphometric Study of Gender Differences in Osteoarthritis Proximal Tibias [J].
Yang, Bo ;
Yu, Jia-Kuo ;
Zheng, Zhuo-Zhao ;
Lu, Zhi-Hua ;
Zhang, Ji-Ying ;
Cheng, Ji-Hong .
JOURNAL OF ARTHROPLASTY, 2013, 28 (07) :1117-1120