Robust parameter design of the procedure for determining the chemical composition of copper alloys by X-ray fluorescence

被引:0
|
作者
Mitrofanova, S. A. [1 ,2 ]
Muravyeva, I. V. [3 ]
机构
[1] Sci Res Inst Transport & Construct Complex, Moscow, Russia
[2] Acad Standardizat Metrol & Certificat Educ, Moscow, Russia
[3] Natl Univ Sci & Technol MISiS, Moscow, Russia
关键词
Measurement procedure; X-ray fluorescence method; Spectrometer; Chemical composition; Copper alloys; Robust design of experiment; Measurement error; 90.27.31;
D O I
10.1007/s11018-024-02304-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper offers a brief overview of the modern procedures for determining the chemical composition of copper alloys along with the applied methods of analytical control. It has been shown that to obtain reliable and comparable results of measuring the mass fractions of copper alloys elements within wide ranges of values, the most suitable procedures are based on the X-ray fluorescence method, implemented using portable X-ray fluorescence spectrometers. In order to select the optimal values of the influencing quantities when determining the chemical composition of copper alloys, a robust parameter design of a quantitative chemical analysis procedure was carried out using X-50 Mobile X-ray fluorescence spectrometer. The use of robust parameter design as opposed to conducting a full factorial experiment when developing a measurement procedure makes it possible to optimize the measurement conditions and obtain results of the required accuracy with a limited number of experiments and a maximum number of controlled factors. An example of drawing up an experimental plan for the parameter design of such procedure is provided, and a statistical analysis of the measurement results is carried out. The authors have analyzed and selected the optimal measurement conditions (influencing quantities), which ensure the minimum error of the results of measuring the mass fraction of elements. By selecting the optimal values of the influencing quantities based on the results of robust parameter design of the quantitative chemical analysis procedure, it became possible to increase the accuracy of determining the chemical composition of copper alloys and, hence, improve the reliability of the product quality control results at a relatively low cost. Such approach can be recommended for use by analytical laboratories developing procedures of quantitative chemical analysis for metallurgical enterprises.
引用
收藏
页码:889 / 896
页数:8
相关论文
共 50 条
  • [41] SIMPLE X-RAY-FLUORESCENCE METHOD FOR DETERMINING COMPOSITION OF PBXSN1-XTE PSEUDOBINARY ALLOYS
    FANO, V
    GHEZZI, C
    ZANOTTI, L
    APPLIED SPECTROSCOPY, 1976, 30 (03) : 359 - 361
  • [42] X-RAY ANALYSIS OF COPPER BASE ALLOYS AND PURE COPPER RESIDUALS
    DRYER, HT
    SPECTROCHIMICA ACTA, 1960, 16 (05): : 627 - 627
  • [43] Development of a procedure for the determination of X-ray fluorescence of metals in aerosols
    M. V. Stavitskaya
    E. N. Korzhova
    A. N. Smagunova
    Journal of Analytical Chemistry, 2010, 65 : 1245 - 1253
  • [44] Development of a procedure for the determination of X-ray fluorescence of metals in aerosols
    Stavitskaya, M. V.
    Korzhova, E. N.
    Smagunova, A. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (12) : 1245 - 1253
  • [45] Chemical and Structural Analysis of Rocks Using X-ray Fluorescence and X-ray Diffraction Techniques
    Sabri, Mohammed M.
    ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY, 2020, 8 (01): : 79 - 87
  • [46] Chemical composition and heterogeneity of Wild 2 cometary particles determined by synchrotron X-ray fluorescence
    Lanzirotti, A.
    Sutton, S. R.
    Flynn, G. J.
    Newville, A.
    Rao, W.
    METEORITICS & PLANETARY SCIENCE, 2008, 43 (1-2) : 187 - 213
  • [47] Using X-ray fluorescence to assess the chemical composition and resistivity of simulated cementitious pore solutions
    Marisol Tsui Chang
    Prannoy Suraneni
    O. Burkan Isgor
    David Trejo
    W. Jason Weiss
    International Journal of Advances in Engineering Sciences and Applied Mathematics, 2017, 9 (3) : 136 - 143
  • [48] DETERMINATION OF CHANGE IN CHEMICAL COMPOSITION OF A SOLID DURING X-RAY SPECTRAL FLUORESCENCE ANALYSIS OF PULP
    STULOV, BA
    INDUSTRIAL LABORATORY, 1970, 36 (08): : 1184 - &
  • [49] Possibilities and Limitations of Various X-ray Fluorescence Techniques in Studying the Chemical Composition of Ancient Ceramics
    V. M. Chubarov
    G. V. Pashkova
    A. S. Maltsev
    M. M. Mukhamedova
    M. A. Statkus
    A. G. Revenko
    Journal of Analytical Chemistry, 2024, 79 : 262 - 272
  • [50] Possibilities and Limitations of Various X-ray Fluorescence Techniques in Studying the Chemical Composition of Ancient Ceramics
    Chubarov, V. M.
    Pashkova, G. V.
    Maltsev, A. S.
    Mukhamedova, M. M.
    Statkus, M. A.
    Revenko, A. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (03) : 262 - 272