The accuracy of artificial intelligence deformed nodal structures in cervical online cone-beam-based adaptive radiotherapy

被引:0
作者
Wang, Ethan [1 ]
Yen, Allen [1 ]
Hrycushko, Brian [1 ]
Wang, Siqiu [1 ]
Lin, Jingyin [1 ]
Zhong, Xinran [1 ]
Dohopolski, Michael [1 ]
Nwachukwu, Chika [1 ]
Iqbal, Zohaib [1 ]
Albuquerque, Kevin [1 ,2 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX USA
[2] 2280 Inwood Rd, Dallas, TX 75235 USA
关键词
Adaptive Radiotherapy; Cone -beam CT; Artificial Intelligence; Deformable Image Registration; COMPUTED-TOMOGRAPHY; IMAGE REGISTRATION; RADIATION-THERAPY; LYMPH-NODES; PROPAGATION; PATTERNS; IMPACT;
D O I
10.1016/j.phro.2024.100546
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Online cone-beam-based adaptive radiotherapy (ART) adjusts for anatomical changes during external beam radiotherapy. However, limited cone-beam image quality complicates nodal contouring. Despite this challenge, artificial-intelligence guided deformation (AID) can auto-generate nodal contours. Our study investigated the optimal use of such contours in cervical online cone-beam-based ART. Materials and Methods: From 136 adaptive fractions across 21 cervical cancer patients with nodal disease, we extracted 649 clinically-delivered and AID clinical target volume (CTV) lymph node boost structures. We assessed geometric alignment between AID and clinical CTVs via dice similarity coefficient, and 95% Hausdorff distance, and geometric coverage of clinical CTVs by AID planning target volumes by false positive dice. Coverage of clinical CTVs by AID contour-based plans was evaluated using D100, D95, V100%, and V95%. Results: Between AID and clinical CTVs, the median dice similarity coefficient was 0.66 and the median 95 % Hausdorff distance was 4.0 mm. The median false positive dice of clinical CTV coverage by AID planning target volumes was 0. The median D100 was 1.00, the median D95 was 1.01, the median V100% was 1.00, and the median V95% was 1.00. Increased nodal volume, fraction number, and daily adaptation were associated with reduced clinical CTV coverage by AID-based plans. Conclusion: In one of the first reports on pelvic nodal ART, AID-based plans could adequately cover nodal targets. However, physician review is required due to performance variation. Greater attention is needed for larger, daily-adapted nodes further into treatment.
引用
收藏
页数:6
相关论文
共 42 条
[1]  
[Anonymous], 2022, Surface distance metrics
[2]  
[Anonymous], 2023, The Jupyter Notebook
[3]  
Archambault Y, 2020, Med Phys Int J, V8, P77
[4]  
ASTRO, 2020, ASTRO Guideline on Radiation Therapy for Cervical Cancer
[5]   Online adaptive radiotherapy of anal cancer: Normal tissue sparing, target propagation methods, and first clinical experience [J].
astroem, Lina M. ;
Behrens, Claus P. ;
Storm, Katrine Smedegaard ;
Sibolt, Patrik ;
Serup-Hansen, Eva .
RADIOTHERAPY AND ONCOLOGY, 2022, 176 :92-98
[6]   Impact of bowel gas and body outline variations on total accumulated dose with intensity-modulated proton therapy in locally advanced cervical cancer patients [J].
Berger, Thomas ;
Petersen, Jorgen Breede Baltzer ;
Lindegaard, Jacob Christian ;
Fokdal, Lars Ulrik ;
Tanderup, Kari .
ACTA ONCOLOGICA, 2017, 56 (11) :1472-1478
[7]   Dosimetric and feasibility evaluation of a CBCT-based daily adaptive radiotherapy protocol for locally advanced cervical cancer [J].
Branco, Daniela ;
Mayadev, Jyoti ;
Moore, Kevin ;
Ray, Xenia .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01)
[8]   Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task [J].
Brock, Kristy K. ;
Mutic, Sasa ;
McNutt, Todd R. ;
Li, Hua ;
Kessler, Marc L. .
MEDICAL PHYSICS, 2017, 44 (07) :E43-E76
[9]   Varian ethos online adaptive radiotherapy for prostate cancer: Early results of contouring accuracy, treatment plan quality, and treatment time [J].
Byrne, Mikel ;
Archibald-Heeren, Ben ;
Hu, Yunfei ;
Teh, Amy ;
Beserminji, Rhea ;
Cai, Emma ;
Liu, Guilin ;
Yates, Angela ;
Rijken, James ;
Collett, Nick ;
Aland, Trent .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01)
[10]   Topographic distribution of lymph node metastasis in patients with stage IB1 cervical cancer: an analysis of 8314 lymph nodes [J].
Cai, Jing ;
He, Xiaoqi ;
Wang, Hongbo ;
Dong, Weihong ;
Zhang, Yuan ;
Zhao, Jing ;
Willborn, Kay C. ;
Huang, Bangxing ;
Wang, Zehua ;
Jiang, Ping .
RADIATION ONCOLOGY, 2021, 16 (01)