Thermodynamic performance of heat pump with R1234ze(E)/R1336mzz (E) binary refrigerant

被引:14
作者
Hu, Hemin [1 ]
Wang, Tao [1 ]
Jiang, Yuyan [3 ]
Bi, Chao [1 ]
Zhang, Bing [1 ]
Fan, Siyi [2 ]
Li, Jianchao [2 ]
An, Siyuan [2 ]
Bai, Xiusen [2 ]
Guo, Cong [3 ]
机构
[1] Beijing Univ Chem Technol, Coll Mech & Elect Engn, Beijing 100029, Peoples R China
[2] Huaneng Beijing Cogenerat Co Ltd, Beijing 100124, Peoples R China
[3] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
关键词
Heat pump; Binary refrigerant; R1234ze(E); R1336mzz; Thermodynamic performance; Temperature glide; DESIGN-DATA; TEMPERATURE; SYSTEMS; R134A; R718; CO2;
D O I
10.1016/j.applthermaleng.2023.120795
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to solve the temperature mismatch issue of cold and hot fluids in evaporation and condensation processes for heat pump system, binary refrigerant R1234ze(E)/R1336mzz is recommended in the present research due to its large temperature glide. Through theoretical analysis, multiple configurations under conditions of three different temperature heat sources (70/50 degrees C, 60/40 degrees C and 50/30 degrees C) and two different heat targets (steam above 100 degrees C and hot water with 70 degrees C) are constructed adopted Ebsilon code. The optimum mass proportion is obtained as 0.3/0.7 for R1234ze(E)/R1336mzz(E), because of its maximum temperature glide (can reach 21.52 degrees C) and excellent thermal performance (large COP, ECOP and exergy efficiency). COP of steam high temperature heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant and the ratio of transferred heat of 110 degrees C condenser to all output heat (containing 110 degrees C and 100 degrees C steam intercooler and condensers) respectively increase up to 67.25% and 335.16% under some certain conditions, compared with that with pure R1336mzz(E). COP of hot water heat pump with R1234ze(E)(0.3)/R1336mzz(E)(0.7) binary refrigerant are respectively 10.31 and 6.89 under 60/40 degrees C and 50/30 degrees C heat source conditions, which greatly increases compared with that of heat pump with pure R1234ze(E) (6.67 and 5.03) and R1336mzz(E) (6.74 and 4.54). The present research may lay a foundation for binary refrigerant adoption to replace the scheme of multi-stage evaporator or multi-stage condenser, which could reduce the irreversible loss of phase change equipment and improve thermodynamic performance of heat pumps.
引用
收藏
页数:13
相关论文
共 48 条
  • [1] DERIVED THERMODYNAMIC DESIGN-DATA FOR HEAT-PUMP SYSTEMS OPERATING ON R717
    ADEFILA, SS
    DEVOTTA, S
    WATSON, FA
    HOLLAND, FA
    [J]. JOURNAL OF HEAT RECOVERY SYSTEMS, 1983, 3 (01): : 11 - 17
  • [2] Ammonia-based compression heat pumps for simultaneous heating and cooling applications in milk pasteurization processes: Performance evaluation
    Ayou, Dereje S.
    Hargiyanto, Reza
    Coronas, Alberto
    [J]. APPLIED THERMAL ENGINEERING, 2022, 217
  • [3] Efficient control of cascade heat pumps using variable speed compressors
    Boahen, Samuel
    Choi, Jong Min
    Amoabeng, Kofi Owura
    Opoku, Richard
    Obeng, George Yaw
    [J]. SCIENTIFIC AFRICAN, 2022, 18
  • [4] Advances in coupled use of renewable energy sources for performance enhancement of vapour compression heat pump: A systematic review of applications to buildings
    Cao, Jingyu
    Zheng, Ling
    Peng, Jinqing
    Wang, Wenjie
    Leung, Michael K. H.
    Zheng, Zhanying
    Hu, Mingke
    Wang, Qiliang
    Cai, Jingyong
    Pei, Gang
    Ji, Jie
    [J]. APPLIED ENERGY, 2023, 332
  • [5] Energy, exergy, economic and environmental analyses and optimization of a novel vapor injection autocascade heat pump for high-temperature water heating
    Chen, Jiaheng
    Chen, Qi
    Qin, Xiang
    Wang, Dingbiao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [6] Carbon neutrality: Toward a sustainable future
    Chen, Jing M.
    [J]. INNOVATION, 2021, 2 (03):
  • [7] Life cycle performance evaluation of cascade-heating high temperature heat pump system for waste heat utilization: Energy consumption, emissions and financial analyses
    Dai, Baomin
    Liu, Xiao
    Liu, Shengchun
    Wang, Dabiao
    Meng, Chenyang
    Wang, Qi
    Song, Yifan
    Zou, Tonghua
    [J]. ENERGY, 2022, 261
  • [8] Experimental study of R744 heat pump system for electric vehicle application
    Dong Junqi
    Wang Yibiao
    Jia Shiwei
    Zhang Xianhui
    Huang Linjie
    [J]. APPLIED THERMAL ENGINEERING, 2021, 183
  • [9] Investigation of cascade high temperature heat pump optimal design theory based on experiment supporting multi-objective optimization
    Dong, Shengming
    Meng, Xiangcai
    Hu, Xiaowei
    Sun, Zhili
    Wang, Huoda
    Luo, Yao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [10] Performance analysis of a modified subcritical zeotropic mixture recuperative high-temperature heat pump
    Guo, Hao
    Gong, Maoqiong
    Qin, Xiaoyu
    [J]. APPLIED ENERGY, 2019, 237 : 338 - 352