Technical note: A simple method for patient-specific quality assurance for lateral targets on a 1.5 T MR-Linac

被引:1
作者
Ferris, William S. [1 ]
Smith, Blake R. [1 ]
Hyer, Daniel E. [1 ]
St-Aubin, Joel J. [1 ,2 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA USA
[2] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
关键词
ArcCheck; MR Linac; PSQA; QA platform 1.5T; unity; CYLINDRICAL DIODE-ARRAY;
D O I
10.1002/acm2.14323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Elekta Unity magnetic resonance (MR) linac is limited to longitudinal couch motion and a sagittal-only laser, which restricts the ability to perform patient-specific quality assurance (PSQA) intensity-modulated radiotherapy (IMRT) measurements for very lateral targets. This work introduces a simple method to perform PSQA using the Sun Nuclear ArcCheck-MR phantom at left and right lateral positions without additional equipment or in-house construction. The proposed setup places the center of the phantom 1.3 cm vertical and 12.9 cm lateral to isocenter in either the left or right direction. Computed tomography (CT) scans are used to simulate the setup and create a QA plan template in the Monaco treatment planning system (TPS). The workflow is demonstrated for four patients, with an average axial distance from the center of the bore to the planning target volume (PTV) of 12.4 cm. Gamma pass rates were above 94% for all plans using global 3%/2 mm gamma criterion with a 10% threshold. Setup uncertainties are slightly larger for the proposed lateral setup compared to the centered setup on the Elekta platform (similar to 1 mm compared to similar to 0.5 mm), but acceptable pass rates are achievable without optimizing shifts in the gamma analysis software. In general, adding the left and right lateral positions increases the axial area in the bore encompassed by the cylindrical measurement array by 147%, substantially increasing the flexibility of measurements for offset targets. Based on this work, we propose using the lateral QA setup if the closest distance to the PTV edge from isocenter is larger than the array radius (10.5 cm) or the percent of the PTV encompassed by the diode array would be increased with the lateral setup compared to the centered setup.
引用
收藏
页数:7
相关论文
共 9 条
[1]   Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task [J].
Brock, Kristy K. ;
Mutic, Sasa ;
McNutt, Todd R. ;
Li, Hua ;
Kessler, Marc L. .
MEDICAL PHYSICS, 2017, 44 (07) :E43-E76
[2]   Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA [J].
Chaswal, Vibha ;
Weldon, Michael ;
Gupta, Nilendu ;
Chakravarti, Arnab ;
Rong, Yi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04) :212-225
[3]   GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform [J].
Hissoiny, Sami ;
Ozell, Benoit ;
Bouchard, Hugo ;
Despres, Philippe .
MEDICAL PHYSICS, 2011, 38 (02) :754-764
[4]   Performance of a cylindrical diode array for use in a 1.5 T MR-linac [J].
Houweling, A. C. ;
de Vries, J. H. W. ;
Wolthaus, J. ;
Woodings, S. ;
Kok, J. G. M. ;
van Asselen, B. ;
Smit, K. ;
Bel, A. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03) :N80-N89
[5]   MRI/linac integration [J].
Lagendijk, Jan J. W. ;
Raaymakers, Bas W. ;
Raaijmakers, Alexander J. E. ;
Overweg, Johan ;
Brown, Kevin J. ;
Kerkhof, Ellen M. ;
van der Put, Richard W. ;
Hardemark, Bjorn ;
van Vutpen, Marco ;
van der Heide, Uutke A. .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) :25-29
[6]   Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218 [J].
Miften, Moyed ;
Olch, Arthur ;
Mihailidis, Dimitris ;
Moran, Jean ;
Pawlicki, Todd ;
Molineu, Andrea ;
Li, Harold ;
Wijesooriya, Krishni ;
Shi, Jie ;
Xia, Ping ;
Papanikolaou, Nikos ;
Low, Daniel A. .
MEDICAL PHYSICS, 2018, 45 (04) :E53-E83
[7]  
Roberts DA, 2021, MED PHYS, V48, P67
[8]   Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience [J].
Snyder, Jeffrey E. ;
St-Aubin, Joel ;
Yaddanapudi, Sridhar ;
Boczkowski, Amanda ;
Dunkerley, David A. P. ;
Graves, Stephen A. ;
Hyer, Daniel E. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07) :160-172
[9]   Analysis of patient-specific quality assurance for Elekta Unity adaptive plans using statistical process control methodology [J].
Strand, Sarah ;
Boczkowski, Amanda ;
Smith, Blake ;
Snyder, Jeffrey E. ;
Hyer, Daniel Ellis ;
Yaddanapudi, Sridhar ;
Dunkerley, David A. P. ;
St-Aubin, Joel .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (04) :99-107