Design advantages and analysis of a novel five-phase doubly-fed induction generator

被引:1
|
作者
Ryndzionek, Roland [1 ]
Michna, Michal [1 ]
Kutt, Filip [1 ]
Kostro, Grzegorz [1 ]
Blecharz, Krzysztof [1 ]
机构
[1] Gdansk Univ Technol, Fac Elect & Control Engn, Gdansk, Poland
关键词
Electrical machine; Computer-aided design; Finite element analysis; Time-domain modeling; Electromechanical energy converter; Doubly fed induction generator; Five-phase generator; Analytical modeling; Winding function approach; Finite element model; Winding generator;
D O I
10.1108/COMPEL-09-2022-0333
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
PurposeThe purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approachThis paper presents the results of a research work related to five-phase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based on the winding function approach. The developed DFIG model was used at the design stage to simulate the generator's no-load and load state. Then, the results of the FEM analysis were shown and compared with the results of laboratory tests of selected DFIG operating states. FindingsThe paper provides the results of analytical and FEM simulation and measurement tests of the new five-phase dual-feed induction generator. The use of the MATLAB Simscape modeling language allows for easy and quick implementation of the model. Design assumptions and analytical model-based analysis have been verified using FEM analysis and measurements performed on the prototype. The results of the presented research validate the design process as well as show the five-phase winding design advantage over the three-phase solution regarding the control winding power quality. Research limitations/implicationsThe main disadvantage of the winding function approach-based model development is the simplification regarding omitting the tangential airgap flux density component. However, this fault only applies to large airgap machines and is insignificant in induction machines. The results of the DFIG analyses were limited to the basic operating states of the generator, i.e. the no-load state, the inductive and resistive load. Practical implicationsThe novel DFIG with five phase rotor control winding can operate as a regular three-phase machine in an electric power generation system and allows for improved control winding power quality of the proposed electrical energy generation system. This increase in power quality is due to the rotor control windings inverter-based PWM supply voltage, which operates with a wider per-phase supply voltage range than a three-phase system. This phenomenon was quantified using control winding current harmonic analysis. Originality/valueThe paper provides the results of analytical and FEM simulation and measurement tests of the new five-phase dual-feed induction generator.
引用
收藏
页码:947 / 962
页数:16
相关论文
共 50 条
  • [31] Unbalanced fault diagnosis of rotor winding in doubly-fed induction generator
    Ma H.-Z.
    Li S.-Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (02): : 138 - 143
  • [32] Nonlinear control of the doubly-fed induction generator in wind power systems
    Soares, Orlando
    Goncalves, Henrique
    Martins, Antonio
    Carvalho, Adriano
    RENEWABLE ENERGY, 2010, 35 (08) : 1662 - 1670
  • [33] Frequency Domain Analysis Method of Forced Power Oscillation Induced by Doubly-fed Induction Generator
    Bo, Chen
    Wei, Zeng
    Wei, He
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [34] Performance analysis of doubly-fed induction generator using PID controller optimised by whale optimisation
    Kashiv, Ashutosh
    Verma, H. K.
    INTERNATIONAL JOURNAL OF ENGINEERING SYSTEMS MODELLING AND SIMULATION, 2024, 15 (04) : 199 - 212
  • [35] Phase Angle Compensation Control Strategy for Low Voltage Ride Through of Doubly-Fed Induction Generator
    Wang, W.
    Chen, N.
    Zhu, L. Z.
    Xu, D. G.
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 991 - +
  • [36] Transient Stability Analysis in Power Systems Integrated with a Doubly-Fed Induction Generator Wind Farm
    Katsivelakis, Michail
    Bargiotas, Dimitrios
    Daskalopulu, Aspassia
    2020 11TH INTERNATIONAL CONFERENCE ON INFORMATION, INTELLIGENCE, SYSTEMS AND APPLICATIONS (IISA 2020), 2020, : 87 - 93
  • [37] Detection of mixed eccentricity fault in doubly-fed induction generator based on reactive power spectrum
    Faiz, Jawad
    Moosavi, Seyed Mohammad Mahdi
    IET ELECTRIC POWER APPLICATIONS, 2017, 11 (06) : 1076 - 1084
  • [38] Educational Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine
    Suwan, M.
    Neumann, T.
    Feltes, C.
    Erlich, I.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [39] CONTROL OF DOUBLY-FED INDUCTION GENERATOR USING ARTIFICIAL NEURAL NETWORK CONTROLLER
    Yaichi, I
    Semmah, A.
    Wira, P.
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2023, 68 (01): : 46 - 51
  • [40] Dynamic phasor modeling of the doubly-fed induction generator under unbalanced conditions
    Demiray, T.
    Milano, F.
    Andersson, G.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1049 - +