Design advantages and analysis of a novel five-phase doubly-fed induction generator

被引:1
|
作者
Ryndzionek, Roland [1 ]
Michna, Michal [1 ]
Kutt, Filip [1 ]
Kostro, Grzegorz [1 ]
Blecharz, Krzysztof [1 ]
机构
[1] Gdansk Univ Technol, Fac Elect & Control Engn, Gdansk, Poland
关键词
Electrical machine; Computer-aided design; Finite element analysis; Time-domain modeling; Electromechanical energy converter; Doubly fed induction generator; Five-phase generator; Analytical modeling; Winding function approach; Finite element model; Winding generator;
D O I
10.1108/COMPEL-09-2022-0333
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
PurposeThe purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approachThis paper presents the results of a research work related to five-phase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based on the winding function approach. The developed DFIG model was used at the design stage to simulate the generator's no-load and load state. Then, the results of the FEM analysis were shown and compared with the results of laboratory tests of selected DFIG operating states. FindingsThe paper provides the results of analytical and FEM simulation and measurement tests of the new five-phase dual-feed induction generator. The use of the MATLAB Simscape modeling language allows for easy and quick implementation of the model. Design assumptions and analytical model-based analysis have been verified using FEM analysis and measurements performed on the prototype. The results of the presented research validate the design process as well as show the five-phase winding design advantage over the three-phase solution regarding the control winding power quality. Research limitations/implicationsThe main disadvantage of the winding function approach-based model development is the simplification regarding omitting the tangential airgap flux density component. However, this fault only applies to large airgap machines and is insignificant in induction machines. The results of the DFIG analyses were limited to the basic operating states of the generator, i.e. the no-load state, the inductive and resistive load. Practical implicationsThe novel DFIG with five phase rotor control winding can operate as a regular three-phase machine in an electric power generation system and allows for improved control winding power quality of the proposed electrical energy generation system. This increase in power quality is due to the rotor control windings inverter-based PWM supply voltage, which operates with a wider per-phase supply voltage range than a three-phase system. This phenomenon was quantified using control winding current harmonic analysis. Originality/valueThe paper provides the results of analytical and FEM simulation and measurement tests of the new five-phase dual-feed induction generator.
引用
收藏
页码:947 / 962
页数:16
相关论文
共 50 条
  • [21] DOUBLY-FED INDUCTION GENERATOR CONTROL DURING UNBALANCED GRID CONDITIONS
    Mendes, Victor F.
    Pereira, Heverton
    Matos, Frederico F.
    Hofmann, Wilfried
    Silva, Selenio R.
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [22] A DOUBLY-FED INDUCTION GENERATOR DRIVE FOR A WIND ENERGY CONVERSION SYSTEM
    Barendse, P. S.
    Pillay, P.
    SAIEE AFRICA RESEARCH JOURNAL, 2006, 97 (04): : 274 - 280
  • [23] Advanced control of a doubly-fed induction generator for wind energy conversion
    Poitiers, F.
    Bouaouiche, T.
    Machmoum, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (07) : 1085 - 1096
  • [24] Design and application of automatic voltage control system in doubly-fed induction generator wind farms
    Chen, H. (chf08@mails.tsinghua.edu.cn), 1600, Automation of Electric Power Systems Press (37): : 15 - 22
  • [25] Grid Forming Stator Flux Control of Doubly-Fed Induction Generator
    Klaes, Norbert
    Poeschke, Florian
    Schulte, Horst
    ENERGIES, 2021, 14 (20)
  • [26] Energy-Based Robust Control of Doubly-Fed Induction Generator
    H. Huerta
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2016, 40 : 23 - 33
  • [27] Converters' Loading Balance and Stability Verification for Doubly-Fed Induction Generator
    Li S.
    CSEE Journal of Power and Energy Systems, 2022,
  • [28] Modelling of doubly-fed induction generator for power system stability study
    Mei, Francoise
    Pal, Bikash C.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 287 - 294
  • [29] Experimental Research of Fuzzy Control for Excitation on Doubly-fed Induction Generator
    Li Lan
    Luan Xiaowei