Transverse and lateral temperature profiles of the window-ejected thermal plume along the facade

被引:8
作者
Sun, Xiepeng [1 ]
Zhang, Xiaolei [1 ,3 ]
Lv, Jiang [1 ]
Chen, Xiaotao [1 ]
Fang, Xiang [1 ]
Tang, Fei [1 ]
Ren, Fei [2 ]
Hu, Longhua [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei, Anhui, Peoples R China
[2] China Acad Safety Sci & Technol, Beijing Key Lab Metro Fire & Passenger Transportat, Beijing 100012, Peoples R China
[3] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 76卷
基金
中国国家自然科学基金;
关键词
Window-ejected thermal plume; Facade fire-proof design; Effective characteristic width and thickness; Transverse temperature profile; Lateral temperature profile; SPILL PLUME; FIRE; COMBUSTION; PROBE;
D O I
10.1016/j.jobe.2023.107303
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The window-ejected thermal plume along the building facade is one of the most classical scientific problems of building fire dynamics, which is an important transition of the fire from the inside of the compartment to the building facade. The present study investigates the temperature profiles and evolutions of the window-ejected thermal plume by experimental and theoretical analysis. The experiments were conducted using a reduced-scale cubic compartment and a facade. Threedimensional (transverse/lateral/vertical) temperature fields are measured and quantified by the thermocouple array considering various heat release rates, window dimensions and its aspect ratios. It is found that: (1) the vertical temperature along the center line of facade first increases then changes a little at the flame region, decreases at the plume region. (2) The transverse or lateral temperature decreases more significantly at the flame region than the plume region. (3) For the flame region, the temperature first changes a little or decreases slightly with increasing transverse distance, however, for the plume region, the temperature first increases, then decreases with increasing transverse distance. A physical model of the window-ejected thermal plume considering the flame and plume regions including characteristic length scales is proposed to describe the transverse and lateral temperature profiles, in which the window characteristic length, effective characteristic width/thickness and the height above the neutral plane are considered in general to reflect temperature profile. The present study provides new observations, experimental data and theoretical analysis of the window-ejected thermal plume temperature profile, which is beneficial for the building facade fire-proof design.
引用
收藏
页数:18
相关论文
共 77 条
  • [1] High-rise building fire safety using mechanical ventilation and stairwell pressurization: A review
    Alianto, Beline
    Nasruddin, N.
    Nugroho, Yulianto Sulistyo
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [2] Influence of window intervals on upward flame spread over discrete polymethyl methacrylate plates in vertical channel of building facades
    An, Weiguang
    Shi, Lei
    Cai, Minglun
    Li, Song
    Peng, Lujun
    Wang, Zhe
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 46
  • [3] AVERAGE CENTERLINE TEMPERATURES OF A BUOYANT POOL FIRE OBTAINED BY IMAGE-PROCESSING OF VIDEO RECORDINGS
    AUDOUIN, L
    KOLB, G
    TORERO, JL
    MOST, JM
    [J]. FIRE SAFETY JOURNAL, 1995, 24 (02) : 167 - 187
  • [4] KRESNIK: A top-down, statistical approach to understand the fire performance of building facades using standard test data
    Bonner, Matthew
    Wegrzynski, Wojciech
    Papis, Bartlomiej K.
    Rein, Guillermo
    [J]. BUILDING AND ENVIRONMENT, 2020, 169
  • [5] A two-thermocouples probe for radiation corrections of measured temperatures in compartment fires
    Brohez, S
    Delvosalle, C
    Marlair, G
    [J]. FIRE SAFETY JOURNAL, 2004, 39 (05) : 399 - 411
  • [6] Experimental study on smoke movement leading to glass damages in double-skinned facade
    Chow, W. K.
    Hung, W. Y.
    Gao, Y.
    Zou, G.
    Dong, H.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (03) : 556 - 566
  • [7] Craighead G., 2009, HIGH RISE SECURITY F, Vthird, DOI [10.1016/b978-1-85617-555-5.x0001-6, DOI 10.1016/B978-1-85617-555-5.X0001-6]
  • [8] Drysdale D., 2011, INTRO FIRE DYNAMICS, VThird, DOI [DOI 10.1002/9781119975465, 10.1002/9781119975465.ch1, DOI 10.1002/9781119975465.CH1]
  • [9] Numerical investigation on window ejected facade flames
    Duny, M.
    Dhima, D.
    Garo, J. P.
    Wang, H. Y.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2016, 8 : 305 - 312
  • [10] Impact of facade type on an ejected flame propagation from a compartment opening-Experimental and numerical studies
    Duny, Mathieu
    Dhima, Dhionis
    Wang, Hui-Ying
    Garo, Jean-Pierre
    Manescau, Brady
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 46