Development of an analytical method for accurate and precise determination of rare earth element concentrations in geological materials using an MC-ICP-MS and group separation

被引:3
|
作者
Lee, Seung-Gu [1 ]
Ko, Kyung-Seok [2 ]
机构
[1] Korea Inst Geosci & Mineral Resources, Geol Div, Daejeon, South Korea
[2] Korea Inst Geosci & Mineral Resources, Groundwater Environm Res Ctr, Daejeon, South Korea
来源
FRONTIERS IN CHEMISTRY | 2023年 / 10卷
关键词
rare earth element; group separation; HIBA; MC-ICP-MS; geological materials; NATURAL-WATER SAMPLES; MASS-SPECTROMETRY; REE; EU; FRACTIONATION; GROUNDWATERS; ANOMALIES; SEDIMENTS; PATTERNS; GRANITES;
D O I
10.3389/fchem.2022.906160
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The concentration of rare earth elements (REEs) in geological materials including SLRS-6 (natural water certified reference material) and JB1b, JA1, and JG2 (Standard Rock Materials of Geological Survey of Japan) can be used as a tracer to characterize various geochemical processes in earth systems. Particularly, accurate and precise determination of rare earth element concentration in natural waters is difficult due to their extremely low concentration and the interference of polyatomic oxides. In this study, we developed a method for accurate and precise determination of the REE (particularly heavy rare earth elements) concentrations in geological materials including natural waters using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) and group separation by 2-hydroxyisobutyric acid (HIBA). The REEs were separated into light rare earth elements (LREEs, La-Ce-Pr-Nd), middle rare earth elements (MREEs, Sm-Eu-Gd-Tb), and heavy rare earth elements (HREEs, Dy-Ho-Er-Tm-Yb-Lu) by a cation-exchange column (AG50W-X8 200-400 mesh) using HIBA. The recovery rates of each REE in the natural water sample exceeded 98%, whereas the recovery rates of each REE in rock materials exceeded 95% except for HREEs. The method developed in this study can accurately measure the REE concentrations (particularly HREE) in geological materials without polyatomic oxide interference during the REE analysis by using the MC-ICP-MS and, thus, can correctly interpret the geochemical implications of REEs in geological systems. The determination of the Sr concentrations and Sr isotopic ratios of SLRS-6 CRM and JB1b, JA1, and JG2 SRMs is also reported, and they are shown to be in good agreement with the recommended values.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479
  • [22] Ion Exchange Chromatography and Mass Bias Correction for Accurate and Precise Zn Isotope Ratio Measurements in Environmental Reference Materials by MC-ICP-MS
    Araujo, Daniel F.
    Boaventura, Geraldo R.
    Viers, Jerome
    Mulholland, Daniel S.
    Weiss, Dominik
    Araujo, Debora
    Lima, Barbara
    Ruiz, Izabel
    Machado, Wilson
    Babinski, Marly
    Dantas, Elton
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (02) : 225 - 235
  • [23] Rapid and accurate determination of gold in geological materials by an improved ICP-MS method
    Tao, Danyang
    Guo, Wei
    Xie, Wenke
    Jin, Lanlan
    Guo, Qinghai
    Hu, Shenghong
    MICROCHEMICAL JOURNAL, 2017, 135 : 221 - 225
  • [24] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    Li, Jin
    Tang, Suohan
    Zhu, Xiangkun
    Ma, Jianxiong
    Zhao, Xinmiao
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2022, 96 (02) : 517 - 524
  • [25] A new digestion and chemical separation technique for rapid and highly reproducible determination of Lu/Hf and Hf isotope ratios in geological materials by MC-ICP-MS
    Bizzarro, M
    Baker, JA
    Ulfbeck, D
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2003, 27 (02): : 133 - 145
  • [26] Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS
    Dong, Lin-Hui
    Wei, Wei
    Yu, Cheng-Long
    Hou, Zhen-Hui
    Zeng, Zhen
    Chen, Tianyu
    Huang, Fang
    ANALYTICAL CHEMISTRY, 2021, 93 (19) : 7172 - 7179
  • [27] Precise measurements of d???????88/86Sr for twenty geological reference materials by double-spike MC-ICP-MS
    Chen, Xu-Qi
    Zeng, Zhen
    Yu, Hui-Min
    Sun, Nan
    Huang, Fang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 479
  • [28] Accurate determination of Cu isotope compositions in Cu-bearing minerals using microdrilling and MC-ICP-MS
    Lv, Nan
    Bao, Zhian
    Chen, Lu
    Chen, Kaiyun
    Zhang, Yan
    Yuan, Honglin
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 457
  • [29] Precise measurement of stable (δ88/86Sr) and radiogenic (87Sr/86Sr) strontium isotope ratios in geological standard reference materials using MC-ICP-MS
    Ma JinLong
    Wei GangJian
    Liu Ying
    Ren ZhongYuan
    Xu YiGang
    Yang YongHong
    CHINESE SCIENCE BULLETIN, 2013, 58 (25): : 3111 - 3118
  • [30] Determination of 226Ra concentrations in seawater and suspended particles (NW Pacific) using MC-ICP-MS
    Bourquin, M.
    van Beek, P.
    Reyss, J. L.
    Riotte, J.
    Freydier, R.
    MARINE CHEMISTRY, 2011, 126 (1-4) : 132 - 138