Dual-emission fluorescence detection of histidine using carbon dots and calcein/Ni2+complexes

被引:5
作者
Liu, Jinshui [1 ]
Song, Bo [1 ]
Fu, Ting [1 ]
机构
[1] Anhui Normal Univ, Coll Chem & Mat Sci, Anhui Key Lab Chemo Biosensing, Key Lab Funct Mol Solids,Minist Educ, Wuhu 241000, Peoples R China
关键词
Ratiometric fluorescence; Carbon dots; Histidine; Calcein; SULFIDE QUANTUM DOTS; SELECTIVE DETECTION; POLYMER NANOPARTICLES; SENSITIVE DETECTION; PROBE; NANOCLUSTERS; NANOPROBE; COPPER; ASSAY;
D O I
10.1016/j.saa.2022.121951
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Histidine (His) is a natural amino acid that plays very important roles in biota. However, the low concentrations of His in biological fluids and the similar structures and properties of other amino acids mean it is difficult to selectively determine His concentrations in biological fluids with a high degree of sensitivity. A novel ratiometric fluorescence probe for detecting His in aqueous solutions is described here. The method involves carbon dots (CDs) and calcein/Ni2+ complexes. At an excitation wavelength of 480 nm, the CD/calcein system emits green fluorescence (maximum emission from calcein at 512 nm) and red fluorescence (maximum emission from CDs at 617 nm). The presence of Ni2+ decreases the calcein fluorescence intensity because of static quenching caused by the formation of calcein/Ni2+ complexes but the CD fluorescence intensity remains almost unchanged. Fluo-rescence of calcein/Ni2+ complexes provides the response, and the presence of His binds to Ni2+ via cooperative chelation and produces free calcein causing fluorescence to be recovered. CDs provide a self-calibration fluo-rescence signal, the intensity of which remains almost unchanged in the presence of His. The ratio of the fluo-rescence intensities at 512 and 617 nm (I512/I617) was strongly related to the His concentration in the range 0.5-22 mu M, and the detection limit was 0.16 mu M. The specificity of Ni2+/His interactions allows His to be determined without interference from other species. The method was successfully used to determine His in diluted human urine. The recovery was acceptable, suggesting that the biosensor can be used to determine His in real samples.
引用
收藏
页数:6
相关论文
共 36 条
[1]   An Ultrasensitive Turn-On Ratiometric Fluorescent Probes for Detection of Ag+ Based On Carbon Dots/SiO2 and Gold Nanoclusters [J].
An, Jia ;
Chen, Rubing ;
Chen, Meizhu ;
Hu, Yongqin ;
Lyu, Ying ;
Liu, Yufei .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
[2]   Doped zinc sulfide quantum dots based phosphorescence turn-off/on probe for detecting histidine in biological fluid [J].
Bian, Wei ;
Wang, Fang ;
Wei, Yanli ;
Wang, Li ;
Liu, Qiaoling ;
Dong, Wenjuan ;
Shuang, Shaomin ;
Choi, Martin M. F. .
ANALYTICA CHIMICA ACTA, 2015, 856 :82-89
[3]   A ratiometric fluorescent assay for the detection and bioimaging of alkaline phosphatase based on near infrared Ag2S quantum dots and calcein [J].
Cai, Meifang ;
Ding, Caiping ;
Wang, Fangfang ;
Ye, Mingqiang ;
Zhang, Cuiling ;
Xian, Yuezhong .
BIOSENSORS & BIOELECTRONICS, 2019, 137 :148-153
[4]   Histidine-triggered turning-on of gold/copper nanocluster fluorescence for the sensitive and selective detection of histidine [J].
Cai, Yuanyuan ;
Wang, Jin ;
Liu, Chongyang ;
Yang, Shuqing ;
Zhang, Yujiao ;
Liu, Aihua .
CHEMICAL COMMUNICATIONS, 2020, 56 (78) :11637-11640
[5]   Enzyme-free fluorescence determination of uric acid and trace Hg(II) in serum using Si/N doped carbon dots [J].
Cao, Dan ;
Luo, Ya-Xiong ;
Liu, Wei-Ping ;
Li, Yong-Sheng ;
Gao, Xiu-Feng .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 263
[6]   A highly selective semiconducting polymer dots-based "off-on" fluorescent nanoprobe for iron, copper and histidine detection and imaging in living cells [J].
Chabok, Ammar ;
Shamsipur, Mojtaba ;
Yeganeh-Faal, Ali ;
Molaabasi, Fatemeh ;
Molaei, Karam ;
Sarparast, Morteza .
TALANTA, 2019, 194 :752-762
[7]   Molecularly imprinted photonic hydrogel sensor for optical detection of L-histidine [J].
Chen, Qianshan ;
Shi, Wenhui ;
Cheng, Meifang ;
Liao, Shuzhen ;
Zhou, Jun ;
Wu, Zhaoyang .
MICROCHIMICA ACTA, 2018, 185 (12)
[8]   Dual-mode turn-on ratiometric fluorescence sensor based on carbon dots and CuInS2/ZnS quantum dots for detection of chlorotetracycline [J].
Chen, Xiaoping ;
Lin, Jianwei ;
Zhuang, Yafeng ;
Huang, Siqi ;
Chen, Jinghua ;
Han, Zhizhong .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 270
[9]   A fluorometric histidine biosensor based on the use of a quencher-labeled Cu(II)-dependent DNAzyme [J].
Chen, Zhuling ;
He, Qun ;
Zhao, Mengmeng ;
Lin, Cuiying ;
Luo, Fang ;
Lin, Zhenyu ;
Chen, Guonan .
MICROCHIMICA ACTA, 2017, 184 (10) :4015-4020
[10]   Full-Color Light-Emitting Carbon Dots with a Surface-State-Controlled Luminescence Mechanism [J].
Ding, Hui ;
Yu, Shang-Bo ;
Wei, Ji-Shi ;
Xiong, Huan-Ming .
ACS NANO, 2016, 10 (01) :484-491