Wear, Osteolysis, and Aseptic Loosening Following Total Hip Arthroplasty in Young Patients with Highly Cross-Linked Polyethylene: A Review of Studies with a Follow-Up of over 15 Years

被引:4
作者
Deans, Christopher F. [1 ]
Buckner, Brandt C. [1 ]
Garvin, Kevin L. [1 ]
机构
[1] Univ Nebraska Med Ctr, Dept Orthopaed Surg & Rehabil, 985640 Nebraska Med Ctr, Omaha, NE 68198 USA
关键词
highly cross-linked polyethylene; total hip arthroplasty; young arthroplasty; polyethylene wear; ACETABULAR COMPONENT; BIOLOGICAL-ACTIVITY; REVISION SURGERY; UNITED-STATES; MINIMUM; CEMENTLESS; RATES; THA; MULTICENTER; FIXATION;
D O I
10.3390/jcm12206615
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Total hip arthroplasty (THA) has in recent years trended toward a younger, more physically demanding patient population. Mid- to long-term studies of all ages of THA patients using highly cross-linked polyethylene (HXLPE) have been favorable, but concerns about its long-term failure and wear-related complications remain for young THA patients. In this narrative review, a search of the PubMed/MEDLINE and Cochrane databases was performed, and we identified six studies with a minimum 15-year follow-up of HXLPE with various femoral head materials. Wear-related revisions were exceedingly low for patients under the age of 55, with variable reports of non-clinically significant osteolysis. Higher activity levels, a larger femoral head size, and femoral head material were not associated with greater long-term wear rates. Young THA with metal or ceramic on HXLPE is exceedingly durable with favorable outcomes at follow-ups of over 15 years.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?
    Glyn-Jones, Sion
    Saac, Sherif
    Hauptfleisch, Jennifer
    McLardy-Smith, Peter
    Murray, David W.
    Singh, Harinderjit
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03) : 337 - 343
  • [22] In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty
    Manning, DW
    Chiang, PP
    Martell, JM
    Galante, JO
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07) : 880 - 886
  • [23] Gender Differences in Wear Rates for 28-vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty
    Stambough, Jeffrey B.
    Pashos, Gail
    Wu, Ningying
    Haynes, Jacob A.
    Martell, John M.
    Clohisy, John C.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04) : 899 - 905
  • [24] Highly Cross-Linked Polyethylene in Patients 50 Years of Age and Younger: A 20-year Follow-Up Analysis
    Zitsch, Bradford P.
    Cahoy, Kevin M.
    Urban, Nathanael D.
    Buckner, Brandt C.
    Garvin, Kevin L.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09) : S145 - S152
  • [25] Highly Cross-linked Polyethylene Provides Decreased Osteolysis and Reoperation at Minimum 10-Year Follow-Up
    Lachiewicz, Paul F.
    Soileau, Elizabeth S.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (09) : 1959 - 1962
  • [26] Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Samujh, Christopher
    Bhimani, Samrath
    Smith, Langan
    Malkani, Arthur L.
    ORTHOPEDICS, 2016, 39 (06) : E1178 - E1182
  • [27] Cementless Total Hip Arthroplasty With Alumina-on-Highly Cross-Linked Polyethylene Bearing in Young Patients With Femoral Head Osteonecrosis
    Kim, Young-Hoo
    Choi, Yoowang
    Kim, Jun-Shik
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02) : 218 - 223
  • [28] Wear rate and osteolysis in two types of second-generation annealed highly cross-linked polyethylene in total hip arthroplasty: A retrospective comparative study with a minimum of five years
    Yamamoto, Naoki
    Takada, Ryohei
    Jinno, Tetsuya
    Miyatake, Kazumasa
    Watanabe, Naoto
    Koga, Hideyuki
    Yoshii, Toshitaka
    Yagishita, Kazuyoshi
    Okawa, Atsushi
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (01)
  • [29] In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty
    Nishimura, Manase
    Nakamura, Takuya
    Nishida, Hideji
    Misaki, Tomonori
    Aikawa, Takao
    JOURNAL OF ARTHROPLASTY, 2024, 39 (12) : 3092 - 3096
  • [30] Minimum five-year wear rate of metal-on-highly cross-linked polyethylene in primary total hip arthroplasty
    Scemama, Caroline
    Dora, Claudio
    Langlois, Jean
    Hamadouche, Moussa
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) : 1051 - 1055