Multiple Brain Metastases Radiosurgery with CyberKnife Device: Dosimetric Comparison between Fixed/Iris and Multileaf Collimator Plans

被引:2
|
作者
Ianiro, Anna [1 ]
Infusino, Erminia [1 ]
D'Andrea, Marco [1 ]
Marucci, Laura [2 ]
Farneti, Alessia [2 ]
Sperati, Francesca [3 ]
Cassano, Bartolomeo [1 ]
Ungania, Sara [1 ]
Soriani, Antonella [1 ]
机构
[1] IRCCS Regina Elena Natl Canc Inst, Dept Med Phys, Rome, Italy
[2] IRCCS Regina Elena Natl Canc Inst IFO, Dept Radiat Oncol, Rome, Italy
[3] IRCCS San Gallicano Dermatol Inst IFO, Dept Biostat & Bioinformat, Clin Trial Ctr, Rome, Italy
关键词
Brain radiosurgery; CyberKnife (R); dosimetric comparison; BODY RADIATION-THERAPY; STEREOTACTIC RADIOSURGERY; QUALITY-ASSURANCE; RADIOTHERAPY; SURVIVAL; SYSTEM; IRRADIATION; NUMBER; CANCER;
D O I
10.4103/jmp.jmp_82_22
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In our institution, stereotactic radiosurgery of multiple brain metastases is performed with the CyberKnife (R) (CK) device, using fixed/Iris collimators. In this study, nineteen fixed/Iris plans were recalculated with the multileaf collimator (MLC), to assess if it is possible to produce plans with comparable dosimetric overall quality. Materials and Methods: For consistent comparisons, MLC plans were re-optimized and re-normalized in order to achieve the same minimum dose for the total planning target volume (PTVtot). Conformation number (CN), homogeneity index (HI) and dose gradient index (DGI) metrics were evaluated. The dose to the brain was evaluated as the volume receiving 12 Gy (V-12) and as the integral dose (ID). The normal tissue complication probability (NTCP) for brain radionecrosis was calculated as a function of V-12. Results: The reoptimized plans were reviewed by the radiation oncologist and were found clinically acceptable according to the The American Association of Physicists in Medicine (AAPM) Task Group-101 protocol. However, fixed/Iris plans provided significantly higher CN (+8.6%), HI (+2.2%), and DGI (+44.0%) values, and significantly lower ID values (-35.9%). For PTVtot less than the median value of 2.58cc, fixed/Iris plans provided significantly lower NTCP values. On the other side, MLC plans provided significantly lower treatment times (-18.4%), number of monitor units (-33.3%), beams (-46.0%) and nodes (-21.3%). Conclusions: CK-MLC plans for the stereotactic treatment of brain multi metastases could provide an important advantage in terms of treatment duration. However, to contain the increased risk for brain radionecrosis, it could be useful to calculate MLC plans only for patients with large PTVtot.
引用
收藏
页码:120 / 128
页数:9
相关论文
共 50 条
  • [31] Multi-Institutional Dosimetric Evaluation of Modern Day Stereotactic Radiosurgery (SRS) Treatment Options for Multiple Brain Metastases
    Vergalasova, Irina
    Liu, Haisong
    Alonso-Basanta, Michelle
    Dong, Lei
    Li, Jun
    Nie, Ke
    Shi, Wenyin
    Teo, Boon-Keng Kevin
    Yu, Yan
    Yue, Ning Jeff
    Zou, Wei
    Li, Taoran
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [32] Dosimetric Comparison of Brain Sparing Between HyperArc and GammaKnife for Single to Triple Brain Metastases
    Ueda, Yoshihiro
    Mori, Kanji
    Ohira, Shingo
    Tarutani, Kazuo
    Kanayama, Naoyuki
    Okamura, Ayako
    Konishi, Koji
    ANTICANCER RESEARCH, 2025, 45 (04) : 1631 - 1641
  • [33] Linac-based radiosurgery for multiple brain metastases: Comparison between two mono-isocenter techniques with multiple non-coplanar arcs
    Ruggieri, Ruggero
    Naccarato, Stefania
    Mazzola, Rosario
    Ricchetti, Francesco
    Corradini, Stefanie
    Fiorentino, Alba
    Alongi, Filippo
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 70 - 78
  • [34] A comparison between cyberknife and neurosurgery in solitary brain metastases from non-small cell lung cancer
    Tian, Li-Jun
    Zhuang, Hong-Qing
    Yuan, Zhi-Yong
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2013, 115 (10) : 2009 - 2014
  • [35] Verification of stereotactic radiosurgery plans for multiple brain metastases using a virtual phantom-based procedure
    Calvo-Ortega, Juan-Francisco
    Greer, Peter B.
    Moragues-Femenia, Sandra
    Pozo-Masso, Miguel
    Casals-Farran, Joan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (03) : 449 - 457
  • [36] Dosimetric comparison of Synchrony® real-time motion tracking treatment plans between CyberKnife robotic radiosurgery and Radixact system for stereotactic body radiation therapy of lung and prostate cancer
    Kong, C. W.
    Chiu, T. L.
    Geng, H.
    Lam, W. W.
    Yang, B.
    Cheung, C. W.
    Yu, S. K.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [37] Noninvasive cardiac radioablation for ventricular tachycardia: dosimetric comparison between linear accelerator- and robotic CyberKnife-based radiosurgery systems
    Wang, Ching-Yu
    Ho, Li-Ting
    Lin, Lian-Yu
    Chan, Hsing-Min
    Chen, Hung-Yi
    Yu, Tung-Lin
    Huang, Yu-Sen
    Kuo, Sung-Hsin
    Lee, Wen-Jeng
    Chen, Jenny Ling-Yu
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [38] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Giorgio Hamid Raza
    Luca Capone
    Paolo Tini
    Martina Giraffa
    Piercarlo Gentile
    Giuseppe Minniti
    Radiation Oncology, 17
  • [39] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Raza, Giorgio Hamid
    Capone, Luca
    Tini, Paolo
    Giraffa, Martina
    Gentile, Piercarlo
    Minniti, Giuseppe
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [40] Dosimetric comparison of 2.5 mm vs. 3.0 mm leaf width micro-multileaf collimator-based treatment systems for intracranial stereotactic radiosurgery using dynamic conformal arcs: implications for treatment planning
    Ohtakara, Kazuhiro
    Hayashi, Shinya
    Tanaka, Hidekazu
    Hoshi, Hiroaki
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (09) : 630 - 638