Multiple Brain Metastases Radiosurgery with CyberKnife Device: Dosimetric Comparison between Fixed/Iris and Multileaf Collimator Plans

被引:2
|
作者
Ianiro, Anna [1 ]
Infusino, Erminia [1 ]
D'Andrea, Marco [1 ]
Marucci, Laura [2 ]
Farneti, Alessia [2 ]
Sperati, Francesca [3 ]
Cassano, Bartolomeo [1 ]
Ungania, Sara [1 ]
Soriani, Antonella [1 ]
机构
[1] IRCCS Regina Elena Natl Canc Inst, Dept Med Phys, Rome, Italy
[2] IRCCS Regina Elena Natl Canc Inst IFO, Dept Radiat Oncol, Rome, Italy
[3] IRCCS San Gallicano Dermatol Inst IFO, Dept Biostat & Bioinformat, Clin Trial Ctr, Rome, Italy
关键词
Brain radiosurgery; CyberKnife (R); dosimetric comparison; BODY RADIATION-THERAPY; STEREOTACTIC RADIOSURGERY; QUALITY-ASSURANCE; RADIOTHERAPY; SURVIVAL; SYSTEM; IRRADIATION; NUMBER; CANCER;
D O I
10.4103/jmp.jmp_82_22
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In our institution, stereotactic radiosurgery of multiple brain metastases is performed with the CyberKnife (R) (CK) device, using fixed/Iris collimators. In this study, nineteen fixed/Iris plans were recalculated with the multileaf collimator (MLC), to assess if it is possible to produce plans with comparable dosimetric overall quality. Materials and Methods: For consistent comparisons, MLC plans were re-optimized and re-normalized in order to achieve the same minimum dose for the total planning target volume (PTVtot). Conformation number (CN), homogeneity index (HI) and dose gradient index (DGI) metrics were evaluated. The dose to the brain was evaluated as the volume receiving 12 Gy (V-12) and as the integral dose (ID). The normal tissue complication probability (NTCP) for brain radionecrosis was calculated as a function of V-12. Results: The reoptimized plans were reviewed by the radiation oncologist and were found clinically acceptable according to the The American Association of Physicists in Medicine (AAPM) Task Group-101 protocol. However, fixed/Iris plans provided significantly higher CN (+8.6%), HI (+2.2%), and DGI (+44.0%) values, and significantly lower ID values (-35.9%). For PTVtot less than the median value of 2.58cc, fixed/Iris plans provided significantly lower NTCP values. On the other side, MLC plans provided significantly lower treatment times (-18.4%), number of monitor units (-33.3%), beams (-46.0%) and nodes (-21.3%). Conclusions: CK-MLC plans for the stereotactic treatment of brain multi metastases could provide an important advantage in terms of treatment duration. However, to contain the increased risk for brain radionecrosis, it could be useful to calculate MLC plans only for patients with large PTVtot.
引用
收藏
页码:120 / 128
页数:9
相关论文
共 50 条
  • [1] Dosimetric comparison between cone/Iris-based and InCise MLC-based CyberKnife plans for single and multiple brain metastases
    Jang, Si Young
    Lalonde, Ron
    Ozhasoglu, Cihat
    Burton, Steven
    Heron, Dwight
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 184 - 199
  • [2] A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis
    Greto, Daniela
    Pallotta, Stefania
    Masi, Laura
    Talamonti, Cinzia
    Marrazzo, Livia
    Doro, Raffaella
    Saieva, Calogero
    Scoccianti, Silvia
    Desideri, Isacco
    Livi, Lorenzo
    RADIOLOGIA MEDICA, 2017, 122 (05): : 392 - 397
  • [3] Dosimetric comparison of fractionated radiosurgery plans using frameless Gamma Knife ICON and CyberKnife systems with linear accelerator-based radiosurgery plans for multiple large brain metastases
    Han, Eun Young
    Wang, He
    Luo, Dershan
    Li, Jing
    Wang, Xin
    JOURNAL OF NEUROSURGERY, 2020, 132 (05) : 1473 - 1479
  • [4] Dosimetric comparison of HyperArc and InCise MLC-based CyberKnife plans in treating single and multiple brain metastases
    Zhu, Liying
    Dong, Shengnan
    Sun, Lei
    Xiao, Yixuan
    Zhong, Yihua
    Pan, Mingyuan
    Wang, Yang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [5] A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis
    Daniela Greto
    Stefania Pallotta
    Laura Masi
    Cinzia Talamonti
    Livia Marrazzo
    Raffaella Doro
    Calogero Saieva
    Silvia Scoccianti
    Isacco Desideri
    Lorenzo Livi
    La radiologia medica, 2017, 122 : 392 - 397
  • [6] Single isocenter dynamic conformal arcs-based radiosurgery for brain metastases: Dosimetric comparison with Cyberknife and clinical investigation
    Oshiro, Yoshiko
    Mizumoto, Masashi
    Kato, Yuichi
    Tsuchida, Yukihiro
    Tsuboi, Koji
    Sakae, Takeji
    Sakurai, Hideyuki
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 29
  • [7] Robotic radiosurgery versus micro-multileaf collimator: a dosimetric comparison for large or critically located arteriovenous malformations
    Blamek, Slawomir
    Grzadziel, Aleksandra
    Miszczyk, Leszek
    RADIATION ONCOLOGY, 2013, 8
  • [8] Overview of dosimetric and biological perspectives on radiosurgery of multiple brain metastases in comparison with whole brain radiotherapy
    Xue, Jinyu
    LaCouture, Tamara
    Grimm, Jimm
    Goldman, H. Warren
    Ibbott, Geoffrey S.
    Yorke, Ellen
    Kubicek, Gregory J.
    JOURNAL OF RADIOSURGERY AND SBRT, 2015, 3 (04): : 271 - 279
  • [9] Dosimetric Comparison of Treatment Plans Computed With Finite Size Pencil Beam and Monte Carlo Algorithms Using the InCise™ Multileaf Collimator-Equipped Cyberknife® System
    Dona, Kalpani Nisansala Udeni Galpayage
    Shang, Charles
    Leventouri, Theodora
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (01) : 7 - 15
  • [10] Intensity-modulated radiosurgery with rapidarc for multiple brain metastases and comparison with static approach
    Wang, Jia-Zhu
    Pawlicki, Todd
    Rice, Roger
    Mundt, Arno J.
    Sandhu, Ajay
    Lawson, Joshua
    Murphy, Kevin T.
    MEDICAL DOSIMETRY, 2012, 37 (01) : 31 - 36