Simultaneous multislice diffusion-weighted imaging versus standard diffusion-weighted imaging in whole-body PET/MRI

被引:4
作者
Furtado, Felipe S. [1 ,2 ]
Mercaldo, Nathaniel D. [1 ]
Vahle, Thomas [3 ]
Benkert, Thomas [3 ]
Bradley, William R. [1 ]
Ratanaprasatporn, Lisa [4 ]
Seethamraju, Ravi Teja [2 ,5 ]
Harisinghani, Mukesh G. [1 ]
Lee, Susanna [1 ]
Suarez-Weiss, Krista [4 ]
Umutlu, Lale [6 ]
Catana, Ciprian [1 ,2 ]
Pomykala, Kelsey L. [6 ]
Domachevsky, Liran [7 ,8 ]
Bernstine, Hanna [8 ,9 ]
Groshar, David [8 ,9 ]
Rosen, Bruse R. [2 ]
Catalano, Onofrio Antonio [1 ,2 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St, Boston, MA 02114 USA
[2] Harvard Med Sch, Athinoula A Martinos Ctr Biomed Imaging, 149 13th St, Charlestown, MA 02129 USA
[3] Siemens Healthcare GmbH, MR Applicat Predev, Allee Roethelheimpk 2, D-91052 Erlangen, Germany
[4] Harvard Med Sch, Brigham & Womens Hosp, 75 Francis St, Boston, MA 02115 USA
[5] Siemens Med Solut USA Inc, MR Collaborat, 30 Jonathan Ln, Malden, MA 02148 USA
[6] Univ Med Essen, Hufelandstr 55, D-45147 Essen, Germany
[7] Sheba Med Ctr, Derech Sheba 2, Ramat Gan, Israel
[8] Tel Aviv Univ, IL-6997801 Tel Aviv, Israel
[9] Assuta Med Ctr, HaBarzel 20 St, Tel Aviv, Israel
关键词
DWI; Echo-planar imaging; Parallel imaging; Diffusion magnetic resonance imaging; Multiband; EMISSION TOMOGRAPHY/MAGNETIC RESONANCE; NEUROENDOCRINE TUMORS; MULTIPARAMETRIC MRI; INTEGRATED PET/MRI; FOLLOW-UP; HEAD; PET/CT; NECK; DIAGNOSIS; LIVER;
D O I
10.1007/s00330-022-09275-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare standard (STD-DWI) single-shot echo-planar imaging DWI and simultaneous multislice (SMS) DWI during whole-body positron emission tomography (PET)/MRI regarding acquisition time, image quality, and lesion detection.Methods Eighty-three adults (47 females, 57%), median age of 64 years (IQR 52-71), were prospectively enrolled from August 2018 to March 2020. Inclusion criteria were (a) abdominal or pelvic tumors and (b) PET/MRI referral from a clinician. Patients were excluded if whole-body acquisition of STD-DWI and SMS-DWI sequences was not completed. The evaluated sequences were axial STD-DWI at b-values 50-400-800 s/mm(2) and the apparent diffusion coefficient (ADC), and axial SMS-DWI at b-values 50-300-800 s/mm(2) and ADC, acquired with a 3-T PET/MRI scanner. Three radiologists rated each sequence's quality on a five-point scale. Lesion detection was quantified using the anatomic MRI sequences and PET as the reference standard. Regression models were constructed to quantify the association between all imaging outcomes/scores and sequence type.Results The median whole-body STD-DWI acquisition time was 14.8 min (IQR 14.1-16.0) versus 7.0 min (IQR 6.7-7.2) for whole-body SMS-DWI, p < 0.001. SMS-DWI image quality scores were higher than STD-DWI in the abdomen (OR 5.31, 95% CI 2.76-10.22, p < 0.001), but lower in the cervicothoracic junction (OR 0.21, 95% CI 0.10-0.43, p < 0.001). There was no significant difference in the chest, mediastinum, pelvis, and rectum. STD-DWI detected 276/352 (78%) lesions while SMS-DWI located 296/352 (84%, OR 1.46, 95% CI 1.02-2.07, p = 0.038).Conclusions In cancer staging and restaging, SMS-DWI abbreviates acquisition while maintaining or improving the diagnostic yield in most anatomic regions.
引用
收藏
页码:2536 / 2547
页数:12
相关论文
共 74 条
[1]   Comparison of PET/MRI With PET/CT in the Evaluation of Disease Status in Lymphoma [J].
Afaq, Asim ;
Fraioli, Francesco ;
Sidhu, Harbir ;
Wan, Simon ;
Punwani, Shonit ;
Chen, Shih-hsin ;
Akin, Oguz ;
Linch, David ;
Ardeshna, Kirit ;
Lambert, Jonathan ;
Miles, Kenneth ;
Groves, Ashley ;
Kayani, Irfan .
CLINICAL NUCLEAR MEDICINE, 2017, 42 (01) :E1-E7
[2]   Comparison of PET/CT and PET/MRI hybrid systems using a 68Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience [J].
Afshar-Oromieh, A. ;
Haberkorn, U. ;
Schlemmer, H. P. ;
Fenchel, M. ;
Eder, M. ;
Eisenhut, M. ;
Hadaschik, B. A. ;
Kopp-Schneider, A. ;
Roethke, M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (05) :887-897
[3]   Clinical impact of PET/MR in treated colorectal cancer patients [J].
Amorim, Barbara J. ;
Hong, Theodore S. ;
Blaszkowsky, Lawrence S. ;
Ferrone, Cristina R. ;
Berger, David L. ;
Bordeianou, Liliana G. ;
Ricciardi, Rocco ;
Clark, Jeffrey W. ;
Ryan, David P. ;
Wo, Jennifer Y. ;
Qadan, Motaz ;
Vangel, Mark ;
Umutlu, Lale ;
Groshar, David ;
Canamaques, Lina G. ;
Gervais, Debra A. ;
Mahmood, Umar ;
Rosen, Bruce R. ;
Catalano, Onofrio A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (11) :2260-2269
[4]   Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients [J].
Atkinson, Wendy ;
Catana, Ciprian ;
Abramson, Jeremy S. ;
Arabasz, Grae ;
McDermott, Shanaugh ;
Catalano, Onofrio ;
Muse, Victorine ;
Blake, Michael A. ;
Barnes, Jeffrey ;
Shelly, Martin ;
Hochberg, Ephraim ;
Rosen, Bruce R. ;
Guimaraes, Alexander R. .
ABDOMINAL RADIOLOGY, 2016, 41 (07) :1338-1348
[5]   Local recurrence of squamous cell carcinoma of the head and neck after radio(chemo)therapy: Diagnostic performance of FDG-PET/MRI with diffusion-weighted sequences [J].
Becker, Minerva ;
Varoquaux, Arthur D. ;
Combescure, Christophe ;
Rager, Olivier ;
Pusztaszeri, Marc ;
Burkhardt, Karim ;
Delattre, Benedicte M. A. ;
Dulguerov, Pavel ;
Dulguerov, Nicolas ;
Katirtzidou, Eirini ;
Caparrotti, Francesca ;
Ratib, Osman ;
Zaidi, Habib ;
Becker, Christoph D. .
EUROPEAN RADIOLOGY, 2018, 28 (02) :651-663
[6]   Simultaneous 68Ga-DOTATOC PET/MRI in Patients With Gastroenteropancreatic Neuroendocrine Tumors Initial Results [J].
Beiderwellen, Karsten J. ;
Poeppel, Thorsten D. ;
Hartung-Knemeyer, Verena ;
Buchbender, Christian ;
Kuehl, Hilmar ;
Bockisch, Andreas ;
Lauenstein, Thomas C. .
INVESTIGATIVE RADIOLOGY, 2013, 48 (05) :273-279
[7]   Diagnosis of Hepatic Metastasis: Comparison of Respiration-Triggered Diffusion-Weighted Echo-Planar MRI and Five T2-Weighted Turbo Spin-Echo Sequences [J].
Bruegel, Melanie ;
Gaa, Jochen ;
Waldt, Simone ;
Woertler, Klaus ;
Holzapfel, Konstantin ;
Kiefer, Berthold ;
Rummeny, Ernst J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) :1421-1429
[8]   Improving staging of rectal cancer in the pelvis: the role of PET/MRI [J].
Catalano, Onofrio A. ;
Lee, Susanna I. ;
Parente, Chiara ;
Cauley, Christy ;
Furtado, Felipe S. ;
Striar, Robin ;
Soricelli, Andrea ;
Salvatore, Marco ;
Li, Yan ;
Umutlu, Lale ;
Canamaque, Lina Garcia ;
Groshar, David ;
Mahmood, Umar ;
Blaszkowsky, Lawrence S. ;
Ryan, David P. ;
Clark, Jeffrey W. ;
Wo, Jennifer ;
Hong, Theodore S. ;
Kunitake, Hiroko ;
Bordeianou, Liliana ;
Berger, David ;
Ricciardi, Rocco ;
Rosen, Bruce .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (04) :1235-1245
[9]   Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast [J].
Catalano, Onofrio Antonio ;
Daye, Dania ;
Signore, Alberto ;
Iannace, Carlo ;
Vangel, Mark ;
Luongo, Angelo ;
Catalano, Marco ;
Filomena, Mazzeo ;
Mansi, Luigi ;
Soricelli, Andrea ;
Salvatore, Marco ;
Fuin, Niccolo ;
Catana, Ciprian ;
Mahmood, Umar ;
Rosen, Bruce Robert .
INTERNATIONAL JOURNAL OF ONCOLOGY, 2017, 51 (01) :281-288
[10]   PET/MR in invasive ductal breast cancer: correlation between imaging markers and histological phenotype [J].
Catalano, Onofrio Antonio ;
Horn, Gary Lloyd ;
Signore, Alberto ;
Iannace, Carlo ;
Lepore, Maria ;
Vangel, Mark ;
Luongo, Angelo ;
Catalano, Marco ;
Lehman, Constance ;
Salvatore, Marco ;
Soricelli, Andrea ;
Catana, Ciprian ;
Mahmood, Umar ;
Rosen, Bruce Robert .
BRITISH JOURNAL OF CANCER, 2017, 116 (07) :893-902