Monte-Carlo techniques for radiotherapy applications II: equipment and source modelling, dose calculations and radiobiology

被引:2
|
作者
Fielding, Andrew L. [1 ]
机构
[1] Queensland Univ Technol QUT, Sch Chem & Phys, Brisbane, Australia
关键词
Monte-Carlo simulation; radiotherapy; radiation; dosimetry; CONE-BEAM CT; X-RAY TUBE; CLINICAL IMPLEMENTATION; HELICAL TOMOTHERAPY; PATIENT DOSIMETRY; ELECTRON-BEAMS; TOPAS-NBIO; SIMULATION; RADIATION; PHOTON;
D O I
10.1017/S1460396923000080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction:This is the second of two papers giving an overview of the use of Monte-Carlo techniques for radiotherapy applications. Methods:The first paper gave an introduction and introduced some of the codes that are available to the user wishing to model the different aspects of radiotherapy treatment. It also aims to serve as a useful companion to a curated collection of papers on Monte-Carlo that have been published in this journal. Results and Conclusions:This paper focuses on the application of Monte-Carlo to specific problems in radiotherapy. These include radiotherapy and imaging beam production, brachytherapy, phantom and patient dosimetry, detector modelling and track structure calculations for micro-dosimetry, nano-dosimetry and radiobiology.
引用
收藏
页数:6
相关论文
共 33 条
  • [21] A photon source model based on particle transport in a parameterized accelerator structure for Monte Carlo dose calculations
    Ishizawa, Yoshiki
    Dobashi, Suguru
    Kadoya, Noriyuki
    Ito, Kengo
    Chiba, Takahito
    Takayama, Yoshiki
    Sato, Kiyokazu
    Takeda, Ken
    MEDICAL PHYSICS, 2018, 45 (07) : 2937 - 2946
  • [22] Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations
    Bohm, TD
    Mourtada, FA
    Das, RK
    MEDICAL PHYSICS, 2001, 28 (08) : 1770 - 1775
  • [23] Validating a double Gaussian source model for small proton fields in a commercial Monte-Carlo dose calculation engine
    Kugel, Fabian
    Wulff, Jorg
    Baeumer, Christian
    Janson, Martin
    Kretschmer, Jana
    Brodbek, Leonie
    Behrends, Carina
    Verbeek, Nico
    Looe, Hui Khee
    Poppe, Bjorn
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (04): : 529 - 541
  • [24] MONTE-CARLO CALCULATIONS OF MONOENERGETIC ELECTRON DEPTH-DOSE DISTRIBUTIONS IN LIF CHIPS - SKIN DOSE CORRECTION FACTORS FOR BETA-RAYS
    HOROWITZ, YS
    HIRNING, CR
    YUEN, P
    WONG, P
    HEALTH PHYSICS, 1994, 67 (04): : 330 - 337
  • [25] Monte Carlo-based dose calculation for (32) P patch source for superficial brachytherapy applications
    Sahoo, Sridhar
    Palani, Selvam T.
    Saxena, S. K.
    Babu, D. A. R.
    Dash, A.
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 13 - 17
  • [26] Radiotherapy dose calculations in high-Z materials: comprehensive comparison between experiment, Monte Carlo, and conventional planning algorithms
    Cheng, Zhangkai J.
    Bromley, Regina M.
    Oborn, Brad
    Booth, Jeremy T.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (03):
  • [27] A hybrid phase-space and histogram source model for GPU-based Monte Carlo radiotherapy dose calculation
    Townson, Reid W.
    Zavgorodni, Sergei
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24) : 7919 - 7935
  • [28] Monte Carlo proton dose calculations using a radiotherapy specific dual-energy CT scannerfortissue segmentation and range assessment
    Almeida, Isabel P.
    Schyns, Lotte E. J. R.
    Vaniqui, Ana
    van der Heyden, Brent
    Dedes, George
    Resch, Andreas F.
    Kamp, Florian
    Zindler, Jaap D.
    Parodi, Katia
    Landry, Guillaume
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (11)
  • [29] Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source
    Alhakeem, Eyad
    Zavgorodni, Sergei
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01)
  • [30] Monte Carlo calculations of dose rate distributions around the Amersham CDCS-M-type 137Cs source
    Casal, E
    Ballester, F
    Lluch, JL
    Pérez-Calatayud, J
    Lliso, F
    MEDICAL PHYSICS, 2000, 27 (01) : 132 - 140