摘要
Introduction:This is the second of two papers giving an overview of the use of Monte-Carlo techniques for radiotherapy applications. Methods:The first paper gave an introduction and introduced some of the codes that are available to the user wishing to model the different aspects of radiotherapy treatment. It also aims to serve as a useful companion to a curated collection of papers on Monte-Carlo that have been published in this journal. Results and Conclusions:This paper focuses on the application of Monte-Carlo to specific problems in radiotherapy. These include radiotherapy and imaging beam production, brachytherapy, phantom and patient dosimetry, detector modelling and track structure calculations for micro-dosimetry, nano-dosimetry and radiobiology.
引用
收藏
页数:6
相关论文
共 33 条
  • [1] Monte-Carlo techniques for radiotherapy applications I: introduction and overview of the different Monte-Carlo codes
    Fielding, Andrew L.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [2] Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations
    Davidson, Scott E.
    Cui, Jing
    Kry, Stephen
    Deasy, Joseph O.
    Ibbott, Geoffrey S.
    Vicic, Milos
    White, R. Allen
    Followill, David S.
    MEDICAL PHYSICS, 2016, 43 (08) : 4842 - 4853
  • [3] Monte Carlo calculations of radiotherapy dose in "homogeneous" anatomy
    Kairn, Tanya
    Livingstone, Alexander G.
    Crowe, Scott B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 156 - 165
  • [4] Fast on-site Monte Carlo tool for dose calculations in CT applications
    Chen, Wei
    Kolditz, Daniel
    Beister, Marcel
    Bohle, Robert
    Kalender, Willi A.
    MEDICAL PHYSICS, 2012, 39 (06) : 2985 - 2996
  • [5] An analytic linear accelerator source model for GPU-based Monte Carlo dose calculations
    Tian, Zhen
    Li, Yongbao
    Folkerts, Michael
    Shi, Feng
    Jiang, Steve B.
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 7941 - 7967
  • [6] Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy
    Mackeprang, P-H
    Vuong, D.
    Volken, W.
    Henzen, D.
    Schmidhalter, D.
    Malthaner, M.
    Mueller, S.
    Frei, D.
    Stampanoni, M. F. M.
    Dal Pra, A.
    Aebersold, D. M.
    Fix, M. K.
    Manser, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01)
  • [7] Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy
    Bazalova, Magdalena
    Zhou, Hu
    Keall, Paul J.
    Graves, Edward E.
    MEDICAL PHYSICS, 2009, 36 (11) : 4991 - 4999
  • [8] From radiobiology to radiotherapy: dose homogeneity in cells after alpha irradiation in measurements and Monte Carlo simulations
    Filipek, Mateusz
    Pszczolkowska-Kepa, Beata
    Kocinski, Bartlomiej
    Senkowska, Marta
    Szeflinski, Zygmunt
    Brzozowska, Beata
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (02): : 79 - 89
  • [9] Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy
    Fix, MK
    Keller, H
    Rüegsegger, P
    Born, EJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2739 - 2747
  • [10] NanoDotTM OSLDs in verifying radiotherapy dose calculations in the presence of metal implants: A Monte Carlo assisted research
    Ispir, Emine Burcin
    Sarigul, Neslihan
    Yegingil, Zehra
    RADIATION PHYSICS AND CHEMISTRY, 2021, 187