Robust Heart Rate Measurement by Adaptive ROI Selection for Head-Rotation Conditions

被引:4
作者
Fan, Xuanhe [1 ,2 ]
Liu, Fangwu [3 ]
Huang, Zhijie [1 ,2 ]
Xue, Wei [1 ,2 ]
Gao, Tong [1 ,2 ]
Fu, Jia [1 ,2 ]
Zhang, Jingjing [1 ,2 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Peoples R China
[2] Minist Educ, Hubei Key Lab Adv Control & Intelligent Automat Co, Wuhan 430074, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Tech Phys, Shanghai 200083, Peoples R China
关键词
Signal to noise ratio; Head; Reflection; Heart rate; Heart rate measurement; Lighting; Faces; Adaptive selection; head rotation; heart rate (HR) measurement; illuminance; imaging photoplethysmography; reflection angle; region of interest (ROI); NONCONTACT; PHOTOPLETHYSMOGRAPHY; TIME;
D O I
10.1109/TIM.2023.3323992
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Region-of-interest (ROI) selection is a key process for the remote heart rate (HR) measurement approach. Previous studies have shown that the selected ROI could easily be lost under head-rotation circumstances and does not perform well under drastic changes in illumination. To solve the problems, this work proposed a novel adaptive ROI selection method. First, we collected a dataset for modeling the signal-to-noise ratio (SNR) evaluated by illumination and reflection angle. Second, we established an SNR-estimated model by studying the mathematical correlations between light intensity, reflected angle, and the SNR of the regions on the face. Then, we proposed a robust ROI selection method based on the SNR-estimated model for adaptive ROI selection. Finally, the ROI change denoising method is proposed to remove the ROI change noise for synthesizing the imaging photoplethysmography (iPPG) signal and calculating the HR. Performances of the proposed method were tested on three datasets, including our collected dataset and two public datasets. The experimental results show that on the MR-NIRP CAR dataset, the percentage of the time that the HR error is less than 6 bpm (PET6) value is higher than 7.3% and 4.6%, respectively, compared with the state-of-the-art (SOTA) methods. The SNR, standard deviation error (SD), mean absolute error (MAE), and root mean squared error (RMSE) metrics are also improved on the Head-rotation and PURE datasets. Therefore, our method is robust and can potentially be applied in various scenarios.
引用
收藏
页数:12
相关论文
共 36 条
[1]   Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study [J].
Aarts, Lonneke A. M. ;
Jeanne, Vincent ;
Cleary, John P. ;
Lieber, C. ;
Nelson, J. Stuart ;
Oetomo, Sidarto Bambang ;
Verkruysse, Wim .
EARLY HUMAN DEVELOPMENT, 2013, 89 (12) :943-948
[2]   The Leading Causes of Death in the US for 2020 [J].
Ahmad, Farida B. ;
Anderson, Robert N. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (18) :1829-1830
[3]  
Das Mousumi, 2022, 2022 International Conference on Wireless Communications Signal Processing and Networking (WiSPNET), P115, DOI 10.1109/WiSPNET54241.2022.9767186
[4]   Robust Pulse Rate From Chrominance-Based rPPG [J].
de Haan, Gerard ;
Jeanne, Vincent .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) :2878-2886
[5]   Optimizing Remote Photoplethysmography Using Adaptive Skin Segmentation for Real-Time Heart Rate Monitoring [J].
Fouad, R. M. ;
Omer, Osama A. ;
Aly, Moustafa H. .
IEEE ACCESS, 2019, 7 :76513-76528
[6]   Automated Non-Contact Respiratory Rate Monitoring of Neonates Based on Synchronous Evaluation of a 3D Time-of-Flight Camera and a Microwave Interferometric Radar Sensor [J].
Gleichauf, Johanna ;
Herrmann, Sven ;
Hennemann, Lukas ;
Krauss, Hannes ;
Nitschke, Janina ;
Renner, Philipp ;
Niebler, Christine ;
Koelpin, Alexander .
SENSORS, 2021, 21 (09)
[7]   Effects of illuminance intensity on the green channel of remote photoplethysmography (rPPG) signals [J].
Guler, Saygun ;
Ozturk, Ozberk ;
Golparvar, Ata ;
Dogan, Huseyin ;
Yapici, Murat Kaya .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (04) :1317-1323
[8]   Hyperspectral imaging enabled by an unmodified smartphone for analyzing skin morphological features and monitoring hemodynamics [J].
He, Qinghua ;
Wang, Ruikang .
BIOMEDICAL OPTICS EXPRESS, 2020, 11 (02) :895-910
[9]   A novel approach to create synthetic biomedical signals using BiRNN [J].
Hernandez-Matamoros, Andres ;
Fujita, Hamido ;
Perez-Meana, Hector .
INFORMATION SCIENCES, 2020, 541 :218-241
[10]   Non-contact monitoring of respiration in the neonatal intensive care unit [J].
Jorge, Joao ;
Villarroel, Mauricio ;
Chaichulee, Sitthichok ;
Guazzi, Alessandro ;
Davis, Sara ;
Green, Gabrielle ;
McCormick, Kenny ;
Tarassenko, Lionel .
2017 12TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION (FG 2017), 2017, :286-293