Low-Cost Technologies Used in Corrosion Monitoring

被引:36
作者
Komary, Mahyad [1 ]
Komarizadehasl, Seyedmilad [1 ]
Tosic, Nikola [1 ]
Segura, I. [1 ]
Lozano-Galant, Jose Antonio [2 ]
Turmo, Jose [1 ]
机构
[1] Univ Politecn Cataluna, Dept Civil & Environm Engn, BarcelonaTech, C Jordi Girona 1-3, Barcelona 08034, Spain
[2] Univ Castilla La Mancha, Dept Civil Engn, Ave Camilo Jose Cela S-N, Ciudad Real 13071, Spain
关键词
corrosion monitoring; electrochemical sensors; data acquisition; data analysis; physical methods; structural health monitoring; low-cost sensors; atmospheric corrosion; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ATMOSPHERIC CORROSION; WIRELESS; STEEL; SENSOR; CONCRETE; NOISE; SYSTEM; FIELD; RECOGNITION;
D O I
10.3390/s23031309
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Globally, corrosion is the costliest cause of the deterioration of metallic and concrete structures, leading to significant financial losses and unexpected loss of life. Therefore, corrosion monitoring is vital to the assessment of structures' residual performance and for the identification of pathologies in early stages for the predictive maintenance of facilities. However, the high price tag on available corrosion monitoring systems leads to their exclusive use for structural health monitoring applications, especially for atmospheric corrosion detection in civil structures. In this paper a systematic literature review is provided on the state-of-the-art electrochemical methods and physical methods used so far for corrosion monitoring compatible with low-cost sensors and data acquisition devices for metallic and concrete structures. In addition, special attention is paid to the use of these devices for corrosion monitoring and detection for in situ applications in different industries. This analysis demonstrates the possible applications of low-cost sensors in the corrosion monitoring sector. In addition, this study provides scholars with preferred techniques and the most common microcontrollers, such as Arduino, to overcome the corrosion monitoring difficulties in the construction industry.
引用
收藏
页数:28
相关论文
共 154 条
[41]   Optical fiber-based chemical sensors for detection of corrosion precursors and by-products [J].
Elster, J ;
Greene, J ;
Jones, M ;
Bailey, T ;
Lenahan, S ;
Velander, W ;
VanTassell, R ;
Hodges, W ;
Perez, I .
CHEMICAL, BIOCHEMICAL, AND ENVIRONMENTAL FIBER SENSORS X, 1999, 3540 :251-257
[42]   Effect of Ti and Al on the pulverization resistance of MgNi-based metal hydride electrodes evaluated by acoustic emission [J].
Etiemble, A. ;
Idrissi, H. ;
Roue, L. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (02) :1136-1144
[43]   Techniques of corrosion monitoring of steel rebar in reinforced concrete structures: A review [J].
Fan, Liang ;
Shi, Xianming .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2022, 21 (04) :1879-1905
[44]  
Friedersdorf F.J., 2013, P CORROSION 2013
[45]   Monitoring active corrosion of metals in natural environments with magnetometry [J].
Gallo, Gonzalo E. ;
Popovics, John S. .
CORROSION SCIENCE, 2012, 63 :1-4
[46]   A simple Arduino-based EIS system for in situ corrosion monitoring of metallic works of art [J].
Grassini, S. ;
Corbellini, S. ;
Parvis, M. ;
Angelini, E. ;
Zucchi, F. .
MEASUREMENT, 2018, 114 :508-514
[47]  
Guan S., 2014, EC REFORM INTERNATIO, V2, P761
[48]  
Halabe Udaya B., 2016, Geotechnical and Structural Engineering Congress 2016, P1016
[49]   Health monitoring of a complex structure using a sparse array of modally selective transducers [J].
Harper, M. F. ;
Thompson, M. .
NONDESTRUCTIVE TESTING AND EVALUATION, 2005, 20 (03) :159-173
[50]   Development of a Microelectromechanical System (MEMS)-Based Multisensor Platform for Environmental Monitoring [J].
Hautefeuille, Mathieu ;
O'Flynn, Brendan ;
Peters, Frank H. ;
O'Mahony, Conor .