Association of ocular surface and meibomian gland alterations with silicone hydrogel contact lens wear

被引:3
|
作者
Colak, Dilan [1 ,4 ]
Kocabeyoglu, Sibel [2 ]
Karakaya, Jale [3 ]
Irkec, Murat [4 ]
机构
[1] Medicana Atakoy Hosp, Istanbul, Turkiye
[2] Hacettepe Univ, Sch Med, Dept Ophthalmol, Ankara, Turkiye
[3] Hacettepe Univ, Sch Med, Dept Biostat, Ankara, Turkiye
[4] Medicana Atakoy Hosp, Atakoy 2-5-6 Kisim Mahallesi,Rauf Orbay Caddesi 1, Istanbul, Turkiye
来源
CONTACT LENS & ANTERIOR EYE | 2024年 / 47卷 / 01期
关键词
Silicone hydrogel contact lens; Meibomian gland dysfunction; Meibography; Dry eye; In vivo confocal microscopy; Ocular discomfort; TFOS INTERNATIONAL WORKSHOP; DRY EYE DISEASE; TEAR FILM; CORNEAL SENSITIVITY; IN-VIVO; PREVALENCE; DYSFUNCTION; IMPACT;
D O I
10.1016/j.clae.2023.102093
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate silicone hydrogel contact lens (SH-CL) effects on the meibomian glands, corneal structure, and ocular surface parameters. Methods: Fifty SH-CL wearers for at least 6 months, and 50 sex and age-matched control subjects were recruited for this cross-sectional study. Visual display terminal (VDT) work and CL wear duration were questioned, ocular surface and tear functions were evaluated using OSDI questionnaire, tear break-up time (TBUT), corneal fluorescein staining, and Schirmer test. Corneal sensitivity was measured with Cochet-Bonnet aesthesiometry. Meibography and in vivo confocal microscopy (IVCM) were performed to evaluate meibomian glands and corneal structure. Intergroup comparisons were made using the Chi-square test, Wilcoxon test, or Kruskal-Wallis test. Results: In the CL group, TBUT was shorter (P = 0.01), corneal fluorescein staining (P = 0.04), OSDI scores (P < 0.001), and meiboscores (P < 0.001) were higher than the control group. The biomicroscopic evaluation revealed meibomian gland dysfunction (MGD) in 34 % of the CL group and 20 % of the control group, which was not statistically significant (P > 0.05). IVCM showed that endothelial cell density was lower (P = 0.01) and polymegethism was higher (P < 0.001) in the CL group. Subbasal nerve density and corneal sensitivity measurements were similar in the two groups (P > 0.05). The longer VDT work duration was associated with increased CFS in the CL group (P = 0.05). Conclusion: The results showed that SH-CL wear increased dry eye symptoms and ocular discomfort, especially in longer VDT work duration. Meibography revealed significantly worse results in SH-CL wearers. SH-CL-related ocular discomfort seems to be more associated with MGD rather than neurosensorial alterations.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] The role of sphingolipids in meibomian gland dysfunction and ocular surface inflammation
    Paranjpe, Vikram
    Galor, Anat
    Grambergs, Richard
    Mandal, Nawajes
    OCULAR SURFACE, 2022, 26 : 100 - 110
  • [32] The influence of meibomian gland loss on ocular surface clinical parameters
    Rico-del-Viejo, Laura
    Manuel Benitez-del-Castillo, Jose
    Javier Gomez-Sanz, Fernando
    Garcia-Montero, Maria
    Llorens-Quintana, Clara
    Madrid-Costa, David
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (05): : 562 - 568
  • [33] Bacteriological profile of ocular surface flora in meibomian gland dysfunction
    Zhang, Shao Dan
    He, Jing Na
    Niu, Tong Tong
    Chan, Chiu Yeung
    Ren, Chun Yang
    Liu, Shan Shan
    Qu, Yang
    Chong, Kam Lung
    Wang, Hai Lin
    Tao, Jun
    Pang, Chi Pui
    OCULAR SURFACE, 2017, 15 (02): : 242 - 247
  • [34] Intolerant contact lens wearers exhibit ocular surface impairment despite 3 months wear discontinuation
    Giannaccare, Giuseppe
    Blalock, William
    Fresina, Michela
    Vagge, Aldo
    Versura, Piera
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (09) : 1825 - 1831
  • [35] Contact lens-related dry eye and ocular surface changes with mapping technique in long-term soft silicone hydrogel contact lens wearers
    Sengor, Tomris
    Kurna, Sevda Aydin
    Ozbay, Nurver
    Ertek, Semahat
    Aki, Suat
    Altun, Ahmet
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 : S17 - S23
  • [36] Wear Experience of a Water Surface Daily Disposable Contact Lens in Existing Silicone Hydrogel Planned Replacement Lens Wearers
    Rutschilling, Ryan
    Fogt, Jennifer Swingle
    CLINICAL OPTOMETRY, 2022, 14 : 27 - 34
  • [37] Comparison of Morphological and Functional Meibomian Gland Characteristics Between Daily Contact Lens Wearers and Nonwearers
    Machalinska, Anna
    Zakrzewska, Aleksandra
    Adamek, Bogdan
    Safranow, Krzysztof
    Wiszniewska, Barbara
    Parafiniuk, Miroslaw
    Machalinski, Boguslaw
    CORNEA, 2015, 34 (09) : 1098 - 1104
  • [38] Is complete androgen insensitivity syndrome associated with alterations in the meibomian gland and ocular surface?
    Cermak, JM
    Krenzer, KL
    Sullivan, RM
    Dana, MR
    Sullivan, DA
    CORNEA, 2003, 22 (06) : 516 - 521
  • [39] A novel noninvasive ocular surface analyzer for the assessment of dry eye with Meibomian gland dysfunction
    Qi, Yuanyuan
    Zhang, Chen
    Zhao, Shaozhen
    Huang, Yue
    Yang, Ruibo
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 13 (06) : 2983 - 2988
  • [40] Meibomian gland dysfunction (MGD), as diagnosed by non-contact infrared Meibography, in dogs with ocular surface disorders (OSD): a retrospective study
    Vinas, Marta
    Maggio, Federica
    D'Anna, Nunzio
    Rabozzi, Roberto
    Peruccio, Claudio
    BMC VETERINARY RESEARCH, 2019, 15 (01)