Association of ocular surface and meibomian gland alterations with silicone hydrogel contact lens wear

被引:3
|
作者
Colak, Dilan [1 ,4 ]
Kocabeyoglu, Sibel [2 ]
Karakaya, Jale [3 ]
Irkec, Murat [4 ]
机构
[1] Medicana Atakoy Hosp, Istanbul, Turkiye
[2] Hacettepe Univ, Sch Med, Dept Ophthalmol, Ankara, Turkiye
[3] Hacettepe Univ, Sch Med, Dept Biostat, Ankara, Turkiye
[4] Medicana Atakoy Hosp, Atakoy 2-5-6 Kisim Mahallesi,Rauf Orbay Caddesi 1, Istanbul, Turkiye
来源
CONTACT LENS & ANTERIOR EYE | 2024年 / 47卷 / 01期
关键词
Silicone hydrogel contact lens; Meibomian gland dysfunction; Meibography; Dry eye; In vivo confocal microscopy; Ocular discomfort; TFOS INTERNATIONAL WORKSHOP; DRY EYE DISEASE; TEAR FILM; CORNEAL SENSITIVITY; IN-VIVO; PREVALENCE; DYSFUNCTION; IMPACT;
D O I
10.1016/j.clae.2023.102093
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate silicone hydrogel contact lens (SH-CL) effects on the meibomian glands, corneal structure, and ocular surface parameters. Methods: Fifty SH-CL wearers for at least 6 months, and 50 sex and age-matched control subjects were recruited for this cross-sectional study. Visual display terminal (VDT) work and CL wear duration were questioned, ocular surface and tear functions were evaluated using OSDI questionnaire, tear break-up time (TBUT), corneal fluorescein staining, and Schirmer test. Corneal sensitivity was measured with Cochet-Bonnet aesthesiometry. Meibography and in vivo confocal microscopy (IVCM) were performed to evaluate meibomian glands and corneal structure. Intergroup comparisons were made using the Chi-square test, Wilcoxon test, or Kruskal-Wallis test. Results: In the CL group, TBUT was shorter (P = 0.01), corneal fluorescein staining (P = 0.04), OSDI scores (P < 0.001), and meiboscores (P < 0.001) were higher than the control group. The biomicroscopic evaluation revealed meibomian gland dysfunction (MGD) in 34 % of the CL group and 20 % of the control group, which was not statistically significant (P > 0.05). IVCM showed that endothelial cell density was lower (P = 0.01) and polymegethism was higher (P < 0.001) in the CL group. Subbasal nerve density and corneal sensitivity measurements were similar in the two groups (P > 0.05). The longer VDT work duration was associated with increased CFS in the CL group (P = 0.05). Conclusion: The results showed that SH-CL wear increased dry eye symptoms and ocular discomfort, especially in longer VDT work duration. Meibography revealed significantly worse results in SH-CL wearers. SH-CL-related ocular discomfort seems to be more associated with MGD rather than neurosensorial alterations.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The Role of Soft Contact Lens Wear on Meibomian Gland Morphology and Function
    Pucker, Andrew D.
    Jones-Jordan, Lisa A.
    Marx, Sebastian
    Powell, Daniel R.
    Kwan, Justin T.
    Sickenberger, Wolfgang
    Jones, Lyndon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (04): : 276 - 277
  • [22] Associations with Meibomian Gland Atrophy in Daily Contact Lens Wearers
    Pucker, Andrew D.
    Jones-Jordan, Lisa A.
    Li, Wing
    Kwan, Justin T.
    Lin, Meng C.
    Sickenberger, Wolfgang
    Marx, Sebastian
    Srinivasan, Sruthi
    Jones, Lyndon W.
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (09) : E206 - E213
  • [23] CONTACT-LENS WEAR, USE OF EYE COSMETICS, AND MEIBOMIAN GLAND DYSFUNCTION
    MARREN, SE
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (01) : 60 - 62
  • [24] Ocular surface microbiome in meibomian gland dysfunction
    Watters, Grant A.
    Turnbull, Philip R.
    Swift, Simon
    Petty, Alex
    Craig, Jennifer P.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (02): : 105 - 111
  • [25] A silicone hydrogel contact lens after 7 years of continuous wear
    Yesilirmak, Nilufer
    Altmors, Dilek D.
    CONTACT LENS & ANTERIOR EYE, 2013, 36 (04): : 204 - 206
  • [26] Changes in ocular physiology, tear film characteristics, and symptomatology with 18 months silicone hydrogel contact lens wear
    Santodomingo-Rubido, J
    Wolffsohn, JS
    Gilmartin, B
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (02) : 73 - 81
  • [27] Ocular Surface Workup With Automated Noninvasive Measurements for the Diagnosis of Meibomian Gland Dysfunction
    Giannaccare, Giuseppe
    Vigo, Luca
    Pellegrini, Marco
    Sebastiani, Stefano
    Carones, Francesco
    CORNEA, 2018, 37 (06) : 740 - 745
  • [28] Impact of duration of contact lens wear on the structure and function of the meibomian glands
    Alghamdi, Waleed M.
    Markoulli, Maria
    Holden, Brien A.
    Papas, Eric B.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (02) : 120 - 131
  • [29] The association between demodex infestation and ocular surface manifestations in meibomian gland dysfunction
    Zhang, Xiao-Bo
    Ding, Ying-Hui
    He, Wei
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (04) : 589 - 592
  • [30] Ocular surface inflammation impairs structure and function of meibomian gland
    Mizoguchi, Shin
    Iwanishi, Hiroki
    Arita, Reiko
    Shirai, Kumi
    Sumioka, Takayoshi
    Kokado, Masahide
    Jester, James V.
    Saika, Shizuya
    EXPERIMENTAL EYE RESEARCH, 2017, 163 : 78 - 84