Association of ocular surface and meibomian gland alterations with silicone hydrogel contact lens wear

被引:3
|
作者
Colak, Dilan [1 ,4 ]
Kocabeyoglu, Sibel [2 ]
Karakaya, Jale [3 ]
Irkec, Murat [4 ]
机构
[1] Medicana Atakoy Hosp, Istanbul, Turkiye
[2] Hacettepe Univ, Sch Med, Dept Ophthalmol, Ankara, Turkiye
[3] Hacettepe Univ, Sch Med, Dept Biostat, Ankara, Turkiye
[4] Medicana Atakoy Hosp, Atakoy 2-5-6 Kisim Mahallesi,Rauf Orbay Caddesi 1, Istanbul, Turkiye
来源
CONTACT LENS & ANTERIOR EYE | 2024年 / 47卷 / 01期
关键词
Silicone hydrogel contact lens; Meibomian gland dysfunction; Meibography; Dry eye; In vivo confocal microscopy; Ocular discomfort; TFOS INTERNATIONAL WORKSHOP; DRY EYE DISEASE; TEAR FILM; CORNEAL SENSITIVITY; IN-VIVO; PREVALENCE; DYSFUNCTION; IMPACT;
D O I
10.1016/j.clae.2023.102093
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate silicone hydrogel contact lens (SH-CL) effects on the meibomian glands, corneal structure, and ocular surface parameters. Methods: Fifty SH-CL wearers for at least 6 months, and 50 sex and age-matched control subjects were recruited for this cross-sectional study. Visual display terminal (VDT) work and CL wear duration were questioned, ocular surface and tear functions were evaluated using OSDI questionnaire, tear break-up time (TBUT), corneal fluorescein staining, and Schirmer test. Corneal sensitivity was measured with Cochet-Bonnet aesthesiometry. Meibography and in vivo confocal microscopy (IVCM) were performed to evaluate meibomian glands and corneal structure. Intergroup comparisons were made using the Chi-square test, Wilcoxon test, or Kruskal-Wallis test. Results: In the CL group, TBUT was shorter (P = 0.01), corneal fluorescein staining (P = 0.04), OSDI scores (P < 0.001), and meiboscores (P < 0.001) were higher than the control group. The biomicroscopic evaluation revealed meibomian gland dysfunction (MGD) in 34 % of the CL group and 20 % of the control group, which was not statistically significant (P > 0.05). IVCM showed that endothelial cell density was lower (P = 0.01) and polymegethism was higher (P < 0.001) in the CL group. Subbasal nerve density and corneal sensitivity measurements were similar in the two groups (P > 0.05). The longer VDT work duration was associated with increased CFS in the CL group (P = 0.05). Conclusion: The results showed that SH-CL wear increased dry eye symptoms and ocular discomfort, especially in longer VDT work duration. Meibography revealed significantly worse results in SH-CL wearers. SH-CL-related ocular discomfort seems to be more associated with MGD rather than neurosensorial alterations.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The Role of Soft Contact Lens Wear on Meibomian Gland Morphology and Function
    Ucakhan, Omur
    Arslanturk-Eren, Mehtap
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (05): : 292 - 300
  • [2] Sensory Adaptation to Silicone Hydrogel Contact Lens Wear Is Not Associated With Alterations in the Corneal Subbasal Nerve Plexus
    Kocabeyoglu, Sibel
    Colak, Dilan
    Mocan, Mehmet C.
    Irkec, Murat
    CORNEA, 2019, 38 (09) : 1142 - 1146
  • [3] Topical review of the relationship between contact lens wear and meibomian gland dysfunction
    Ifrah, Reut
    Quevedo, Lluisa
    Gantz, Liat
    JOURNAL OF OPTOMETRY, 2023, 16 (01) : 12 - 19
  • [4] Compatibility of phospholipid liposomal spray with silicone hydrogel contact lens wear
    Wang, Michael T. M.
    Ganesalingam, Kalaivarny
    Loh, Chee Seang
    Alberquerque, Trisha
    Al-Kanani, Suhaila
    Misra, Stuti L.
    Craig, Jennifer P.
    CONTACT LENS & ANTERIOR EYE, 2017, 40 (01): : 53 - 58
  • [5] The Effects of Soft Contact Lens Wear on The Tear Film and Meibomian Gland Drop-Out and Visibility
    Vicente Garcia-Marques, Jose
    Talens-Estarelles, Cristian
    Garcia-Lazaro, Santiago
    Cervino, Alejandro
    LIFE-BASEL, 2022, 12 (08):
  • [6] Effects of Silicone Hydrogel Contact Lens Wear on Ocular Surface Sensitivity to Tactile, Pneumatic Mechanical, and Chemical Stimulation
    Situ, Ping
    Simpson, Trefford L.
    Jones, Lyndon W.
    Fonn, Desmond
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6111 - 6117
  • [7] A review of meibomian gland structure, function, and contact lens wear
    Rueff, Erin M.
    Tichenor, Anna A.
    Ngo, William
    Pucker, Andrew D.
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (05):
  • [8] The effects of 2 week senofilcon-A silicone hydrogel contact lens daily wear on tear functions and ocular surface health status
    Dogru, Murat
    Ward, Samantha K.
    Wakamatsu, Tais
    Ibrahim, Osama
    Schnider, Cristina
    Kojima, Takashi
    Matsumoto, Yukihiro
    Ogawa, Junko
    Shimazaki, Jun
    Tsubota, Kazuo
    CONTACT LENS & ANTERIOR EYE, 2011, 34 (02): : 77 - 82
  • [9] Association Between Meibomian Gland Testing and Ocular Surface Sensitivity
    Cox, Stephanie M.
    Nichols, Jason J.
    CORNEA, 2015, 34 (10) : 1187 - 1192
  • [10] Contact Lens Wear Is Associated with Decrease of Meibomian Glands
    Arita, Reiko
    Itoh, Kouzo
    Inoue, Kenji
    Kuchiba, Aya
    Yamaguchi, Takuhiro
    Amano, Shiro
    OPHTHALMOLOGY, 2009, 116 (03) : 379 - 384