Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study

被引:8
作者
Muders, Thomas [1 ]
Hentze, Benjamin [1 ,2 ]
Leonhardt, Steffen [2 ]
Putensen, Christian [1 ]
机构
[1] Univ Hosp Bonn, Dept Anesthesiol & Intens Care Med, D-53127 Bonn, Germany
[2] Rhein Westfal TH Aachen, Chair Med Informat Technol, D-52074 Aachen, Germany
关键词
individualized therapy; electrical impedance tomography; bedside monitoring; bedside visualization; pulmonary perfusion; contrast agent; functional imaging; IMPACT; INJURY; MEDIA; MODEL;
D O I
10.3390/jcm12082751
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Monitoring regional blood flow distribution in the lungs appears to be useful for individually optimizing ventilation therapy. Electrical impedance tomography (EIT) can be used at the bedside for indicator-based regional lung perfusion measurement. Hypertonic saline is widely used as a contrast agent but could be problematic for clinical use due to potential side effects. In five ventilated healthy pigs, we investigated the suitability of five different injectable and clinically approved solutions as contrast agents for EIT-based lung perfusion measurement. Signal extraction success rate, signal strength, and image quality were analyzed after repeated 10 mL bolus injections during temporary apnea. The best results were obtained using NaCl 5.85% and sodium-bicarbonate 8.4% with optimal success rates (100%, each), the highest signal strengths (100 +/- 25% and 64 +/- 17%), and image qualities (r = 0.98 +/- 0.02 and 0.95 +/- 0.07). Iomeprol 400 mg/mL (non-ionic iodinated X-ray contrast medium) and Glucose 5% (non-ionic glucose solution) resulted in mostly well usable signals with above average success rates (87% and 89%), acceptable signal strength (32 +/- 8% and 16 + 3%), and sufficient image qualities (r = 0.80 +/- 0.19 and 0.72 +/- 0.21). Isotonic balanced crystalloid solution failed due to a poor success rate (42%), low signal strength (10 +/- 4%), and image quality (r = 0.43 +/- 0.28). While Iomeprol might enable simultaneous EIT and X-ray measurements, glucose might help to avoid sodium and chloride overload. Further research should address optimal doses to balance reliability and potential side effects.
引用
收藏
页数:12
相关论文
共 49 条
  • [21] Body and head position effects on regional lung ventilation in infants: an electrical impedance tomography study
    Sina Heinrich
    Holger Schiffmann
    Alexander Frerichs
    Adelbert Klockgether-Radke
    Inéz Frerichs
    Intensive Care Medicine, 2006, 32
  • [22] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Ulrich Krause
    Kristin Becker
    Günter Hahn
    Jörg Dittmar
    Wolfgang Ruschewski
    Thomas Paul
    Pediatric Cardiology, 2014, 35 : 990 - 997
  • [23] Monitoring of Regional Lung Ventilation Using Electrical Impedance Tomography After Cardiac Surgery in Infants and Children
    Krause, Ulrich
    Becker, Kristin
    Hahn, Guenter
    Dittmar, Joerg
    Ruschewski, Wolfgang
    Paul, Thomas
    PEDIATRIC CARDIOLOGY, 2014, 35 (06) : 990 - 997
  • [24] Using electrical impedance tomography to characterize lung impairment of children with primary ciliary dyskinesia: A pilot cross-sectional study
    Pensabene, Mariacarola
    Gambazza, Simone
    Carta, Federica
    Rocchi, Alessia
    Lelii, Mara
    Madini, Barbara
    Hassan, Vittoria
    Piotto, Marta
    Patria, Maria Francesca
    PEDIATRIC PULMONOLOGY, 2023, 58 (04) : 1051 - 1058
  • [25] Evaluation of lung ventilation distribution using electrical impedance tomography in standing sedated horses with capnoperitoneum
    Beazley, Shannon G.
    Focken, Alex
    Fernandez-Parra, Rocio
    Thomas, Keri L.
    Adler, Andy
    Duke-Novakovski, Tanya
    VETERINARY ANAESTHESIA AND ANALGESIA, 2022, 49 (04) : 382 - 389
  • [26] Influence of different electrode belt positions on electrical impedance tomography imaging of regional ventilation: a prospective observational study
    Jan Karsten
    Thomas Stueber
    Nicolas Voigt
    Eckhard Teschner
    Hermann Heinze
    Critical Care, 20
  • [27] Conductivity Distribution Measurement at Different Low Frequencies Using a Modular 64 Electrode Electrical Impedance Tomography System
    Dimas, Christos
    Sotiriadis, Paul P.
    2017 4TH PANHELLENIC CONFERENCE ON ELECTRONICS AND TELECOMMUNICATIONS (PACET), 2017, : 133 - 136
  • [28] Evaluation of Electrical Impedance Tomography for a Measurement of Tidal Volume in High-frequency Ventilation of the Pig - Case Study
    Rozanek, Martin
    Kudrna, Petr
    Rafl, Jakub
    Ort, Vaclav
    Kordik, Marek
    Roubik, Karel
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [29] Experimental Study on Early Detection of Acute Cerebral Ischemic Stroke Using Electrical Impedance Tomography Method
    Shi, Xuetao
    You, Fusheng
    Xu, Canhua
    Wang, Liang
    Fu, Feng
    Liu, Ruigang
    Dong, Xiuzhen
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 510 - 513
  • [30] Effects of different VV ECMO blood flow rates on lung perfusion assessment by hypertonic saline bolus-based electrical impedance tomography
    Zhang, Hongling
    Wu, Yongran
    Gao, Xuehui
    Peng, Chengchao
    Li, Ruirui
    Wang, Azhen
    Zhang, Jiancheng
    Yuan, Shiying
    Yang, Le
    Zou, Xiaojing
    Shang, You
    CRITICAL CARE, 2024, 28 (01)