Determination of absolute Np L x-ray emission intensities from 241Am decay using a metallic magnetic calorimeter

被引:2
|
作者
Rodrigues, Matias [1 ]
Loidl, Martin [1 ]
Pierre, Sylvie [1 ]
机构
[1] Univ Paris Saclay, CEA, List, Lab Natl Henri Becquerel LNE LNHB, F-91120 Palaiseau, France
关键词
photon emission intensity; radionuclide metrology; metallic magnetic calorimeter; ericium-241; decay data; HPGE DETECTOR; FOCK VALUES; EFFICIENCY; FLUORESCENCE; ATTENUATION; ALPHA; UNCERTAINTY; TRANSPORT;
D O I
10.1088/1681-7575/acb99f
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Photon emission intensities of radionuclides, i.e. the number of emitted photons per decay, are the single most important decay data when the photon spectrometry technique is employed in ionizing radiation metrology. However, their precise measurement is problematic because they are usually determined by photon spectrometry with spectrometers having a detection efficiency calibrated with x-ray and gamma-ray emission intensities from other radionuclides. Therefore, these intensities are ultimately interdependent and correlated to some extent. A novel method was applied to determine the photon intensities of alpha-emitting radionuclides by measuring the ratio between the rate of photons in the full energy peaks and the rate of detected alpha-particles with the same detection set-up. Thus, there is no need to calibrate the detection efficiency and to standardize calibration sources by primary methods. The main condition to reach low uncertainties is to have a spectrometer with an intrinsic detection efficiency close to unity for the measured photons and alpha-particles. This condition was fulfilled by a metallic magnetic calorimeter (MMC) with an intrinsic efficiency of around 99% between 5 keV and 25 keV. In addition, the MMC provides an ultra-high energy resolution of 28 eV (full width at half maximum), facilitating the processing of the spectrum. The method was applied to determine L x-ray emission intensities from the decay of Am-241(alpha) -> Np-237 emitted between 11.9 keV and 22.4 keV. A total L x-ray emission intensity of 37.90 (12) per 100 disintegrations was obtained; the value agrees well with previous measurements and has a lower uncertainty. The uncertainties of the L x-ray groups L alpha, L eta beta and L gamma were improved by a factor of two. Moreover, due to the high-energy resolution of 28 eV, a detailed set of 33 L x-ray emission intensities are provided.
引用
收藏
页数:18
相关论文
共 37 条
  • [1] Measurement of 241Am L X-ray emission probabilities
    Lepy, M. C.
    Plagnard, J.
    Ferreux, L.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 715 - 721
  • [2] Determination of L-X-ray line emission intensities in the decay of Cm-244 with a metallic magnetic calorimeter
    Mariam, Riham
    Rodrigues, Matias
    Loidl, Martin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [3] Determination of 51Cr and 241Am X-ray and gamma-ray emission probabilities per decay
    Moreira, Denise S.
    Koskinas, Marina F.
    Yamazaki, Ione M.
    Dias, Mauro S.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 596 - 599
  • [4] Measurements of M and L X-ray energies and relative intensities emanating from 241Am source
    Verma, H. R.
    APPLIED RADIATION AND ISOTOPES, 2017, 122 : 41 - 46
  • [5] Performances of a metallic magnetic calorimeter for the measurement of hard X-ray emission intensities
    Rodrigues, M.
    Loidl, M.
    Le-Bret, C.
    X-RAY SPECTROMETRY, 2012, 41 (02) : 64 - 68
  • [6] Theoretical L X-ray emission probabilities in the decay of Am-241
    Johnston, PN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (01): : 107 - 112
  • [7] Determination of L-X ray absolute emission intensities of 238Pu, 244Cm, 237Np and 233Pa radionuclides using a metallic magnetic calorimeter
    Mariam, Riham
    Rodrigues, Matias
    Loidl, Martin
    Pierre, Sylvie
    Lourenco, Valerie
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 187
  • [8] Measurement of absolute K X-ray emission intensities in the decay of 103mRh
    Riffaud, J.
    Cassette, P.
    Lacour, D.
    Lourenco, V.
    Tartes, I.
    Kellett, M. A.
    Corbel, M.
    Lepy, M. -C.
    Domergue, C.
    Destouches, C.
    Carcreff, H.
    Vigneau, O.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 399 - 405
  • [9] The feasibility of in vivo detection of lanthanum using a 241Am K x-ray fluorescence system
    Joanna Nguyen
    Keldani, Zaid
    Da Silva, Eric
    Pejovic-Milic, Ana
    Grafe, James L.
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (09) : 1766 - 1775
  • [10] M-SHELL X-RAY FLUORESCENCE AND COSTER-KRONIG YIELDS OF 93 NP FROM AM241 DECAY
    KARTTUNE.E
    FREUND, HU
    FINK, RW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (06): : 796 - &