Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis

被引:7
|
作者
Li, Wenhao [1 ,2 ]
Zhao, He [2 ]
Li, Chuanhong [1 ,2 ]
Liu, Tao [1 ,2 ]
Guan, Jianbin [1 ,2 ]
Yang, Yongdong [1 ,2 ]
Yu, Xing [2 ]
机构
[1] Beijing Univ Chinese Med, Beijing 100700, Peoples R China
[2] Beijing Univ Chinese Med, Dongzhimen Hosp, Beijing 100700, Peoples R China
关键词
Lumbar fusion surgery; Meta-analysis; PEEK rod; Titanium rod; SPINE; IMPLANT;
D O I
10.1186/s13018-023-03817-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Rigid fixation, represented by titanium rods, is a widely used fixation technique for lumbar fusion. However, this technique carries the risk of degeneration of adjacent segments. In recent years, the semi-rigid fixation technique represented by PEEK rods has gradually matured, and its effectiveness has been verified by numerous studies. The aim of this study was to systematically evaluate the effectiveness of these two fixation modalities in posterior lumbar fusion surgery. Methods Studies meeting the inclusion criteria were searched in PubMed, Cochrane Library, ScienceDirect, Embase, CNKI, and Wanfang databases. After data extraction and quality assessment of included studies, meta-analysis was performed using STATA 15.1 software. The protocol for this systematic review was registered on INPLASY (2021110049) and is available in full on the inplasy.com (https://inplasy.com/inplasy-2021-11-0049/). Results Fifteen relevant studies were finally included, including eight prospective studies and seven retrospective studies. The results of meta-analysis showed that in ODI (P = 0.000), JOA score (P = 0.017), VAS score for lower limb pain (P = 0.027), fusion rate of bone graft at week 12 (P = 0.001), fusion rate of bone graft at last follow-up (P = 0.028), there was a statistical difference between the two groups. The PEEK rod group was superior to the titanium rod group in the above aspects. While in VAS score for LBP (P = 0.396), there was no statistical difference between the two groups. Conclusion Both PEEK rods and titanium rods are effective fixation materials in lumbar fusion surgery. PEEK rods may be superior to titanium rods in improving postoperative function and improving bone graft fusion rates. However, given the limitations of this study, whether these conclusions are applicable needs further research.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Polyetheretherketone (PEEK) rods versus titanium rods for posterior lumbar fusion surgery: a systematic review and meta-analysis
    Wenhao Li
    He Zhao
    Chuanhong Li
    Tao Liu
    Jianbin Guan
    Yongdong Yang
    Xing Yu
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Polyetheretherketone (PEEK) Rods for Lumbar Fusion: A Systematic Review and Meta-Analysis
    Selim, Abdulhafez
    Mercer, Sarah
    Tang, Feng
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (02): : 190 - 200
  • [3] Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis
    Li, Jie
    Cao, Shuai
    Zhao, Bo
    BMC SURGERY, 2024, 24 (01)
  • [4] Titanium-coated polyetheretherketone cages vs. polyetheretherketone cages in lumbar interbody fusion: A systematic review and meta-analysis
    Li, Songfeng
    Li, Xiyong
    Bai, Xiaohui
    Wang, Yunlu
    Han, Pengfei
    Li, Hongzhuo
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 25 (06)
  • [5] A systematic review with meta-analysis of posterior interbody fusion versus posterolateral fusion in lumbar spondylolisthesis
    Liu, Xiaoyang
    Wang, Yipeng
    Qiu, Guixing
    Weng, Xisheng
    Yu, Bin
    EUROPEAN SPINE JOURNAL, 2014, 23 (01) : 43 - 56
  • [6] Clinical and radiological outcomes of titanium cage versus polyetheretherketone cage in lumbar interbody fusion: a systematic review and meta-analysis
    Wang, Haozhong
    Zhang, Hao
    Xiao, Changming
    Zhang, Kaiquan
    Qi, Lisheng
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [7] Titanium-coated PEEK Versus Uncoated PEEK Cages in Lumbar Interbody Fusion A Systematic Review and Meta-analysis of Randomized Controlled Trial
    Lv, Zheng-tao
    Xu, Yong
    Cao, Bin
    Dai, Jun
    Zhang, Si-yuan
    Huang, Jun-ming
    Liang, Shuang
    Jiang, Feng-xian
    CLINICAL SPINE SURGERY, 2023, 36 (05): : 198 - 209
  • [8] A systematic review with meta-analysis of posterior interbody fusion versus posterolateral fusion in lumbar spondylolisthesis
    Xiaoyang Liu
    Yipeng Wang
    Guixing Qiu
    Xisheng Weng
    Bin Yu
    European Spine Journal, 2014, 23 : 43 - 56
  • [9] Comparison of biomechanical effects of polyetheretherketone (PEEK) rods and titanium rods in lumbar long-segment instrumentation: a finite element study
    Li, Chao
    Zhao, Yao
    Qi, Longtao
    Xu, Beiyu
    Yue, Lei
    Zhu, Ranlyu
    Li, Chunde
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [10] Titanium (Ti) cages may be superior to polyetheretherketone (PEEK) cages in lumbar interbody fusion: a systematic review and meta-analysis of clinical and radiological outcomes of spinal interbody fusions using Ti versus PEEK cages
    Jun-Hao Tan
    Chin Kai Cheong
    Hwee Weng Dennis Hey
    European Spine Journal, 2021, 30 : 1285 - 1295