Assessment of Anastomotic Viability With Spectroscopic Real-time Oxygen Saturation Measurement in a Porcine Study

被引:2
作者
Khosrawipour, Tanja [1 ,2 ]
Li, Shiri [1 ,3 ]
Steward, Earl [1 ]
Chaudhry, Haris [1 ]
Nguyen, Danielle [1 ]
Khosrawipour, Veria [1 ]
Jafari, Mehraneh Dorna [1 ]
Pigazzi, Alessio [1 ,3 ]
机构
[1] Univ Calif Irvine, Dept Surg, Div Colorectal Surg, Orange, CA USA
[2] Heinrich Heine Univ Duesseldorf, Univ Hosp Duesseldorf, Dept Surg A, Moorenstr 5, D-40225 Dusseldorf, Germany
[3] Weill Cornell Coll Med, Dept Surg, Div Colon & Rectal Surg, New York Presbyterian Hosp, New York, NY USA
关键词
anastomotic leak; prediction; tissue oximetry; Intra; Ox; vioptix; COLORECTAL SURGERY; DOPPLER ULTRASOUND; TISSUE HYPOXIA; FLUORESCENCE; LEAKAGE; ANGIOGRAPHY; PERFUSION; RESECTION; OXIMETRY;
D O I
10.1177/15533506221127378
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective Anastomotic leakage (AL) is a severe complication following intestinal procedures. Intra.Ox (TM) by ViOptix Inc (Newark, CA, USA) is a novel, FDA-approved spectroscopic device which enables real-time measurement of mixed tissue oxygen saturation (StO(2)). Using a porcine model, this study explores the correlation between StO(2) measurements and AL formation as well as investigates the applicability of Intra.Ox (TM) in the clinical setting. Methods Eleven female swine were divided into 3 groups to explore AL formation in different ischemic conditions. Group 1: 100% mesenteric-vascular ligation, n = 3; Group 2: 50% ligation, n = 5; Group 3: No mesenteric ligation, n = 3. StO(2) at the anastomotic line was measured before and after vessel ligation and anastomosis. Measurements were taken at 6 distinct locations along afferent and efferent loops. AL was evaluated on postoperative day 5 by re-laparotomy. Results AL rate was 100%, 60% and 0% in groups 1, 2 and 3, respectively. Post-anastomotic StO(2) in group 1 (22.9 +/- 18.5%) and 2 (39.2 +/- 20.1%) were significantly lower than in group 3 (53.1 +/- 8.3%, p<.0001). Post-anastomotic StO(2) readings <= 40% indicated AL potential with 100% sensitivity,+ 80% specificity, positive predictive value of 85.7% and negative predictive value of 100%. Conclusion This study demonstrates the value of Intra.Ox (TM) in assessing local perfusion and indicate the association between low StO(2) and AL by providing accurate, real-time, noninvasive tissue oxygenation measurements at anastomotic sites. Further studies are required to investigate the clinical application of this novel device in intestinal surgery.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
[41]   Real-Time Monitoring of Singlet Oxygen and Oxygen Partial Pressure During the Deep Photodynamic Therapy In Vitro [J].
Li, Weitao ;
Huang, Dong ;
Zhang, Yan ;
Liu, Yangyang ;
Gu, Yueqing ;
Qian, Zhiyu .
ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (09) :2737-2745
[42]   Real-time measurement of stapes motion and intracochlear pressure during blast exposure [J].
Bien, Alexander G. ;
Jiang, Shangyuan ;
Gan, Rong Z. .
HEARING RESEARCH, 2023, 429
[43]   Real-Time Visual Measurement With Opponent Hitting Behavior for Table Tennis Robot [J].
Zhang, Kun ;
Cao, Zhiqiang ;
Liu, Jianran ;
Fang, Zaojun ;
Tan, Min .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (04) :811-820
[44]   Real-time intraocular pressure measurement during phacoemulsification in dogs ex vivo [J].
Kang, Seonmi ;
Park, Sangwan ;
Noh, Hyunwoo ;
Kwak, Jiyoon ;
Seo, Kangmoon .
JOURNAL OF VETERINARY MEDICAL SCIENCE, 2015, 77 (06) :685-692
[45]   The role of quantitation of real-time 3-dimensional contrast-enhanced ultrasound in detecting microvascular invasion: an in vivo study [J].
Wang, Zhu ;
Wang, Wei ;
Liu, Guang-Jian ;
Yang, Zheng ;
Chen, Li-Da ;
Huang, Yang ;
Li, Wei ;
Xie, Xiao-Yan ;
Lu, Ming-De ;
Kuang, Ming .
ABDOMINAL RADIOLOGY, 2016, 41 (10) :1973-1979
[46]   Real-time laser speckle contrast imaging for intraoperative neurovascular blood flow assessment: animal experimental study [J].
Konovalov, Anton ;
Grebenev, Fyodor ;
Stavtsev, Dmitry ;
Kozlov, Igor ;
Gadjiagaev, Vadim ;
Piavchenko, Gennadii ;
Telyshev, Dmitry ;
Gerasimenko, Alexander Yu. ;
Meglinski, Igor ;
Zalogin, Savely ;
Artemyev, Anton ;
Golodnev, Grigorii ;
Shumeiko, Tatiana ;
Eliava, Shalva .
SCIENTIFIC REPORTS, 2024, 14 (01)
[47]   Near-Infrared Fluorescence Imaging for Real-Time Intraoperative Guidance in Anastomotic Colorectal Surgery: A Systematic Review of Literature [J].
van den Bos, Jacqueline ;
Al-Taher, Mahdi ;
Schols, Rutger M. ;
van Kuijk, Sander ;
Bouvy, Nicole D. ;
Stassen, Laurents P. S. .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2018, 28 (02) :157-167
[48]   A methodology for probabilistic real-time forecasting - an urban case study [J].
Rene, Jeanne-Rose ;
Madsen, Henrik ;
Mark, Ole .
JOURNAL OF HYDROINFORMATICS, 2013, 15 (03) :751-762
[49]   Real-time porphyrin detection in plaque and caries - a case study [J].
Timoshchuk, Mari-Alina I. ;
Ridge, Jeremy S. ;
Rugg, Amanda L. ;
Nelson, Leonard Y. ;
Kim, Amy S. ;
Seibel, Eric J. .
LASERS IN DENTISTRY XXI, 2015, 9306
[50]   Real-time driving risk assessment based on the psycho-physical field [J].
Zhang, Duo ;
Sun, Jian ;
Wang, Junhua ;
Yu, Rongjie .
JOURNAL OF TRANSPORTATION SAFETY & SECURITY, 2024, 16 (03) :293-322