Assessment of Anastomotic Viability With Spectroscopic Real-time Oxygen Saturation Measurement in a Porcine Study

被引:2
作者
Khosrawipour, Tanja [1 ,2 ]
Li, Shiri [1 ,3 ]
Steward, Earl [1 ]
Chaudhry, Haris [1 ]
Nguyen, Danielle [1 ]
Khosrawipour, Veria [1 ]
Jafari, Mehraneh Dorna [1 ]
Pigazzi, Alessio [1 ,3 ]
机构
[1] Univ Calif Irvine, Dept Surg, Div Colorectal Surg, Orange, CA USA
[2] Heinrich Heine Univ Duesseldorf, Univ Hosp Duesseldorf, Dept Surg A, Moorenstr 5, D-40225 Dusseldorf, Germany
[3] Weill Cornell Coll Med, Dept Surg, Div Colon & Rectal Surg, New York Presbyterian Hosp, New York, NY USA
关键词
anastomotic leak; prediction; tissue oximetry; Intra; Ox; vioptix; COLORECTAL SURGERY; DOPPLER ULTRASOUND; TISSUE HYPOXIA; FLUORESCENCE; LEAKAGE; ANGIOGRAPHY; PERFUSION; RESECTION; OXIMETRY;
D O I
10.1177/15533506221127378
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective Anastomotic leakage (AL) is a severe complication following intestinal procedures. Intra.Ox (TM) by ViOptix Inc (Newark, CA, USA) is a novel, FDA-approved spectroscopic device which enables real-time measurement of mixed tissue oxygen saturation (StO(2)). Using a porcine model, this study explores the correlation between StO(2) measurements and AL formation as well as investigates the applicability of Intra.Ox (TM) in the clinical setting. Methods Eleven female swine were divided into 3 groups to explore AL formation in different ischemic conditions. Group 1: 100% mesenteric-vascular ligation, n = 3; Group 2: 50% ligation, n = 5; Group 3: No mesenteric ligation, n = 3. StO(2) at the anastomotic line was measured before and after vessel ligation and anastomosis. Measurements were taken at 6 distinct locations along afferent and efferent loops. AL was evaluated on postoperative day 5 by re-laparotomy. Results AL rate was 100%, 60% and 0% in groups 1, 2 and 3, respectively. Post-anastomotic StO(2) in group 1 (22.9 +/- 18.5%) and 2 (39.2 +/- 20.1%) were significantly lower than in group 3 (53.1 +/- 8.3%, p<.0001). Post-anastomotic StO(2) readings <= 40% indicated AL potential with 100% sensitivity,+ 80% specificity, positive predictive value of 85.7% and negative predictive value of 100%. Conclusion This study demonstrates the value of Intra.Ox (TM) in assessing local perfusion and indicate the association between low StO(2) and AL by providing accurate, real-time, noninvasive tissue oxygenation measurements at anastomotic sites. Further studies are required to investigate the clinical application of this novel device in intestinal surgery.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
[31]   Evaluation of Myocardial Viability after Myocardial Infarction with Intravenous Real-time Myocardial Contrast Echocardiography [J].
申屠伟慧 ;
邓又斌 ;
黄润青 ;
黎鹏 ;
魏翔 ;
杨好意 ;
张芸 ;
熊莉 ;
余芬 ;
伍玉晗 .
Journal of Huazhong University of Science and Technology(Medical Sciences), 2008, (03) :291-294
[32]   Multimodal fluorescence imaging and spectroscopic techniques for oral cancer screening: a real-time approach [J].
Thapa, Pramila ;
Singh, Veena ;
Bhatt, Sunil ;
Maurya, Kiran ;
Kumar, Virendra ;
Nayyar, Vivek ;
Jot, Kiran ;
Mishra, Deepika ;
Shrivastava, Anurag ;
Mehta, Dalip Singh .
METHODS AND APPLICATIONS IN FLUORESCENCE, 2023, 11 (04)
[33]   Real-time projection MR angiography: Feasibility study [J].
Serfaty, JM ;
Atalar, E ;
Declerck, J ;
Karmakar, P ;
Quick, HH ;
Shunk, KA ;
Heldman, AW ;
Yang, XM .
RADIOLOGY, 2000, 217 (01) :290-295
[34]   Real-Time Continuous Neuromonitoring Combines Transcranial Cerebral Doppler with Near-Infrared Spectroscopy Cerebral Oxygen Saturation During Total Aortic Arch Replacement Procedure: A Pilot Study [J].
Wang, Xiaohua ;
Ji, Bingyang ;
Yang, Baohui ;
Liu, Gang ;
Miao, Na ;
Yang, Jing ;
Liu, Jinping ;
Long, Cun .
ASAIO JOURNAL, 2012, 58 (02) :122-126
[35]   Assessment of cerebrovascular reactivity using real-time BOLD fMRI in children with moyamoya disease: a pilot study [J].
Thomas, Bejoy ;
Logan, William ;
Donner, Elizabeth J. ;
Shroff, Manohar .
CHILDS NERVOUS SYSTEM, 2013, 29 (03) :457-463
[36]   Method for monitoring singlet oxygen quantum yield in real time by time resolved spectroscopy measurement [J].
Liu, Ting ;
Zhang, Xiyu ;
Zhang, Honglin ;
Zhao, Hua ;
Zhang, Zhiguo ;
Tian, Ye .
OPTICS EXPRESS, 2020, 28 (18) :25757-25766
[37]   Rapid ventricular assessment using real-time interactive multislice MRI [J].
Nayak, KS ;
Pauly, JM ;
Nishimura, DG ;
Hu, BS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (03) :371-375
[38]   Real-time driving risk assessment using deep learning with XGBoost [J].
Shi, Liang ;
Qian, Chen ;
Guo, Feng .
ACCIDENT ANALYSIS AND PREVENTION, 2022, 178
[39]   Improved method for Real-Time Transient Stability Assessment of Power Systems [J].
Echeverria, D. E. ;
Rueda, J. L. ;
Colome, D. G. ;
Erlich, I. .
2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
[40]   Quantitative Assessment of the Accuracy of Real-Time Virtual Sonography for Liver Surgery [J].
Miyata, Akinori ;
Arita, Junichi ;
Shirata, Chikara ;
Abe, Satoru ;
Akamatsu, Nobuhisa ;
Kaneko, Junichi ;
Kokudo, Norihiro ;
Hasegawa, Kiyoshi .
SURGICAL INNOVATION, 2020, 27 (01) :60-67