Assessment of Anastomotic Viability With Spectroscopic Real-time Oxygen Saturation Measurement in a Porcine Study

被引:2
作者
Khosrawipour, Tanja [1 ,2 ]
Li, Shiri [1 ,3 ]
Steward, Earl [1 ]
Chaudhry, Haris [1 ]
Nguyen, Danielle [1 ]
Khosrawipour, Veria [1 ]
Jafari, Mehraneh Dorna [1 ]
Pigazzi, Alessio [1 ,3 ]
机构
[1] Univ Calif Irvine, Dept Surg, Div Colorectal Surg, Orange, CA USA
[2] Heinrich Heine Univ Duesseldorf, Univ Hosp Duesseldorf, Dept Surg A, Moorenstr 5, D-40225 Dusseldorf, Germany
[3] Weill Cornell Coll Med, Dept Surg, Div Colon & Rectal Surg, New York Presbyterian Hosp, New York, NY USA
关键词
anastomotic leak; prediction; tissue oximetry; Intra; Ox; vioptix; COLORECTAL SURGERY; DOPPLER ULTRASOUND; TISSUE HYPOXIA; FLUORESCENCE; LEAKAGE; ANGIOGRAPHY; PERFUSION; RESECTION; OXIMETRY;
D O I
10.1177/15533506221127378
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective Anastomotic leakage (AL) is a severe complication following intestinal procedures. Intra.Ox (TM) by ViOptix Inc (Newark, CA, USA) is a novel, FDA-approved spectroscopic device which enables real-time measurement of mixed tissue oxygen saturation (StO(2)). Using a porcine model, this study explores the correlation between StO(2) measurements and AL formation as well as investigates the applicability of Intra.Ox (TM) in the clinical setting. Methods Eleven female swine were divided into 3 groups to explore AL formation in different ischemic conditions. Group 1: 100% mesenteric-vascular ligation, n = 3; Group 2: 50% ligation, n = 5; Group 3: No mesenteric ligation, n = 3. StO(2) at the anastomotic line was measured before and after vessel ligation and anastomosis. Measurements were taken at 6 distinct locations along afferent and efferent loops. AL was evaluated on postoperative day 5 by re-laparotomy. Results AL rate was 100%, 60% and 0% in groups 1, 2 and 3, respectively. Post-anastomotic StO(2) in group 1 (22.9 +/- 18.5%) and 2 (39.2 +/- 20.1%) were significantly lower than in group 3 (53.1 +/- 8.3%, p<.0001). Post-anastomotic StO(2) readings <= 40% indicated AL potential with 100% sensitivity,+ 80% specificity, positive predictive value of 85.7% and negative predictive value of 100%. Conclusion This study demonstrates the value of Intra.Ox (TM) in assessing local perfusion and indicate the association between low StO(2) and AL by providing accurate, real-time, noninvasive tissue oxygenation measurements at anastomotic sites. Further studies are required to investigate the clinical application of this novel device in intestinal surgery.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
[21]   Real-time quantification of bowel perfusion using Laparoscopic Laser Speckle Contrast Imaging (LSCI) in a porcine model [J].
Mehrotra, Saloni ;
Liu, Yao Z. ;
Nwaiwu, Chibueze A. ;
Buharin, Vasiliy E. ;
Stolyarov, Roman ;
Schwaitzberg, Steven D. ;
Kalady, Matthew F. ;
Kim, Peter C. W. .
BMC SURGERY, 2023, 23 (01)
[22]   Real-time luminescence microspectroscopy monitoring of singlet oxygen in individual cells [J].
Scholz, Marek ;
Dedic, Roman ;
Valenta, Jan ;
Breitenbach, Thomas ;
Hala, Jan .
PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2014, 13 (08) :1203-1212
[23]   A real-time, bioluminescent annexin V assay for the assessment of apoptosis [J].
Kupcho, Kevin ;
Shultz, John ;
Hurst, Robin ;
Hartnett, Jim ;
Zhou, Wenhui ;
Machleidt, Thomas ;
Grailer, Jamison ;
Worzella, Tracy ;
Riss, Terry ;
Lazar, Dan ;
Cali, James J. ;
Niles, Andrew .
APOPTOSIS, 2019, 24 (1-2) :184-197
[24]   In vivo, noncontact, real-time, optical and spectroscopic assessment of the immediate local physiological response to spinal cord injury in a rat model [J].
Fillioe, Seth ;
Bishop, Kyle Kelly ;
Jannini, Alexander Vincent Struck ;
Kim, Jon ;
McDonough, Ricky ;
Ortiz, Steve ;
Goodisman, Jerry ;
Hasenwinkel, Julie ;
Chaiken, J. .
OPTICAL BIOPSY XVI: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2018, 10489
[25]   Real-Time Blood Flow Assessment Using ICG Fluorescence Imaging During Hepatobiliary and Pancreatic Surgery with Consideration of Vascular Reconstruction [J].
Fujimoto, Hiroyuki ;
Kinoshita, Masahiko ;
Ahn, Changgi ;
Yasuda, Takuto ;
Hatta, Kosuke ;
Yoshida, Mizuki ;
Nakanishi, Koichi ;
Kawaguchi, Takahito ;
Tani, Naoki ;
Okada, Takuma ;
Watanabe, Genki ;
Tanaka, Ryota ;
Kurihara, Shigeaki ;
Nishio, Kohei ;
Shinkawa, Hiroji ;
Kimura, Kenjiro ;
Ishizawa, Takeaki .
CANCERS, 2025, 17 (05)
[26]   Development of Viscosity Real-Time Measurement System Based on Capillary Method [J].
Wang, Xiaojie ;
Liu, Jidong ;
Ma, Yingjie ;
Huo, Jianing ;
Dai, Chenkai ;
Fang, Lide .
IEEE SENSORS JOURNAL, 2023, 23 (20) :25451-25459
[27]   Real-Time Measurement of Rectal Mucosal Microcirculation During Cardiopulmonary Bypass [J].
Kiessling, Arndt-H. ;
Reyher, Christian ;
Philipp, Michael ;
Beiras-Fernandez, Andres ;
Moritz, Anton .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (01) :89-94
[28]   Evaluation of myocardial viability after myocardial infarction with intravenous real-time myocardial contrast echocardiography [J].
Shentu, Weihui ;
Deng, Youbin ;
Huang, Runqing ;
Li, Peng ;
Wei, Xiang ;
Yang, Haoyi ;
Zhang, Yun ;
Xiong, Li ;
Yu, Fen ;
Wu, Yuhan .
JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2008, 28 (03) :291-294
[29]   Non-invasive real-time monitoring of cell concentration and viability using Doppler ultrasound [J].
Akbari, Samin ;
Anderson, Phillip ;
Zang, Han ;
Ganjian, Amin ;
Balke, Robert ;
Kwon, Taehong ;
Pollard, David .
SLAS TECHNOLOGY, 2022, 27 (06) :368-375
[30]   Evaluation of myocardial viability after myocardial infarction with intravenous real-time myocardial contrast echocardiography [J].
Weihui Shentu ;
Youbin Deng ;
Runqing Huang ;
Peng Li ;
Xiang Wei ;
Haoyi Yang ;
Yun Zhang ;
Li Xiong ;
Fen Yu ;
Yuhan Wu .
Journal of Huazhong University of Science and Technology [Medical Sciences], 2008, 28 :291-294