Gait Abnormality Detection in Unilateral Trans-Tibial Amputee in Real-Time Gait Using Wearable Setup

被引:5
作者
Rathore, Radheshyam [1 ]
Singh, Amit Kumar [2 ,3 ]
Chaudhary, Himanshu [1 ]
Kandan, Karthikeyan [4 ]
机构
[1] Malaviya Natl Inst Technol, Dept Mech Engn, Jaipur 302017, Rajasthan, India
[2] Natl Inst Technol Calicut, Dept Mech Engn, Calicut 673601, Kerala, India
[3] Malaviya Natl Inst Technol, Jaipur 302017, Rajasthan, India
[4] De Montfort Univ, Sch Engn & Sustainable Dev, Dept Mech Engn, Leicester LE1 9BH, England
关键词
Data processing; gait analysis; knee flexion; potentiometer; pressure insole; pressure sensors; transtibial (TT) amputation; PATELLAR TENDON BEARING; LIMB; BIOMECHANICS; JOINT; OSTEOARTHRITIS; TRAJECTORIES; PROSTHESIS; WALKING; MODEL; FOOT;
D O I
10.1109/JSEN.2023.3263399
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The presented study proposes a novel approach to detect gait abnormalities in unilateral trans-tibial (TT) amputees using a wearable setup. The system uses force-sensitive resistors and potentiometers to collect data on the user's gait patterns. A machine-learning algorithm based on Extreme Learning Machines is utilized to classify the gait patterns as normal or abnormal. The system is evaluated on a dataset of healthy and unilateral TT amputees, and the results reveal that the ELM-based classification technique achieved high accuracy, sensitivity, specificity, and F1 score. The proposed wearable gait setup is tested by conducting a standard 6-m walk test, and the collected data is segmented into stance and swing phases. The study also compares various gait parameters of healthy and amputated subjects, and the results show significant asymmetry in the amputated subjects. The proposed setup also detects asymmetry in force distribution under each foot. The study's findings reveal that the proposed wearable gait setup is a reliable and effective tool for gait analysis in unilateral TT amputees, and the results are comparable with those obtained using a Vicon gait measurement system.
引用
收藏
页码:12567 / 12573
页数:7
相关论文
共 40 条
[1]  
BAKER PA, 1990, PROSTHET ORTHOT INT, V14, P80
[2]  
Semwal VB, 2017, Arxiv, DOI arXiv:1710.06548
[3]   Fusion of Multi-Sensor-Based Biomechanical Gait Analysis Using Vision and Wearable Sensor [J].
Bijalwan, Vishwanath ;
Semwal, Vijay Bhaskar ;
Mandal, T. K. .
IEEE SENSORS JOURNAL, 2021, 21 (13) :14213-14220
[4]   Effect of prosthetic gel liner thickness on gait biomechanics and pressure distribution within the transtibial socket [J].
Boutwell, Erin ;
Stine, Rebecca ;
Hansen, Andrew ;
Tucker, Kerice ;
Gard, Steven .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2012, 49 (02) :227-240
[5]  
BREAKEY J, 1976, ORTHOTICS PROSTHET, V30, P17
[6]  
Cheung C, 1999, PROSTHETICS ORTHOTIC, V7, P131
[7]  
Dingwell JB, 1996, PROSTHET ORTHOT INT, V20, P101
[8]   A functional evaluation of prosthetic foot kinematics during lower-limb amputee gait [J].
Goujon, H. ;
Bonnet, X. ;
Sautreuil, P. ;
Maurisset, M. ;
Darmon, L. ;
Fode, P. ;
Lavaste, F. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2006, 30 (02) :213-223
[9]   Occluded Gait reconstruction in multi person Gait environment using different numerical methods [J].
Gupta, Anjali ;
Semwal, Vijay Bhaskar .
MULTIMEDIA TOOLS AND APPLICATIONS, 2022, 81 (16) :23421-23448
[10]   Total surface bearing below-knee prosthesis: Advantages, disadvantages, and clinical implications [J].
Hachisuka, K ;
Dozono, K ;
Ogata, H ;
Ohmine, S ;
Shitama, H ;
Shinkoda, K .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (07) :783-789