Towards quantitative digital subtraction perfusion angiography: An animal study

被引:3
作者
Su, Ruisheng [1 ]
van der Sluijs, P. Matthijs [1 ]
Bobi, Joaquim [2 ]
Taha, Aladdin [2 ]
van Beusekom, Heleen M. M. [2 ]
van der Lugt, Aad [1 ]
Niessen, Wiro J. [1 ,3 ]
Ruijters, Danny [4 ]
van Walsum, Theo [1 ]
机构
[1] Univ Med Ctr, Dept Radiol & Nucl Med, Erasmus MC, Rotterdam, Netherlands
[2] Univ Med Ctr, Dept Expt Cardiol, Erasmus MC, Rotterdam, Netherlands
[3] Delft Univ Technol, Fac Appl Sci, Delft, Netherlands
[4] Philips Healthcare, Best, Netherlands
关键词
cerebral blood volume; deconvolution; digital subtraction angiography; ischemic stroke; perfusion imaging; swine; time intensity curve; ACUTE ISCHEMIC-STROKE; CT; BRAIN; ENHANCEMENT; CURVES;
D O I
10.1002/mp.16473
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundX-ray digital subtraction angiography (DSA) is the imaging modality for peri-procedural guidance and treatment evaluation in (neuro-) vascular interventions. Perfusion image construction from DSA, as a means of quantitatively depicting cerebral hemodynamics, has been shown feasible. However, the quantitative property of perfusion DSA has not been well studied. PurposeTo comparatively study the independence of deconvolution-based perfusion DSA with respect to varying injection protocols, as well as its sensitivity to alterations in brain conditions. MethodsWe developed a deconvolution-based algorithm to compute perfusion parametric images from DSA, including cerebral blood volume (CBVDSA$_{DSA}$), cerebral blood flow (CBFDSA$_{DSA}$), time to maximum (Tmax), and mean transit time (MTTDSA$_{DSA}$) and applied it to DSA sequences obtained from two swine models. We also extracted the time intensity curve (TIC)-derived parameters, that is, area under the curve (AUC), peak concentration of the curve, and the time to peak (TTP) from these sequences. Deconvolution-based parameters were quantitatively compared to TIC-derived parameters in terms of consistency upon variations in injection profile and time resolution of DSA, as well as sensitivity to alterations of cerebral condition. ResultsComparing to TIC-derived parameters, the standard deviation (SD) of deconvolution-based parameters (normalized with respect to the mean) are two to five times smaller, indicating that they are more consistent across different injection protocols and time resolutions. Upon ischemic stroke induced in a swine model, the sensitivities of deconvolution-based parameters are equal to, if not higher than, those of TIC-derived parameters. ConclusionsIn comparison to TIC-derived parameters, deconvolution-based perfusion imaging in DSA shows significantly higher quantitative reliability against variations in injection protocols across different time resolutions, and is sensitive to alterations in cerebral hemodynamics. The quantitative nature of perfusion angiography may allow for objective treatment assessment in neurovascular interventions.
引用
收藏
页码:4055 / 4066
页数:12
相关论文
共 50 条
  • [41] Quantitative flow measurement by digital subtraction angiography in cerebral carotid stenosis using optical flow method
    Huang, Tzung-Chi
    Wu, Tung-Hsin
    Lin, Yang-Hsien
    Guo, Wan-Yuo
    Huang, Wei-Chien
    Lin, Chung-Jung
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) : 227 - 235
  • [42] Application of digital subtraction angiography in canine hindlimb arteriography
    Wang, Xue
    Li, Lubin
    Wang, Chengwei
    Zhang, Shiyong
    Wang, Jie
    Chen, Tiannan
    VASCULAR, 2022, 30 (03) : 474 - 480
  • [43] INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY IN PATIENTS WITH AORTOARTERITIS (TAKAYASUS)
    LIU, YQ
    LING, J
    WANG, ZL
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1990, 13 (02) : 83 - 87
  • [44] CT Perfusion with Angiography as a Substitute for both Conventional Digital Subtraction Angiography and Acetazolamide-Challenged SPECT in the Follow-Up of Postbypass Patients
    Park, Jung Cheol
    Kim, Jeong Eun
    Kang, Hyun-Seung
    Sohn, Chul-Ho
    Lee, Dong Soo
    Oh, Chang Wan
    Han, Moon Hee
    CEREBROVASCULAR DISEASES, 2010, 30 (06) : 547 - 555
  • [45] Digital subtraction angiography for arteriovenous malformations in stereotactic radiosurgery
    Piovan, E
    DalSasso, M
    Urbani, GP
    Sartori, R
    Foroni, R
    Benati, A
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 : 57 - 62
  • [46] Pulmonary digital subtraction angiography: Ready for prime time
    Darcy, MD
    RADIOLOGY, 1998, 207 (01) : 11 - 12
  • [47] Quantification of arterial flow using digital subtraction angiography
    Bonnefous, Odile
    Pereira, Vitor Mendes
    Ouared, Rafik
    Brina, Olivier
    Aerts, Hans
    Hermans, Roel
    van Nijnatten, Fred
    Stawiaski, Jean
    Ruijters, Daniel
    MEDICAL PHYSICS, 2012, 39 (10) : 6264 - 6275
  • [48] THE ROLE OF DIGITAL SUBTRACTION ANGIOGRAPHY IN THE QUANTITATION OF CORONARY STENOSIS
    KATRITSIS, D
    WEBBPEPLOE, MM
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1990, 29 (03) : 277 - 283
  • [49] Digital subtraction angiography of a persistent trigeminal artery variant
    Temizoz, Osman
    Genchellac, Hakan
    Unlu, Ercuement
    Cagli, Bekir
    Ozdemir, Hueseyin
    Demir, M. Kemal
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2010, 16 (03) : 245 - 247
  • [50] Upper bounds for quantization errors in digital subtraction angiography
    Reza, A
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2003, E86D (11) : 2463 - 2471