Towards quantitative digital subtraction perfusion angiography: An animal study

被引:3
作者
Su, Ruisheng [1 ]
van der Sluijs, P. Matthijs [1 ]
Bobi, Joaquim [2 ]
Taha, Aladdin [2 ]
van Beusekom, Heleen M. M. [2 ]
van der Lugt, Aad [1 ]
Niessen, Wiro J. [1 ,3 ]
Ruijters, Danny [4 ]
van Walsum, Theo [1 ]
机构
[1] Univ Med Ctr, Dept Radiol & Nucl Med, Erasmus MC, Rotterdam, Netherlands
[2] Univ Med Ctr, Dept Expt Cardiol, Erasmus MC, Rotterdam, Netherlands
[3] Delft Univ Technol, Fac Appl Sci, Delft, Netherlands
[4] Philips Healthcare, Best, Netherlands
关键词
cerebral blood volume; deconvolution; digital subtraction angiography; ischemic stroke; perfusion imaging; swine; time intensity curve; ACUTE ISCHEMIC-STROKE; CT; BRAIN; ENHANCEMENT; CURVES;
D O I
10.1002/mp.16473
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundX-ray digital subtraction angiography (DSA) is the imaging modality for peri-procedural guidance and treatment evaluation in (neuro-) vascular interventions. Perfusion image construction from DSA, as a means of quantitatively depicting cerebral hemodynamics, has been shown feasible. However, the quantitative property of perfusion DSA has not been well studied. PurposeTo comparatively study the independence of deconvolution-based perfusion DSA with respect to varying injection protocols, as well as its sensitivity to alterations in brain conditions. MethodsWe developed a deconvolution-based algorithm to compute perfusion parametric images from DSA, including cerebral blood volume (CBVDSA$_{DSA}$), cerebral blood flow (CBFDSA$_{DSA}$), time to maximum (Tmax), and mean transit time (MTTDSA$_{DSA}$) and applied it to DSA sequences obtained from two swine models. We also extracted the time intensity curve (TIC)-derived parameters, that is, area under the curve (AUC), peak concentration of the curve, and the time to peak (TTP) from these sequences. Deconvolution-based parameters were quantitatively compared to TIC-derived parameters in terms of consistency upon variations in injection profile and time resolution of DSA, as well as sensitivity to alterations of cerebral condition. ResultsComparing to TIC-derived parameters, the standard deviation (SD) of deconvolution-based parameters (normalized with respect to the mean) are two to five times smaller, indicating that they are more consistent across different injection protocols and time resolutions. Upon ischemic stroke induced in a swine model, the sensitivities of deconvolution-based parameters are equal to, if not higher than, those of TIC-derived parameters. ConclusionsIn comparison to TIC-derived parameters, deconvolution-based perfusion imaging in DSA shows significantly higher quantitative reliability against variations in injection protocols across different time resolutions, and is sensitive to alterations in cerebral hemodynamics. The quantitative nature of perfusion angiography may allow for objective treatment assessment in neurovascular interventions.
引用
收藏
页码:4055 / 4066
页数:12
相关论文
共 50 条
  • [31] The principle of digital subtraction angiography and radiological protection
    Okamoto, K
    Ito, J
    Sakai, K
    Yoshimura, S
    INTERVENTIONAL NEURORADIOLOGY, 2000, 6 : 25 - 31
  • [32] Assessment of small hepatocellular carcinoma: perfusion quantification and time-concentration curve evaluation using color-coded and quantitative digital subtraction angiography
    Chen, Chien-Wei
    Hsu, Li-Sheng
    Weng, Jun-Cheng
    Weng, Hsu-Huei
    Ye, Yu-Ling
    Hsu, Sheng-Lung
    Lin, Wei-Ming
    MEDICINE, 2018, 97 (48)
  • [33] Machine Learning Application With Quantitative Digital Subtraction Angiography for Detection of Hemorrhagic Brain Arteriovenous Malformations
    Hong, Jia-Sheng
    Lin, Chung-Jung
    Lin, Yue-Hsin
    Lee, Cheng-Chia
    Yang, Huai-Che
    Meng, Ling-Hsuan
    Lin, Te-Ming
    Hu, Yong-Sin
    Guo, Wan-Yuo
    Chu, Wei-Fa
    Wu, Yu-Te
    IEEE ACCESS, 2020, 8 : 204573 - 204584
  • [34] Quantitative analysis of digital subtraction angiography using optical flow method on occlusive cerebrovascular disease
    Wu, Tung-Hsin
    Lin, Chung-Jung
    Lin, Yang-Hsien
    Guo, Wan-Yuo
    Huang, Tzung-Chi
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 111 (03) : 693 - 700
  • [35] A high-precision contrast injector for small animal X-ray digital subtraction angiography
    De Lin, Ming
    Ning, Lutao
    Badea, Cristian T.
    Mistry, Nilesh N.
    Qi, Yi
    Johnson, G. Allan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (03) : 1082 - 1091
  • [36] Comparative study of multi-slice CT angiography with digital subtraction angiography in the blood supply of meningiomas
    Han, Xiangjun
    Zhan, Yuefu
    Chen, Jianqiang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2012, 3 (01) : 31 - 36
  • [37] Velocity Criteria for Intracranial Stenosis Revisited An International Multicenter Study of Transcranial Doppler and Digital Subtraction Angiography
    Zhao, Limin
    Barlinn, Kristian
    Sharma, Vijay K.
    Tsivgoulis, Georgios
    Cava, Luis F.
    Vasdekis, Spyros N.
    Teoh, Hock Luen
    Triantafyllou, Nikos
    Chan, Bernard P. L.
    Sharma, Arvind
    Voumvourakis, Konstantinos
    Stamboulis, Elefterios
    Saqqur, Maher
    Harrigan, Mark R.
    Albright, Karen C.
    Alexandrov, Andrei V.
    STROKE, 2011, 42 (12) : 3429 - 3434
  • [38] Usefulness of CT angiography for characterizing cerebral arteriovenous malformations presenting as hemorrhage: comparison with digital subtraction angiography
    Zwanzger, C.
    Lopez-Rueda, A.
    Campodonico, D.
    Rosati, S.
    Blasco, J.
    San Roman, L.
    Macho, J.
    RADIOLOGIA, 2020, 62 (05): : 392 - 399
  • [39] New grading of moyamoya disease using color-coded parametric quantitative digital subtraction angiography
    Hung, Sheng-Che
    Liang, Muh-Lii
    Lin, Chun-Fu
    Lin, Chung-Jung
    Guo, Wan-Yuo
    Chang, Feng-Chi
    Wong, Tai-Tong
    Chang, Cheng-Yen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2014, 77 (08) : 437 - 442
  • [40] Association of intracranial arteriovenous malformation embolization with more rapid rate of perfusion in the peri-nidal region on color-coded quantitative digital subtraction angiography
    Shellikeri, Sphoorti
    Bai, Harrison
    Setser, Randolph M.
    Hurst, Robert W.
    Cahill, Anne Marie
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (09) : 902 - +