Towards quantitative digital subtraction perfusion angiography: An animal study

被引:3
|
作者
Su, Ruisheng [1 ]
van der Sluijs, P. Matthijs [1 ]
Bobi, Joaquim [2 ]
Taha, Aladdin [2 ]
van Beusekom, Heleen M. M. [2 ]
van der Lugt, Aad [1 ]
Niessen, Wiro J. [1 ,3 ]
Ruijters, Danny [4 ]
van Walsum, Theo [1 ]
机构
[1] Univ Med Ctr, Dept Radiol & Nucl Med, Erasmus MC, Rotterdam, Netherlands
[2] Univ Med Ctr, Dept Expt Cardiol, Erasmus MC, Rotterdam, Netherlands
[3] Delft Univ Technol, Fac Appl Sci, Delft, Netherlands
[4] Philips Healthcare, Best, Netherlands
关键词
cerebral blood volume; deconvolution; digital subtraction angiography; ischemic stroke; perfusion imaging; swine; time intensity curve; ACUTE ISCHEMIC-STROKE; CT; BRAIN; ENHANCEMENT; CURVES;
D O I
10.1002/mp.16473
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundX-ray digital subtraction angiography (DSA) is the imaging modality for peri-procedural guidance and treatment evaluation in (neuro-) vascular interventions. Perfusion image construction from DSA, as a means of quantitatively depicting cerebral hemodynamics, has been shown feasible. However, the quantitative property of perfusion DSA has not been well studied. PurposeTo comparatively study the independence of deconvolution-based perfusion DSA with respect to varying injection protocols, as well as its sensitivity to alterations in brain conditions. MethodsWe developed a deconvolution-based algorithm to compute perfusion parametric images from DSA, including cerebral blood volume (CBVDSA$_{DSA}$), cerebral blood flow (CBFDSA$_{DSA}$), time to maximum (Tmax), and mean transit time (MTTDSA$_{DSA}$) and applied it to DSA sequences obtained from two swine models. We also extracted the time intensity curve (TIC)-derived parameters, that is, area under the curve (AUC), peak concentration of the curve, and the time to peak (TTP) from these sequences. Deconvolution-based parameters were quantitatively compared to TIC-derived parameters in terms of consistency upon variations in injection profile and time resolution of DSA, as well as sensitivity to alterations of cerebral condition. ResultsComparing to TIC-derived parameters, the standard deviation (SD) of deconvolution-based parameters (normalized with respect to the mean) are two to five times smaller, indicating that they are more consistent across different injection protocols and time resolutions. Upon ischemic stroke induced in a swine model, the sensitivities of deconvolution-based parameters are equal to, if not higher than, those of TIC-derived parameters. ConclusionsIn comparison to TIC-derived parameters, deconvolution-based perfusion imaging in DSA shows significantly higher quantitative reliability against variations in injection protocols across different time resolutions, and is sensitive to alterations in cerebral hemodynamics. The quantitative nature of perfusion angiography may allow for objective treatment assessment in neurovascular interventions.
引用
收藏
页码:4055 / 4066
页数:12
相关论文
共 50 条
  • [1] Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography
    Lin, MingDe
    Marshall, Craig T.
    Qi, Yi
    Johnston, Samuel M.
    Badea, Cristian T.
    Piantadosi, Claude A.
    Johnson, G. Allan
    MEDICAL PHYSICS, 2009, 36 (11) : 5347 - 5358
  • [2] perfDSA: Automatic Perfusion Imaging in Cerebral Digital Subtraction Angiography
    Su, Ruisheng
    van der Sluijs, P. Matthijs
    Marc, Flavius-Gabriel
    te Nijenhuis, Frank
    Cornelissen, Sandra A. P.
    Roozenbeek, Bob
    van Zwam, Wim H.
    van der Lugt, Aad
    Ruijters, Danny
    Pluim, Josien
    van Walsum, Theo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2025,
  • [3] Tomographic digital subtraction angiography for lung perfusion estimation in rodents
    Badea, Cristian T.
    Hedlund, Laurence W.
    Lin, Ming De
    Mackel, Julie S. Boslego
    Samei, Ehsan
    Johnson, G. Allan
    MEDICAL PHYSICS, 2007, 34 (05) : 1546 - 1555
  • [4] DETERMINATION OF MYOCARDIAL PERFUSION BY MEANS OF DIGITAL SUBTRACTION ANGIOGRAPHY
    JEHLE, J
    SCHMIEL, FK
    SPILLER, P
    HAUDE, M
    MACHNIG, T
    POLITZ, B
    HERZ KREISLAUF, 1991, 23 (02): : 41 - 45
  • [5] Optimized radiographic spectra for small animal digital subtraction angiography
    De Lin, Ming
    Samei, Ehsan
    Badea, Cristian T.
    Yoshizumi, Terry T.
    Johnson, G. Allan
    MEDICAL PHYSICS, 2006, 33 (11) : 4249 - 4257
  • [6] Evaluating cerebral hemodynamics using quantitative digital subtraction angiography and flat-detector computed tomography perfusion imaging: A comparative study in patients with carotid stenosis
    Chen, Liang-Wei
    Lin, Chung-Jung
    Guo, Wan-Yuo
    Hung, Sheng-Che
    Lee, Han-Jui
    Chen, Ko-Kung
    Chang, Feng-Chi
    Luo, Chao-Bao
    Chu, Wei-Fa
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2018, 81 (11) : 977 - 984
  • [7] Digital subtraction angiography in the study of intracranial tumors
    Fabris, G
    Aprile, I
    Biasizzo, E
    DeColle, MC
    Lavaroni, A
    Tommasini, G
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 149 - 150
  • [8] Quantitative assessment of angiographic perfusion reduction using color-coded digital subtraction angiography during transarterial chemoembolization
    Wang, Ji
    Cheng, Jie-Jun
    Huang, Kai-Yi
    Zhuang, Zhi-Guo
    Zhang, Xue-Bin
    Chi, Jia-Chang
    Hua, Xiao-Lan
    Xu, Jian-Rong
    ABDOMINAL RADIOLOGY, 2016, 41 (03) : 545 - 552
  • [9] Peritherapeutic quantitative flow analysis of arteriovenous malformation on digital subtraction angiography
    Huang, Tzung-Chi
    Wu, Tung-Hsin
    Lin, Chung-Jung
    Mok, Greta S. P.
    Guo, Wan-Yuo
    JOURNAL OF VASCULAR SURGERY, 2012, 56 (03) : 812 - 815
  • [10] Collateral Status in Ischemic Stroke: A Comparison of Computed Tomography Angiography, Computed Tomography Perfusion, and Digital Subtraction Angiography
    Kauw, Frans
    Dankbaar, Jan W.
    Martin, Blake W.
    Ding, Victoria Y.
    Boothroyd, Derek B.
    van Ommen, Fasco
    de Jong, Hugo W. A. M.
    Kappelle, L. Jaap
    Velthuis, Birgitta K.
    Heit, Jeremy J.
    Wintermark, Max
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (06) : 984 - 992