Comparative dosimetric analysis of volumetric modulated arc therapy based craniospinal irradiation plans between Halcyon ring gantry and TrueBeam C-arm linear accelerator

被引:4
|
作者
Sarkar, Biplab [1 ]
Biswal, Subhra Snigdha [1 ]
Shahid, Tanweer [1 ]
Ghosh, Tanmoy [1 ]
Bhattacharya, Jibak [1 ]
De, Arundhati [1 ]
Mukherjee, Mukti [1 ]
Ganesh, Tharmarnadar [2 ]
Cozzi, Luca [3 ,4 ,5 ]
机构
[1] Apollo Multispecial Hosp, Dept Radiat Oncol, Kolkata, India
[2] Manipal Hosp, New Delhi, India
[3] Humanitas Res Hosp, Canc Ctr, Radiotherapy & Radiosurg Dept, Via Manzoni 56, I-20089 Rozzano, Italy
[4] Humanitas Univ, Dept Biomed Sci, Via R Levi Montalcini 4, I-20090 Milan, Italy
[5] Varian Med Syst, Palo Alto, CA USA
关键词
RADIATION-THERAPY; RADIOTHERAPY; JUNCTION;
D O I
10.1038/s41598-023-30429-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study evaluates the volumetric modulated arc therapy (VMAT) dosimetric comparison between Halcyon ring gantry and TrueBeam c-arm linear accelerators for craniospinal irradiation (CSI) of the neuro-axis. 25 patients, who received treatment for medulloblastoma and primitive neuro-ectodermal tumors between 2018 and 2021, were planned for VMAT in True Beam (TB), and Halcyon (HAL) linear accelerators using 6 MV unflattened (FFF) photon beams (HALFFF and TBFFF). Dose-volume statistics for the target and organs at risk (OARs) and the total number of monitoring units (MUs) in the treatment plans were compared which included dose received by 95% PTV volume (V95%), volume receiving >= 107% dose, homogeneity index (HI), conformity index (PI), MU and dose spillage (D10%, D30%, D50%, D70%, D90%). In all 26 OARs were considered of which five were serial and the remaining were parallel structures. For the former, the dose received by 0.2 cm(3), volume = D0.2 cm(3)) were evaluated and for the latter mean dose were evaluated. Both arms were statistically compared with paired sample t-test with a significant value of <= 0.05. 11 patients received treatment with the Halcyon and the rest 14 in the TrueBeam C-arm linear accelerator. Patients in the low- and intermediate-risk category (n = 13) received 23.4 Gy in 13 fractions. The remaining patients were in the high-risk category and received 35 Gy in 21 fractions or 36 Gy in 20 fractions. For HALFFF and TBFFF, PTVV95% were 97.5 +/- 0.8% and 97.4 +/- 0.9% respectively (p = 0.371) while the V107% were 0.6 +/- 0.4% and 0.5 +/- 0.5 respectively (p = 0.504). However, the number of monitoring units showed statistical significance (p < 0.001) with values of 1331.9 +/- 243.4 MU and 1089 +/- 206.7 MU respectively for the HAL and TB plans. The differences in spillage dose were also statistically significant, favouring HAL plans at D30% (p = 0.002), D50% (p < 0.001), D70% (p = 0.039), and D90% (p = 0.01) level except for D10% (p = 0.090). Conformity index also showed statistical significance with PI_HAL = 0.9 +/- 0.02 and PI_TB = 0.89 +/- 0.03 (p = 0.029). For 10 of the 21 parallel structures, the mean dose differences were statistically significant in favouring of HAL plans. Halcyon based VMAT CSI plans are dosimetrically superior in terms of organ dose, especially for the large organs, and offer lower spillage doses than the TrueBeam plans. Plans generated by both linear accelerators are suitable for the patients' treatments.
引用
收藏
页数:10
相关论文
共 14 条
  • [1] Comparative dosimetric, setup margin, and treatment time analysis between ring gantry and C-Arm linear accelerators for VMAT-based craniospinal irradiation plans
    Biswal, Subhra S.
    Sarkar, Biplab
    Goyal, Monika
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (01) : 224 - 231
  • [2] Preclinical validation and treatment of volumetric modulated arc therapy based total bone marrow irradiation in Halcyon™ ring gantry linear accelerator
    Shahid, Tanweer
    Mandal, Sourav
    Biswal, Subhra Snigdha
    De, Arundhati
    Mukherjee, Mukti
    Chowdhury, Sandipan Roy
    Chakrapani, Anupam
    George, Kirubha
    Bhattacharya, Jibak
    Soren, Prosenjit
    Ghosh, Tanmoy
    Sarkar, Biplab
    Cozzi, Luca
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [3] Volumetric modulated arc therapy for hippocampal-sparing prophylactic cranial irradiation: Planning comparison of Halcyon and C-arm accelerators
    Sun, Tao
    Lin, Xiutong
    Li, Kuo
    Qiu, Qingtao
    Duan, Jinghao
    Zhang, Guifang
    Yin, Yong
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [4] The dosimetric impact of trade-off optimization in high-quality Craniospinal Irradiation plans based on volumetric modulated arc therapy technique
    Biswal, Subhra S.
    Sarkar, Biplab
    Goyal, Monika
    Ganesh, Tharmarnadar
    MEDICAL DOSIMETRY, 2025, 50 (01) : 36 - 42
  • [5] Craniospinal Irradiation: A Dosimetric Comparison Between O-Ring Linac and Conventional C-arm Linac
    Stroubinis, Theodoros
    Psarras, Michalis
    Zygogianni, Anna
    Protopapa, Maria
    Kouloulias, Vassilis
    Platoni, Kalliopi
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (02)
  • [6] Dosimetric comparison of short and full arc in spinal PTV in volumetric-modulated arc therapy-based craniospinal irradiation
    Sarkar, Biplab
    Munshi, Anusheel
    Ganesh, Tharmarnadar
    Manikandan, Arjunan
    Mohanti, Bidhu K.
    MEDICAL DOSIMETRY, 2020, 45 (01) : 1 - 6
  • [7] Dosimetric comparison of volumetric modulated arc therapy and linear accelerator-based radiosurgery for the treatment of one to four brain metastases
    Salkeld, Alison L.
    Unicomb, Kylie
    Hayden, Amy J.
    Van Tilburg, Kevin
    Yau, Shan
    Tiver, Kenneth
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2014, 58 (06) : 722 - 728
  • [8] Volumetric-modulated arc therapy in craniospinal irradiation: a dosimetric analysis of acuros XB and analytical anisotropic algorithm comparing flattened and flattening filter-free beams with different energies
    Tamilarasu, Suresh
    Saminathan, Madeswaran
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (02) : 196 - 202
  • [9] Comparative Planning Analysis and Integral Dose of Volumetric Modulated Arc Therapy, Helical Tomotherapy, and Three-dimensional Conformal Craniospinal Irradiation for Pediatric Medulloblastoma
    Patel, Samir
    Drodge, Suzanne
    Jacques, Amanda
    Warkentin, Heather
    Powell, Kent
    Chafe, Susan
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (02) : 134 - 140
  • [10] Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: Plan quality and delivery time comparison with a C-arm linac
    Michiels, Steven
    Poels, Kenneth
    Crijns, Wouter
    Delombaerde, Laurence
    De Roover, Robin
    Vanstraelen, Bianca
    Haustermans, Karin
    Nuyts, Sandra
    Depuydt, Tom
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (03) : 479 - 484