Assessing privacy leakage in synthetic 3-D PET imaging using transversal GAN

被引:1
|
作者
Bergen, Robert V. [1 ]
Rajotte, Jean-Francois [1 ]
Yousefirizi, Fereshteh [2 ]
Rahmim, Arman [2 ,3 ]
Ng, Raymond T. [1 ]
机构
[1] Univ British Columbia, Data Sci Inst, Vancouver, BC V6T 1Z4, Canada
[2] BC Canc Res Inst, Dept Integrat Oncol, Vancouver, BC V5Z 1L3, Canada
[3] Univ British Columbia, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
PET; Synthetic; GAN; 3-D; Privacy;
D O I
10.1016/j.cmpb.2023.107910
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Training computer-vision related algorithms on medical images for disease diagnosis or image segmentation is difficult in large part due to privacy concerns. For this reason, generative image models are highly sought after to facilitate data sharing. However, 3-D generative models are understudied, and investigation of their privacy leakage is needed. Methods: We introduce our 3-D generative model, Transversal GAN (TrGAN), using head & neck PET images which are conditioned on tumor masks as a case study. We define quantitative measures of image fidelity and utility, and propose a novel framework for evaluating privacy-utility trade-off through membership inference attack. These metrics are evaluated in the course of training to identify ideal fidelity, utility and privacy tradeoffs and establish the relationships between these parameters. Results: We show that the discriminator of the TrGAN is vulnerable to attack, and that an attacker can identify which samples were used in training with almost perfect accuracy (AUC = 0.99). We also show that an attacker with access to only the generator cannot reliably classify whether a sample had been used for training (AUC = 0.51). We also propose and demonstrate a general decision procedure for any deep learning based generative model, which allows the user to quantify and evaluate the decision trade-off between downstream utility and privacy protection. Conclusions: TrGAN can generate 3-D medical images that retain important image features and statistical properties of the training data set, with minimal privacy loss as determined by a membership inference attack. Our utility-privacy decision procedure may be beneficial to researchers who wish to share data or lack a sufficient number of large labeled image datasets.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] 3-D Printed Microjet Impingement Cooling for Thermal Management of Ultrahigh-Power GaN Transistors
    Zhang, G.
    Pomeroy, J. W.
    Navarro, M. E.
    Cao, H.
    Kuball, M.
    Ding, Y.
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2021, 11 (05): : 748 - 754
  • [22] A feasibility study of the 3D fluorescent image reconstruction for the simultaneous PET and fluorescent CT Imaging system using depth of interaction PET detector
    Tashima, Hideaki
    Obi, Takashi
    Yamaya, Taiga
    Murayama, Hideo
    Kitamura, Keiji
    Oda, Ichiro
    Yamaguchi, Masahiro
    Ohyama, Nagaaki
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [23] Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound
    Filippou, Valeria
    Tsoumpas, Charalampos
    MEDICAL PHYSICS, 2018, 45 (09) : E740 - E760
  • [24] High precision axial coordinate readout for an axial 3-D PET detector module using a wave length shifter strip matrix
    Braem, A.
    Chesi, E.
    Joram, C.
    Seguinot, J.
    Weilhammer, P.
    De Leo, R.
    Nappi, E.
    Lustermann, W.
    Schinzel, D.
    Johnson, I.
    Renker, D.
    Albrecht, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03) : 1513 - 1521
  • [25] Enhancing Detail of 3D Terrain Models Using GAN
    Gorbatsevich, Vladimir
    Melnichenko, Mikhail
    Vygolov, Oleg
    MODELING ASPECTS IN OPTICAL METROLOGY VII, 2019, 11057
  • [26] Consumer perceptions on privacy and confidentiality in dermatology for 3D total-body imaging
    Horsham, Caitlin
    Janda, Monika
    Kerr, Melissa
    Soyer, H. Peter
    Caffery, Liam J.
    AUSTRALASIAN JOURNAL OF DERMATOLOGY, 2023, 64 (01) : 118 - 121
  • [27] Application of a spatially variant system model for 3-D whole-body pet image reconstruction
    Alessio, Adam M.
    Kinahan, Paul E.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1315 - 1318
  • [28] Assessment of 3-D PET quantitation: Influence of out of the field of view radioactive sources and of attenuating media
    Ferreira, NC
    Trebossen, R
    Bendriem, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1670 - 1675
  • [29] The value of F-18-fluorodeoxyglucose PET for the 3-D radiation treatment planning of malignant gliomas
    Gross, MW
    Weber, WA
    Feldmann, HJ
    Bartenstein, P
    Schwaiger, M
    Molls, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05): : 989 - 995
  • [30] 3D printing 18F radioactive phantoms for PET imaging
    Daniel Gillett
    Daniel Marsden
    Safia Ballout
    Bala Attili
    Nick Bird
    Sarah Heard
    Mark Gurnell
    Iosif A. Mendichovszky
    Luigi Aloj
    EJNMMI Physics, 8