Assessing privacy leakage in synthetic 3-D PET imaging using transversal GAN

被引:1
|
作者
Bergen, Robert V. [1 ]
Rajotte, Jean-Francois [1 ]
Yousefirizi, Fereshteh [2 ]
Rahmim, Arman [2 ,3 ]
Ng, Raymond T. [1 ]
机构
[1] Univ British Columbia, Data Sci Inst, Vancouver, BC V6T 1Z4, Canada
[2] BC Canc Res Inst, Dept Integrat Oncol, Vancouver, BC V5Z 1L3, Canada
[3] Univ British Columbia, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
PET; Synthetic; GAN; 3-D; Privacy;
D O I
10.1016/j.cmpb.2023.107910
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Training computer-vision related algorithms on medical images for disease diagnosis or image segmentation is difficult in large part due to privacy concerns. For this reason, generative image models are highly sought after to facilitate data sharing. However, 3-D generative models are understudied, and investigation of their privacy leakage is needed. Methods: We introduce our 3-D generative model, Transversal GAN (TrGAN), using head & neck PET images which are conditioned on tumor masks as a case study. We define quantitative measures of image fidelity and utility, and propose a novel framework for evaluating privacy-utility trade-off through membership inference attack. These metrics are evaluated in the course of training to identify ideal fidelity, utility and privacy tradeoffs and establish the relationships between these parameters. Results: We show that the discriminator of the TrGAN is vulnerable to attack, and that an attacker can identify which samples were used in training with almost perfect accuracy (AUC = 0.99). We also show that an attacker with access to only the generator cannot reliably classify whether a sample had been used for training (AUC = 0.51). We also propose and demonstrate a general decision procedure for any deep learning based generative model, which allows the user to quantify and evaluate the decision trade-off between downstream utility and privacy protection. Conclusions: TrGAN can generate 3-D medical images that retain important image features and statistical properties of the training data set, with minimal privacy loss as determined by a membership inference attack. Our utility-privacy decision procedure may be beneficial to researchers who wish to share data or lack a sufficient number of large labeled image datasets.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] 3-D PET Image Generation with tumour masks using TGAN
    Bergen, Robert, V
    Rajotte, Jean-Francois
    Yousefirizi, Fereshteh
    Klyuzhin, Ivan S.
    Rahmim, Arman
    Ng, Raymond T.
    MEDICAL IMAGING 2022: IMAGE PROCESSING, 2022, 12032
  • [2] Ultralow Leakage Current AlGaN/GaN Schottky Diodes With 3-D Anode Structure
    Matioli, Elison
    Lu, Bin
    Palacios, Tomas
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2013, 60 (10) : 3365 - 3370
  • [3] Quantification of Cerenkov Luminescence Imaging (CLI) Comparable With 3-D PET Standard Measurements
    Habte, Frezghi
    Natarajan, Arutselvan
    Paik, David S.
    Gambhir, Sanjiv Sam
    MOLECULAR IMAGING, 2018, 17
  • [4] Virtual clinical trials using 3D PET imaging
    Kinahan, Paul E.
    Byrd, Darrin
    Wangerin, Kristen
    Muzi, Mark
    Peterson, Lanell
    Kurland, Brenda
    Specht, Jennifer
    Linden, Hannah
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [5] Construction and tests of demonstrator modules for a 3-D axial PET system for brain or small animal imaging
    Beltrame, P.
    Bolle, E.
    Braem, A.
    Casella, C.
    Chesi, E.
    Clinthorne, N.
    Cochran, E.
    De Leo, R.
    Dissertori, G.
    Djambazov, G.
    Fanti, V.
    Honscheid, K.
    Huh, S.
    Johnson, I.
    Joram, C.
    Kagan, H.
    Lustermann, W.
    Meddi, F.
    Nappi, E.
    Nessi-Tedaldi, F.
    Oliver, J. F.
    Pauss, P.
    Rafecas, M.
    Renker, D.
    Rudge, A.
    Schinzel, D.
    Schneider, T.
    Seguinot, J.
    Smith, S.
    Solevi, P.
    Stapnes, S.
    Weilhammer, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 636 : S226 - S230
  • [6] Interior-point methodology for 3-D PET reconstruction
    Johnson, CA
    Seidel, J
    Sofer, A
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) : 271 - 285
  • [7] The 3-D alignment of objects in dynamic PET scans using filtered sinusoidal trajectories of sinogram
    Kostopoulos, Aristotelis E.
    Happonen, Anal P.
    Ruotsalainen, Ulla
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02) : 434 - 439
  • [8] Scatter modelling and correction strategies in fully 3-D PET
    Zaidi, H
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (11) : 1181 - 1184
  • [9] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [10] 3D-FRP: Direct fourier reconstruction with Fourier reprojection for fully 3-D PET
    Matej, S
    Lewitt, RM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1378 - 1385