Efficacy of Ahmed and Baerveldt glaucoma drainage device implantation in the pediatric population: A systematic review and meta-analysis

被引:10
|
作者
Stallworth, Jeannette Y. [1 ]
O'Brien, Kieran S. [1 ,2 ]
Han, Ying [1 ]
Oatts, Julius T. [1 ,3 ]
机构
[1] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
[2] Univ Calif San Francisco, Francis I Proctor Fdn, San Francisco, CA USA
[3] Univ Calif San Francisco, Dept Ophthalmol, 490 Illinois St, San Francisco, CA 94158 USA
关键词
Systematic review and meta-analysis; Glaucoma drainage device; Ahmed glaucoma valve; Baerveldt glaucoma implant; Childhood glaucoma; PRIMARY CONGENITAL GLAUCOMA; 1ST; 2; YEARS; VALVE IMPLANTATION; MITOMYCIN-C; SURGERY; OUTCOMES; TRABECULECTOMY; MANAGEMENT; POLYPROPYLENE; EXPERIENCE;
D O I
10.1016/j.survophthal.2023.01.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Glaucoma drainage devices (GDD) are increasingly utilized in the management of child-hood glaucoma. This systematic review and meta-analysis assesses the efficacy of first-time Ahmed or Baerveldt implantation in children. PubMed, Embase, and Cochrane Library were searched for relevant English-language, peer-reviewed literature. Postoperative outcomes were pooled using random effects regression models with restricted maximum likelihood estimation. Thirty-two studies (1,221 eyes, 885 children) were included. Mean & PLUSMN; standard deviation preoperative IOP was 31.8 & PLUSMN; 3.4 mm Hg. Pooled mean IOP at 12 and 24 months postoperatively were 16.5 mm Hg (95% CI, 15.5-17.6) and 17.6 mm Hg (95% CI, 16.4-18.7), respectively. Pooled proportions of success were 0.87 (95% CI, 0.83-0.91) at 12 months, 0.77 (95% CI, 0.71-0.83) at 24 months, 0.54 (95% CI, 0.44-0.65) at 48 months, 0.60 (95% CI, 0.48-0.71) at 60 months, and 0.37 (95% CI, 0.32-0.42) at 120 months. There were no differences in pro-portion of success at 12 and 24 months among eyes that received Ahmed and Baerveldt tube shunts, nor between eyes with primary glaucoma, glaucoma following cataract surgery, or other secondary glaucoma. Our findings show that Ahmed and Baerveldt shunts substan-tially reduced IOP for at least 24 months in childhood glaucoma, with similar findings among device types and glaucoma etiologies.& COPY; 2023 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
引用
收藏
页码:578 / 590
页数:13
相关论文
共 50 条
  • [1] Ahmed and Baerveldt Glaucoma Drainage Devices in Childhood Glaucoma: A Meta-Analysis
    Elhusseiny, Abdelrahman M.
    Hassan, Amr K.
    Azhari, Jamal O.
    Elkheniny, Fatmah D.
    Chauhan, Muhammad Z.
    Chang, Ta C.
    VanderVeen, Deborah K.
    Oke, Isdin
    Mansour, Munthir
    Pakravan, Mohammad
    Shaarawy, Tarek
    Sallam, Ahmed B.
    JOURNAL OF GLAUCOMA, 2023, 32 (08) : 686 - 694
  • [2] Ahmed to Baerveldt glaucoma drainage device exchange in pediatric patients
    Jacobson, Adam
    Bohnsack, Brenda L. L.
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [3] Ahmed to Baerveldt glaucoma drainage device exchange in pediatric patients
    Adam Jacobson
    Brenda L. Bohnsack
    BMC Ophthalmology, 23
  • [4] Ahmed glaucoma valve implant for refractory glaucoma in children: A systematic review and meta-analysis
    Fu, Xiangjun
    He, Juan
    Li, Guoliang
    Luo, Hongyi
    Peng, Ruijue
    Cheng, Yilian
    Peng, Jie
    Chen, Shiyan
    Qu, Chao
    SCIENCE PROGRESS, 2025, 108 (01)
  • [5] Comparison of the Ahmed glaucoma valve with the Baerveldt glaucoma implant: a meta-analysis
    Wang, Yi-Wen
    Wang, Ping-Bao
    Zeng, Chao
    Xia, Xiao-Bo
    BMC OPHTHALMOLOGY, 2015, 15
  • [6] Ahmed Versus Baerveldt Glaucoma Drainage Device in Uveitic Glaucoma: A Retrospective Comparative Study
    Sinha, Sapna
    Ganjei, Allen Y.
    McWatters, Zoe
    Lee, Daniel
    Moster, Marlene R.
    Myers, Jonathan S.
    Kolomeyer, Natasha
    Mantravadi, Anand V.
    Pro, Michael J.
    Razeghinejad, Reza
    JOURNAL OF GLAUCOMA, 2020, 29 (09) : 750 - 755
  • [7] Comparison of Ahmed Glaucoma Valve Implantation and Trabeculectomy for Glaucoma: A Systematic Review and Meta-Analysis
    Tan Haibo
    Kang Xin
    Lu ShiHeng
    Liu Lin
    PLOS ONE, 2015, 10 (02):
  • [8] Ahmed and baerveldt in glaucoma surgery: what is the safest choice? - a systematic review and meta-analysis
    Matarazzo, Francesco
    Passaro, Maria Laura
    Rinaldi, Michele
    Afflitto, Gabriele Gallo
    Aiello, Francesco
    Avolio, Fabio Claudio
    Aurilia, Alessandro
    Strianese, Diego
    Nucci, Carlo
    Costagliola, Ciro
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [9] The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a meta-analysis
    Wang, Shiming
    Gao, Xiaoming
    Qian, Nana
    BMC OPHTHALMOLOGY, 2016, 16
  • [10] Simultaneous Implantation of an Ahmed and Baerveldt Glaucoma Drainage Device for Uncontrolled Intraocular Pressure in Advanced Glaucoma
    Rao, Veena S.
    Christenbury, Joseph
    Lee, Paul
    Allingham, Rand
    Herndon, Leon
    Challa, Pratap
    JOURNAL OF GLAUCOMA, 2017, 26 (02) : 101 - 106