The effect of different kinematics on apical debris extrusion with a single-file system

被引:8
作者
Al Omari, Taher M. N. [1 ]
La Rosa, Giusy Rita Maria [2 ]
Albanna, Rami Haitham Issa [1 ]
Tabnjh, Abedelmalek [3 ]
Papale, Flavia [2 ]
Pedulla, Eugenio [2 ]
机构
[1] Jordan Univ Sci & Technol, Fac Dent, Dept Conservat Dent, Irbid, Jordan
[2] Univ Catania, Dept Gen Surg & Med Surg Specialties, Catania, Italy
[3] Jordan Univ Sci & Technol, Fac Appl Med Sci, Dept Appl Dent Sci, Irbid, Jordan
关键词
Adaptive motion; Canal pro Jeni; Debris extrusion; One Curve; Optimum Torque Reverse; OVAL ROOT CANALS; EXTRUDED DEBRIS; INSTRUMENTATION; IRRIGANT; STRAIGHT; PROTAPER; HAND;
D O I
10.1007/s10266-023-00802-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To compare the amount of extruded debris caused by different motions using a single-file system. Fifty mandibular first molar teeth were randomized into 5 groups (n = 10) according to the motion tested: Optimize Torque Reverse (OTR), TF Adaptive Motion (TFA), continuous rotation (CR), reciprocation motion (+ 150 degrees, -30 degrees) (REC), and Jeni motion (Jeni). One Curve single file 25/06 (Micro-Mega, Besancon, France) was used in all experimental groups. The root canals were irrigated with 2.5% NaOCl, and the extruded debris were collected at pre-weighted glass vials. The glass vials were kept inside an incubator for one week at 70 degrees C to dry out the irrigating solution. The extruded debris was quantified by subtracting the pre-instrumentation from the post-instrumentation weight of the glass vials. The time required for each instrumentation procedure was digitally recorded. All data were analyzed statistically with one way ANOVA and post hoc Tukey test (P < 0.05). All the motions extruded apically debris with Jeni mode caused significantly less debris extrusion than TFA, REC, and CR (P < 0.05) while no significant difference emerged with OTR. Preparation time was not significantly different in all groups. Within the limits of the present study, all the kinematics produced apically debris extrusion, with Jeni reporting a similar amount of debris compared with OTR and significantly less than TFA, REC, and CR. Preparation time was similar among the tested kinematics.
引用
收藏
页码:910 / 915
页数:6
相关论文
共 38 条
[21]   Evaluating In Vitro Performance of Novel Nickel-Titanium Rotary System (TruNatomy) Based on Debris Extrusion and Preparation Time from Severely Curved Canals [J].
Mustafa, Ruba ;
Al Oman, Taher ;
Al-Nasrawi, Suhad ;
Al Fodeh, Rami ;
Dkmak, Alaa ;
Haider, Julfikar .
JOURNAL OF ENDODONTICS, 2021, 47 (06) :976-981
[22]   A COMPARISON OF WEIGHTS OF DEBRIS EXTRUDED APICALLY BY CONVENTIONAL FILING AND CANAL MASTER TECHNIQUES [J].
MYERS, GL ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1991, 17 (06) :275-279
[23]   Kinematics of "Adaptive Motion" under Constant Torque Values [J].
Orhan, Ekim Onur ;
Bahadir, Duygu ;
Irmak, Ozgur .
JOURNAL OF ENDODONTICS, 2022, 48 (03) :355-361
[24]  
Panchal Veerale, 2019, J Indian Soc Pedod Prev Dent, V37, P75, DOI 10.4103/JISPPD.JISPPD_72_18
[25]   Apical debris extrusion during instrumentation of oval root canals in primary teeth using manual versus motorized files: an ex vivo study [J].
Pawar, Bhaggyashri A. ;
Pawar, Ajinkya M. ;
Atram, Jatin ;
Luke, Alexander Maniangat ;
Bhardwaj, Anuj ;
Kfir, Anda ;
Metzger, Zvi ;
Wahjuningrum, Dian Agustin .
SCIENTIFIC REPORTS, 2021, 11 (01)
[26]   Influence of continuous rotation or reciprocation of Optimum Torque Reverse motion on cyclic fatigue resistance of nickel-titanium rotary instruments [J].
Pedulla, E. ;
Corsentino, G. ;
Ambu, E. ;
Rovai, F. ;
Campedelli, F. ;
Rapisarda, S. ;
La Rosa, G. R. ;
Rapisarda, E. ;
Grandini, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (05) :522-528
[27]   Influence of kinematics and incidence angles on the cutting efficiency of two single-file nickel-titanium rotary instruments [J].
Pedulla, Eugenio ;
La Rosa, Giusy Rita Maria ;
Romano, Giuseppe ;
Leanza, Giuseppe ;
Rapisarda, Silvia ;
Isola, Gaetano ;
Ferlito, Sebastiano ;
Neelakantan, Prasanna ;
Generali, Luigi .
AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (01) :58-64
[28]   Retreatment of Experimental Carrier-Based Obturators with the Remover NiTi Instrument: Evaluation of Apical Extrusion and Effects of New Kinematics [J].
Pirani, Chiara ;
Iacono, Francesco ;
Zamparini, Fausto ;
Generali, Luigi ;
Prati, Carlo .
INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
[29]   Comparison of apical debris extrusion using clockwise and counter-clockwise single-file reciprocation of rotary and reciprocating systems [J].
Predin Djuric, Natasa ;
Van der Vyver, Peet ;
Vorster, Martin ;
Vally, Zunaid Ismail .
AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (03) :394-400
[30]   Comparison of OneShape, 2Shape and One Curve endodontic instruments for debris and irrigant extrusion [J].
Saricam, Esma ;
Kayaoglu, Guven .
DENTAL AND MEDICAL PROBLEMS, 2020, 57 (03) :255-259