Numerical Study on Local Scour Reduction around Two Cylindrical Piers Arranged in Tandem Using Collars

被引:3
作者
Qi, Hongliang [1 ]
Yuan, Tiangang [1 ,2 ]
Zou, Wen [3 ]
Tian, Weiping [1 ]
Li, Jiachun [1 ]
机构
[1] ChangAn Univ, Sch Highway, Minist Educ, Key Lab Special Area Highway Engn, Xian 710064, Peoples R China
[2] BYD Auto Ind Co Ltd, Automot Engn Res Inst, Xian 710199, Peoples R China
[3] Hexagon Software Technol Qingdao Co Ltd, Qingdao 266000, Peoples R China
关键词
piers in tandem; local scour depth; local scour reduction; collar; clear water; SCALE; DESIGN;
D O I
10.3390/w15234079
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Local scour occurring near bridge piers has become a major problem all over the world, which has caused countless bridge damage events. Explorations regarding local scour reduction measurements have become a research hotspot in the field. Much effective research has been conducted on scour reduction for single piers. However, studies on local scour reduction around multiple piers that are arranged in tandem have rarely been reported. Therefore, the effect of the span and the local scour reduction measurement (collar) on the characteristics of the local scouring behavior around two piers arranged in tandem are explored in this research, with numerical simulations in clear-water conditions. The results show that the local scour depth of the downstream pier increases gradually with an increase in the pier spacing, due to the weakened sheltering effect of the upstream pier. The local scouring of both the upstream and downstream piers can be reduced if the upstream pier is protected by a collar. The local scour reduction efficiency of the upstream pier can reach 52 similar to 55%. The local scour reduction efficiency of the downstream pier decreases rapidly from 84.3% to 8.3% with an increase in the pier spacing. If the pier spacing, G, is greater than 4.0D (D is the diameter of the pier), the local scour depth around the downstream pier is larger than that around the upstream pier. Therefore, if the local scour depth of the upstream pier is considered safe and acceptable, it is used as the reduction target of the downstream local scour depth. A collar must be adapted for use around the downstream pier when G/D > 4.0. If both the piers are protected by collars of the same size (W = 3.0D), the local scour reduction efficiency of the downstream pier is about 15% more than that of the upstream pier. The local scour depth around the downstream pier is 64.5% of that around the upstream pier. Therefore, the size of the collar around the downstream pier can be decreased to save costs. The local scour reduction efficiency for the downstream pier reduces from 66.7% to 39.8% when the downstream collar size (W) decreases from 3.0D to 2.0D. To ensure that the local scour depth around the downstream pier is no greater than that of the upstream pier, the downstream collar should be larger than 2.25D. These results can serve as a reference for the local scour reduction of two piers arranged in tandem.
引用
收藏
页数:21
相关论文
共 47 条
  • [11] [高虎 Gao Hu], 2022, [长江科学院院报, Journal of Yangtze River Scientific Research Institute], V39, P15
  • [12] [郭佳欣 Guo Jiaxin], 2021, [海洋湖沼通报, Transactions of Oceanology and Limnology], P84
  • [13] [侯志军 Hou Zhijun], 2021, [泥沙研究, Journal of Sediment Research], V46, P74
  • [14] Comparison between the circular and square collar in reduction of local scouring around bridge piers
    Khodashenas, Saeed Reza
    Shariati, Hossain
    Esmaeeli, Kazem
    [J]. NINTH INTERNATIONAL CONFERENCE ON FLUVIAL HYDRAULICS (RIVER FLOW 2018), 2018, 40
  • [15] Numerical investigation of local scour at two adjacent cylinders
    Kim, Hyung Suk
    Nabi, Mohamed
    Kimura, Ichiro
    Shimizu, Yasuyuki
    [J]. ADVANCES IN WATER RESOURCES, 2014, 70 : 131 - 147
  • [16] Kumar V., 1996, Ph.D. Thesis
  • [17] Liang F.Y., 2015, J. Hydraul. Eng, V46, P79
  • [18] Lin Z.F., 2023, China Rural Water Hydropower, V10, P9
  • [19] DESIGN METHOD FOR LOCAL SCOUR AT BRIDGE PIERS
    MELVILLE, BW
    SUTHERLAND, AJ
    [J]. JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1988, 114 (10): : 1210 - 1226
  • [20] Time scale for local scour at bridge piers
    Melville, BW
    Chiew, YM
    [J]. JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1999, 125 (01): : 59 - 65