The Diagnostic Value of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Differentiated Thyroid Cancer Patients with Elevated Thyroglobulin/Thyroglobulin Antibody Levels and Negative Iodine Scintigraphy: A Systematic Review and Meta-Analysis

被引:8
|
作者
Bang, Ji-In [1 ]
Park, Sohyun [2 ]
Kim, Keunyong [3 ,4 ,5 ]
Seo, Youngduk [6 ]
Chong, Ari [7 ]
Hong, Chae Moon [8 ]
Choi, Miyoung [9 ]
Lee, Sang-Woo [10 ,11 ]
Oh, So Won [12 ]
机构
[1] CHA Univ, CHA Bundang Med Ctr, Dept Nucl Med, Gyeonggi Do, South Korea
[2] Natl Canc Ctr Res Inst & Hosp, Dept Nucl Med, Gyeonggi Do, South Korea
[3] Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Nucl Med, Pusan, South Korea
[4] Pusan Natl Univ, Pusan Natl Univ Hosp, Biomed Res Inst, Pusan, South Korea
[5] Pusan Natl Univ, Sch Med, Pusan, South Korea
[6] Chungnam Natl Univ, Sejong Hosp, Dept Nucl Med, Sejong, South Korea
[7] Chosun Univ, Sch Med, Dept Nucl Med, Gwangju, South Korea
[8] Kyungpook Natl Univ, Sch Med, Dept Nucl Med, Daegu, South Korea
[9] Natl Evidence Based Healthcare Collaborating Agcy, Div Healthcare Technol Assessment Res, Seoul, South Korea
[10] Kyungpook Natl Univ, Sch Med, Dept Nucl Med, Daegu, South Korea
[11] Chilgok Hosp, Daegu, South Korea
[12] Seoul Natl Univ, Boramae Med Ctr, Dept Nucl Med, 20 Boramae Ro 5 Gil, Seoul 07061, South Korea
关键词
F-18-fluorodeoxyglucose; meta-analysis; positron emission tomography/computed tomography; thyroglobulin; thyroid cancer; WHOLE-BODY SCAN; HIGH SERUM THYROGLOBULIN; F-18 FDG PET/CT; TERM-FOLLOW-UP; ANTITHYROGLOBULIN ANTIBODY; CARCINOMA PATIENTS; TEST ACCURACY; RECURRENCE; PAPILLARY; F-18-FDG-PET;
D O I
10.1089/thy.2023.0264
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The objective of this study is to evaluate the diagnostic accuracy of F-18-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in detecting recurrence in patients with differentiated thyroid cancer (DTC) who have negative whole-body scans (WBSs) but elevated serum thyroglobulin (Tg) or thyroglobulin antibody (TgAb) levels.Methods: This systematic review/meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis for Diagnostic Test Accuracy criteria (International Prospective Register of Systematic Reviews registration number: CRD42022340924). A comprehensive search of the MEDLINE, EMBASE, and Cochrane databases identified articles reporting the diagnostic accuracy of FDG PET/CT for the detection of recurrence in patients with DTC with negative WBS and elevated serum Tg or TgAb levels published between January 2012 and June 2023. Meta-analyses were performed to determine the diagnostic accuracy of FDG PET/CT on the total target population as well as on subgroups stratified by serum Tg or TgAb, and thyrotropin (TSH) stimulation status at the time of FDG PET/CT. The Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) framework was applied to evaluate the quality of evidence and the strength of recommendations to facilitate translation of the meta-analysis results into practical recommendations for clinical guidelines.Results: A total of 24 studies involving 1988 patients were included for analysis. The overall pooled sensitivity and specificity values were 0.87 (95% confidence interval [CI] = 0.83-0.92; I-2 = 75%) and 0.84 (CI = 0.80-0.89; I-2 = 44%), respectively. Subgroup analyses revealed no significant differences in the diagnostic accuracy of FDG PET/CT in patients stratified by serum Tg or TgAb levels, and TSH stimulation status at the time of PET/CT. Treatment plans were changed following FDG PET/CT imaging in 40% (CI = 34-47%; I-2 = 39%) of cases. The quality level of evidence for using FDG PET/CT was moderate in both sensitivity and specificity according to the GRADE system.Conclusion: There is moderate quality evidence demonstrating the high diagnostic accuracy of FDG PET/CT in detecting recurrence in patients with DTC with negative WBS and elevated serum Tg or TgAb levels. This evidence corroborates the current guidelines' endorsement of FDG PET/CT as a diagnostic tool in such patients.
引用
收藏
页码:1224 / 1236
页数:13
相关论文
共 50 条
  • [1] Diagnostic accuracy of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in differentiated thyroid cancer patients with elevated thyroglobulin and negative 131I whole body scan: evaluation by thyroglobulin level
    Na, Sae Jung
    Yoo, Ie Ryung
    O, Joo Hyun
    Lin, Chenghe
    Lin, Qiuyu
    Kim, Sung Hoon
    Chung, Soo Kyo
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (01) : 26 - 34
  • [2] Diagnostic accuracy of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in differentiated thyroid cancer patients with elevated thyroglobulin and negative 131I whole body scan: evaluation by thyroglobulin level
    Sae Jung Na
    Ie Ryung Yoo
    Joo Hyun O
    Chenghe Lin
    Qiuyu Lin
    Sung Hoon Kim
    Soo Kyo Chung
    Annals of Nuclear Medicine, 2012, 26 : 26 - 34
  • [3] Clinical Determinants of Fluorodeoxyglucose Positron Emission Tomography/ Computed Tomography in Differentiated Thyroid Cancer Patients with Elevated Thyroglobulin and Negative (131)Iodine Whole Body Scans after (131)Iodine Therapy
    Shamim, Syed Ejaz
    Nang, Lee Boon
    Shuaib, Ibrahim Lutfi
    Muhamad, Nor Asiah
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2014, 21 (03): : 38 - 46
  • [4] Positron emission tomography-computed tomography with 18F-fluorodeoxyglucose in patients with recurrent differentiated thyroid carcinoma and negative radioiodine scan. Diagnostic performance and relation with tyroglobulin levels
    Mariscal Labrador, E.
    Garcia Burillo, A.
    Castell-Conesa, J.
    Obiols Alfonso, G.
    Kisiel Gonzalez, N.
    Barios Profitos, M.
    Aguade-Bruix, S.
    Mesa Manteca, J.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2013, 32 (03): : 146 - 151
  • [5] What is the role of florine-18 fluorodeoxyglucose/positron emission tomography/computed tomography imaging in well-differentiated thyroid cancers with negative iodine-131 scan high thyroglobulin and normal anti-thyroglobulin levels
    Doner, Rana Kaya
    Sager, Sait
    Gortan, Fatma Arzu
    Topuz, Ozge Vural
    Akyel, Resit
    Vatankulu, Betul
    Baran, Ahmet
    Teksoz, Serkan
    Sonmezoglu, Kerim
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2016, 12 (02) : 1010 - 1017
  • [6] Prognostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography at diagnosis in untreated multiple myeloma patients: a systematic review and meta-analysis
    Qian Li
    Linhui Hu
    Alice Charwudzi
    Weiwei Zhu
    Ye Meng
    Zhimin Zhai
    Clinical and Experimental Medicine, 2023, 23 : 31 - 43
  • [7] Prognostic value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography at diagnosis in untreated multiple myeloma patients: a systematic review and meta-analysis
    Li, Qian
    Hu, Linhui
    Charwudzi, Alice
    Zhu, Weiwei
    Meng, Ye
    Zhai, Zhimin
    CLINICAL AND EXPERIMENTAL MEDICINE, 2023, 23 (01) : 31 - 43
  • [8] Role of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in patients affected by differentiated thyroid carcinoma, high thyroglobulin level, and negative 131I scan: review of the literature
    Bertagna, Francesco
    Biasiotto, Giorgio
    Orlando, Emanuela
    Bosio, Giovanni
    Giubbini, Raffaele
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (09) : 629 - 636
  • [9] Role of Thyroglobulin Doubling Time in Differentiated Thyroid Cancer and Its Relationship with Demographic-Histopathologic Risk Factors and 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Parameters
    Araz, Mine
    Soydal, Cigdem
    Ozkan, Elgin
    Akkus, Pinar
    Nak, Demet
    Kucuk, N. Ozlem
    Kir, K. Metin
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2021, 36 (05) : 425 - 432
  • [10] Diagnostic value of positron emission tomography/computed tomography with fluorine-18 fluordeoxyglucose in patients with differentiated thyroid gland carcinoma, high thyroglobulin serum levels and negative iodine whole body scan
    Yamaga, Lilian Yuri Itaya
    da Cunha, Marcelo Livorsi
    Wagner, Jairo
    Thom, Annelise Fischer
    Daniel, Mauro Miguel
    de Gusmao Funari, Marcao B.
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2007, 51 (04) : 581 - 586