Technical note: Semiautomated targeted postmortem computed tomography angiography of the pulmonary arteries using a robotic system

被引:4
作者
Franckenberg, Sabine [1 ,2 ]
Sieberth, Till [1 ]
Ptacek, Wolfgang [3 ]
Fuerst, Martin [3 ]
Colacicco, Giovanni [4 ]
Ebert, Lars [1 ]
机构
[1] Univ Zurich, Inst Forens Med, Dept Forens Med & Imaging, Zurich, Switzerland
[2] Univ Hosp Zurich, Dept Diagnost & Intervent Radiol, Raemistr 100, Zurich CH-8091, Switzerland
[3] Austrian Ctr Med Innovat & Technol ACMIT GmbH, Wiener Neustadt, Austria
[4] Univ Zurich, Inst Anat, Zurich, Switzerland
关键词
Virtobot; Postmortem computed tomography; angiography; Pulmonary embolism; Pulmonary artery; VIRTUAL AUTOPSY; VIRTOPSY; VIRTOBOT;
D O I
10.1016/j.forsciint.2023.111712
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Introduction: To better depict vascular lesions on postmortem computed tomography (PMCT), whole-body postmortem computed tomography angiography (PMCTA) can be used in forensic diagnostics. Targeted angiography, in which only a specific vessel is filled with contrast agent, might help in cases of traumatic changes that render whole-body PMCTA impossible. Moreover, in targeted PMCTA, the contrast agent does not affect the haptics of any other organs. In this article, we describe automated, CT-guided targeted an-giography of the pulmonary artery (PA) using the Virtobot system. Material and methods: Our study group consisted of 8 deceased persons (3 males, 5 females). We first performed an unenhanced CT scan and used the data obtained to plan the needle trajectories with the Virtobot planning software. Then, the needle was fully automatically placed by the Virtobot system. Subsequently, 50 ml of contrast agent was injected manually, and the CT scan was repeated (targeted PMCTA).Results and discussion: We tested a new method for performing semiautomated targeted postmortem an-giography of the PAs using a robotic needle placement system (Virtobot). In 6 out of our 8 cases, the in-jection of contrast agent in the PA was successful. In five of the six successful cases, there was reflux of contrast agent to some extent, but the reflux did not affect the readout. In general, the procedure was easy to plan based on a PMCT data set, and the pulmonary trunk was easy to reach with a robotic needle placement system.(c) 2023 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http:// creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:5
相关论文
共 14 条
[1]  
Ampanozi G., 2019, INT J LEGAL MED
[2]   Postmortem Imaging: An Update [J].
Cafarelli, Francesco Pio ;
Grilli, Gianpaolo ;
Zizzo, Giulio ;
Bertozzi, Giuseppe ;
Giuliani, Nicola ;
Mahakkanukrauh, Pasuk ;
Pinto, Antonio ;
Guglielmi, Giuseppe .
SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (01) :86-93
[3]   VIRTOPSY: Minimally invasive, imaging-guided virtual autopsy [J].
Dirnhofer, Richard ;
Jackowski, Christian ;
Vock, Peter ;
Potter, Kimberlee ;
Thali, Michael J. .
RADIOGRAPHICS, 2006, 26 (05) :1305-1333
[4]   Virtobot 2.0: the future of automated surface documentation and CT-guided needle placement in forensic medicine [J].
Ebert, Lars Christian ;
Ptacek, Wolfgang ;
Breitbeck, Robert ;
Fuerst, Martin ;
Kronreif, Gernot ;
Martinez, Rosa Maria ;
Thali, Michael ;
Flach, Patricia M. .
FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2014, 10 (02) :179-186
[5]   Virtobot - a multi-functional robotic system for 3D surface scanning and automatic post mortem biopsy [J].
Ebert, Lars Christian ;
Ptacek, Wolfgang ;
Naether, Silvio ;
Fuerst, Martin ;
Ross, Steffen ;
Buck, Ursula ;
Weber, Stefan ;
Thali, Michael .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2010, 6 (01) :18-27
[6]   Advances in post-mortem CT-angiography [J].
Grabherr, S. ;
Grimm, J. ;
Dominguez, A. ;
Vanhaebost, J. ;
Mangin, P. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036)
[7]   Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study [J].
Grabherr, Silke ;
Heinemann, Axel ;
Vogel, Hermann ;
Rutty, Guy ;
Morgan, Bruno ;
Wozniak, Krzysztof ;
Dedouit, Fabrice ;
Fischer, Florian ;
Lochner, Stefanie ;
Wittig, Holger ;
Guglielmi, Giuseppe ;
Eplinius, Franziska ;
Michaud, Katarzyna ;
Palmiere, Cristian ;
Chevallier, Christine ;
Mangin, Patrice ;
Grimm, Jochen M. .
RADIOLOGY, 2018, 288 (01) :270-276
[8]   The utility of postmortem computed tomography selective coronary angiography in parallel with autopsy [J].
Inokuchi, Go ;
Yajima, Daisuke ;
Hayakawa, Mutsumi ;
Motomura, Ayumi ;
Chiba, Fumiko ;
Torimitsu, Suguru ;
Makino, Yohsuke ;
Iwase, Hirotaro .
FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2013, 9 (04) :506-514
[9]   Detection of coronary thrombosis after multi-phase postmortem CT-angiography [J].
Palmiere, Cristian ;
Lobrinus, Johannes Alexander ;
Mangin, Patrice ;
Grabherr, Silke .
LEGAL MEDICINE, 2013, 15 (01) :12-18
[10]   Evaluation of an acetated Ringer -based contrast material mixture for postmortem computed tomography angiography [J].
Peporte, A. R. J. ;
Gascho, D. ;
Stamou, S. ;
Bensler, S. ;
Thali, M. J. ;
Leschka, S. ;
Flach, P. M. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (7-8) :489-497