Experimental study on low temperature heating performance of different vapor injection heat pump systems equipped with a flash tank and economizers for electric vehicle

被引:15
作者
Li, Kang [1 ,2 ]
Ma, Jingru [1 ]
Zhang, Bin [1 ]
Su, Lin [1 ]
Liu, Ni [1 ]
Zhang, Hua [1 ]
Dou, Binlin [1 ]
He, Qize [4 ]
Zhou, Xuejin [3 ]
Tu, Ran [3 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Key Lab Multiphase Flow & Heat Transfer Shanghai P, Shanghai 200093, Peoples R China
[3] Huaqiao Univ, Coll Mech Engn & Automat, Xiamen 361021, Fujian, Peoples R China
[4] Shanghai Fire Res Inst MEM, Shanghai 200032, Peoples R China
关键词
Vapor injection; Electric vehicle; Flash tank; Economizer; Upstream and downstream injection; COLD CLIMATE; R134A;
D O I
10.1016/j.applthermaleng.2023.120428
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of the most promising solutions is applying vapor injection technology to improve the heating performance of air conditioning heat pump systems in electric vehicles operating at extremely low temperatures. This study examined the effects of employing flash tank vapor injection (FVI) and economizer vapor injection (EVI) with both upstream injection (UI) path and downstream injection (DI) path configurations on a vapor injection heat pump system with a small ratio vapor injection scroll compressor. Experiments were conducted to record the system performance at low temperatures, and typical heat transfer characteristics were obtained with different expansion valve opening degrees and compressor speeds. The influence of the injection pressure on the system performance was also investigated, and the optimal injection pressure was determined. The results for the up-stream injection, downstream injection and flash tank vapor injection systems indicated maximum increases in the system's heating capacity of 19.7 %, 22.6 %, and 92.3 %, and in its coefficient of performance (COP) of 24.2 %, 16.9 %, and 118 %, respectively; the corresponding discharge temperatures decreased by 12.4 degrees C, 18.99 degrees C, and 16.95 degrees C, respectively. In addition, the optimal injection pressure was determined according to the maximum value of COP, and the optimal injection pressure range for the system is 0.16-0.37 MPa. Hence, a vapor injection system using an economizer with a downstream path could achieve better heating performance at relatively low temperatures. In contrast, a flash tank would offer some heating capacity advantages at temperatures below-15 degrees C.
引用
收藏
页数:11
相关论文
共 25 条
[1]  
Bang S., 2008, P VDA ALT REFR WINT
[2]   Effects of injection-port angle and internal heat exchanger length in vapor injection heat pumps for electric vehicles [J].
Jung, Jongho ;
Jeon, Yongseok ;
Cho, Wonhee ;
Kim, Yongchan .
ENERGY, 2020, 193 :599-607
[3]   Heating performance of a VRF heat pump system incorporating double vapor injection in scroll compressor [J].
Kang, Donghoon ;
Jeong, Ji Hwan ;
Ryu, Byoungjin .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 96 :50-62
[4]   Performance comparison among two-phase, liquid, and vapor injection heat pumps with a scroll compressor using R410A [J].
Kim, Dongwoo ;
Jeon, Yongseok ;
Jang, Dong Soo ;
Kim, Yongchan .
APPLIED THERMAL ENGINEERING, 2018, 137 :193-202
[5]   Performance evaluation of a vapor injection heat pump system for electric vehicles [J].
Kwon, Chunkyu ;
Kim, Mo Se ;
Choi, Younguk ;
Kim, Min Soo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 :138-150
[6]   A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications [J].
Lee, Yohan ;
Jung, Dongsoo .
APPLIED THERMAL ENGINEERING, 2012, 35 :240-242
[7]  
Li WY, 2020, INT J REFRIG, V120, P1
[8]   Experimental study of a heat pump system with flash-tank coupled with scroll compressor [J].
Ma Guo-Yuan ;
Zhao Hui-Xia .
ENERGY AND BUILDINGS, 2008, 40 (05) :697-701
[9]   Traffic impacts on energy consumption of electric and conventional vehicles [J].
Mamarikas, Sokratis ;
Doulgeris, Stylianos ;
Samaras, Zissis ;
Ntziachristos, Leonidas .
TRANSPORTATION RESEARCH PART D-TRANSPORT AND ENVIRONMENT, 2022, 105
[10]   Performance limit for economized cycles with continuous refrigerant injection [J].
Mathison, Margaret M. ;
Braun, James E. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :234-242