Technical Trick: Supplemental Medial Column Screw Fixation of Distal Femur Fractures Treated With a Laterally Based Locked Plate

被引:4
作者
Chen, Stephen R. [1 ]
Shaikh, Humza [1 ]
Turvey, Blake R. [1 ]
Moloney, Gele B. [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Dept Orthopaed Surg, 3471 Fifth Ave, Pittsburgh, PA 15213 USA
关键词
periprosthetic distal femur fracture; distal femur fracture; INVASIVE STABILIZATION SYSTEM; FEMORAL FRACTURES; DUAL-PLATE; INTRAMEDULLARY NAIL; INTERNAL-FIXATION; FAILURE;
D O I
10.1097/BOT.0000000000002475
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Given known failure rates after lateral plating of distal femur fractures, there is an increasing interest in augmenting fixation to improve outcomes. The addition of medial plates or intramedullary nails have been described with promising results, decreasing nonunion and varus collapse rates. However, the use of dual implants increases implant costs, adds surgical complexity, and requires a second surgical approach that may increase morbidity. A supplemental, percutaneously placed, medial column screw may provide a less invasive means of improving stability and achieving fracture union compared with lateral plating alone.
引用
收藏
页码:E175 / E180
页数:6
相关论文
共 30 条
[1]   Dual plate fixation results in improved union rates in comminuted distal femur fractures compared to single plate fixation [J].
Bologna, Matthew Gregory ;
Claudio, Mariano Garay ;
Shields, Kelly J. ;
Katz, Curren ;
Salopek, Traci ;
Westrick, Edward Ryan .
JOURNAL OF ORTHOPAEDICS, 2020, 18 :76-79
[2]   Failure of less invasive stabilization system plates in the distal femur - A report of four cases [J].
Button, G ;
Wolinsky, P ;
Hak, D .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :565-570
[3]   Comparative biomechanical analysis of supracondylar femur fracture fixation: Locked intramedullary nail versus 95-degree angled plate [J].
David, SM ;
Harrow, ME ;
Peindl, RD ;
Frick, SL ;
Kellam, JF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (05) :344-350
[4]  
Davison Brian L, 2003, Am J Orthop (Belle Mead NJ), V32, P27
[5]   Supplementation of Lateral Locked Plating for Distal Femur Fractures: A Biomechanical Study [J].
Fontenot, Philip B. ;
Diaz, Miguel ;
Stoops, Kyle ;
Barrick, Brett ;
Santoni, Brandon ;
Mir, Hassan .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (12) :642-648
[6]   Results of polyaxial locked-plate fixation of periarticular fractures of the knee [J].
Haidukewych, George ;
Sems, Stephen A. ;
Huebner, David ;
Horwitz, Daniel ;
Levy, Bruce .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03) :614-620
[7]   Retrograde nailing versus fixed-angle blade plating for supracondylar femoral fractures: A randomized controlled trial [J].
Hartin, NL ;
Harris, I ;
Hazratwala, K .
ANZ JOURNAL OF SURGERY, 2006, 76 (05) :290-294
[8]   Locking Plates for Distal Femur Fractures: Is There a Problem With Fracture Healing? [J].
Henderson, Christopher E. ;
Kuhl, Lori L. ;
Fitzpatrick, Daniel C. ;
Marsh, J. L. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 :S8-S14
[9]   Outcome of periprosthetic distal femoral fractures following knee arthroplasty [J].
Hoffmann, M. F. ;
Jones, C. B. ;
Sietsema, D. L. ;
Koenig, S. J. ;
Tornetta, P., III .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07) :1084-1089
[10]   Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort [J].
Hoffmann, Martin F. ;
Jones, Clifford B. ;
Sietsema, Debra L. ;
Tornetta, Paul, III ;
Koenig, Scott J. .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2013, 8