Effect of decreased contrast injection flow rate on aortic enhancement in 80-KV peak CT with contrast dose reduction

被引:0
作者
Morisaka, Hiroyuki [1 ,2 ]
Matsuura, Koichiro [2 ]
Yamaguchi, Haruomi [3 ]
Ichikawa, Tomoaki [4 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo, Yamanashi 4093898, Japan
[2] Saitama Med Univ, Diagnost Radiol, Int Med Ctr, Hidaka, Saitama, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo, Japan
[4] Gunma Univ, Dept Diagnost Radiol & Nucl Med, Grad Sch Med, Maebashi, Gunma, Japan
关键词
Aortic enhancement; computed tomography; flow rate; iodine contrast agent; LOW-TUBE-VOLTAGE; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; IODINE; PROTOCOLS; ARTERIAL; VOLUME;
D O I
10.1177/02841851211067144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Effect of decreased injection flow rate of contrast agent at the same iodine dose and delivery rate on aortic enhancement has not been clearly elucidated. Purpose To evaluate the effect of decreased injection flow rate of contrast agent on aortic peak enhancement in a dynamic flow phantom and on aortic enhancement in clinical dynamic 80-kVp computed tomography (CT) with contrast dose reduction. Material and Methods In the dynamic flow phantom experiment, the effect of a decreased injection flow rate at the same total iodine dose and delivery rate on simulated aortic peak enhancement was evaluated. In the clinical retrospective study, we searched 312 patients with renal dysfunction who underwent an 80-kVp abdominal dynamic CT with 40% reduction of contrast agent from a standard 120-kVp protocol and measured the aortic enhancement at the level of the hepatic hilum. Independent predictors for aortic enhancement were determined by multiple linear regression analysis, and after adjustment of significant predictors, independent variables for acquiring optimal aortic enhancement, >= 300 HU, were determined by multiple logistic regression analysis. Results In the phantom experiment, decreased flow rate showed a significant but small descent effect (6%-9%) on simulated aortic peak enhancement. In the multiple linear regression analysis, only age was an independent predictor of aortic enhancement; there was no independent predictor for optimal age-adjusted aortic enhancement of >= 300 HU. Conclusions Decreased injection flow rate had a small influence on aortic enhancement in vitro but had no significant effect on the aortic enhancement in clinical dynamic 80-kVp CT.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 26 条
  • [1] Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT: Phantom and patient studies
    Awai K.
    Nakayama Y.
    Nakaura T.
    Yanaga Y.
    Tamura Y.
    Hatemura M.
    Funama Y.
    Yamashita Y.
    [J]. Radiation Medicine, 2007, 25 (1): : 14 - 21
  • [2] Scan time adapted contrast agent injection protocols with low volume for low- tube voltage CT angiography: An in vitro study
    Benz, Matthias R.
    Szucs-Farkas, Zsolt
    Froehlich, Johannes M.
    Stadelmann, Geraldine
    Bongartz, Georg
    Bouwman, Luc
    Schindera, Sebastian T.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 65 - 69
  • [3] Computed Tomographic Venography for Varicose Veins of the Lower Extremities: Prospective Comparison of 80-kVp and Conventional 120-kVp Protocols
    Cho, Eun-Suk
    Kim, Joo Hee
    Kim, Sungjun
    Yu, Jeong-Sik
    Chung, Jae-Joon
    Yoon, Choon-Sik
    Lee, Hyeon-Kyeong
    Lee, Kyung Hee
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 583 - 590
  • [4] Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation
    Deinzer, Christoph K. W.
    Danova, Daniela
    Kleb, Beate
    Klose, Klaus J.
    Heverhagen, Johannes T.
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2014, 9 (04) : 259 - 267
  • [5] Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography A Systematic Preclinical Approach
    Fleischmann, Ulrike
    Pietsch, Hubertus
    Korporaal, Johannes G.
    Flohr, Thomas G.
    Uder, Michael
    Jost, Gregor
    Lell, Michael M.
    [J]. INVESTIGATIVE RADIOLOGY, 2018, 53 (05) : 264 - 270
  • [6] Minimally Required Iodine Dose for the Detection of Hypervascular Hepatocellular Carcinoma on 80-kVp CT
    Goshima, Satoshi
    Kanematsu, Masayuki
    Noda, Yoshifumi
    Kawai, Nobuyuki
    Kawada, Hiroshi
    Ono, Hiromi
    Bae, Kyongtae T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (03) : 518 - 525
  • [7] Triple-Rule-Out CT Angiography for Evaluation of Acute Chest Pain and Possible Acute Coronary Syndrome
    Halpern, Ethan J.
    [J]. RADIOLOGY, 2009, 252 (02) : 332 - 345
  • [8] Enhanced radiation dose and DNA damage associated with iodinated contrast media in diagnostic X-ray imaging
    Harbron, Richard
    Ainsbury, Elizabeth A.
    Bouffler, Simon D.
    Tanner, Rick J.
    Eakins, Jonathan S.
    Pearce, Mark S.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1079)
  • [9] Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 941 - 947
  • [10] MDCT angiography of the pulmonary arteries:: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates
    Keil, S.
    Plumhans, C.
    Behrendt, F. F.
    Das, M.
    Stanzel, S.
    Muehlenbruch, G.
    Seidensticker, P.
    Knackstedt, C.
    Mahnken, A. H.
    Guenther, R. W.
    Wildberger, J. E.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (08) : 1690 - 1695